Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Risk Factors for and Prediction by Caregivers of Extubation Failure in ICU Patients: A Prospective Study*

Thille, Arnaud W., Boissier, Florence, Ben Ghezala, Hassen, Razazi, Keyvan, Mekontso-Dessap, Armand, Brun-Buisson, Christian·2015·Critical Care Medicine

Abstract

OBJECTIVE: The influence of delirium, ICU-acquired paresis, and cardiac performance on extubation outcome has never been evaluated together. We aimed to assess the respective role of these factors on the risk of extubation failure and to assess the predictive accuracy of caregivers. DESIGN AND SETTING: Prospective observational study of all planned extubations in a 13-bed medical ICU of a teaching hospital. INTERVENTIONS: On the day of extubation, muscle strength of the four limbs, criteria for delirium, cardiac performance, cough strength, and the risk of extubation failure predicted by caregivers were prospectively assessed. Extubation failure was defined as the need for reintubation within the following 7 days. MEASUREMENTS AND MAIN RESULTS: Over the 18-month study period, 533 patients required intubation. Among the 225 patients intubated for more than 24 hours who experienced a planned extubation attempt, 31 patients (14%) required reintubation within the 7 days following extubation. In multivariate analysis, duration of mechanical ventilation more than 7 days prior to extubation, ineffective cough, and severe systolic left ventricular dysfunction were the three independent factors associated with extubation failure. Although patients considered at high risk for extubation failure had higher reintubation rate, prediction of extubation failure by caregivers at time of extubation had high specificity but low sensitivity. CONCLUSIONS: An ineffective cough, a prior duration of mechanical ventilation more than 7 days, and severe systolic left ventricular dysfunction were stronger predictors of extubation failure than delirium or ICU-acquired weakness. Only one-third patients who required reintubation were considered at high risk for extubation failure by caregivers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000000748

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 261

Metadata

Authors
Thille, A. W., Boissier, F., Ben Ghezala, H., Razazi, K., Mekontso-Dessap, A., & Brun-Buisson, C.
Venue
Critical Care Medicine
Published
2015-03
Volume
43
Issue
3
Pages
613-620
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2080371643
Cited by
261
References
38
FWCI
9.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Risk Factors for and Prediction by Caregivers of Extubation Failure in ICU Patients: A Prospective Study*. https://app.cochat.ai/papers/10.1097/ccm.0000000000000748
The paper
Thille, A. W., Boissier, F., Ben Ghezala, H., Razazi, K., Mekontso-Dessap, A., & Brun-Buisson, C. (2015). Risk Factors for and Prediction by Caregivers of Extubation Failure in ICU Patients: A Prospective Study*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000000748

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.