Arterial Pulse Pressure Variation with Mechanical Ventilation
The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
Fluid administration leads to a significant increase in cardiac output in only half of ICU patients. This has led to the concept of assessing fluid responsiveness before infusing fluid. Pulse pressure variation (PPV), which quantifies the changes in arterial pulse pressure during mechanical ventilation, is one of the dynamic variables that can predict fluid responsiveness. The underlying hypothesis is that large respiratory changes in left ventricular stroke volume, and thus pulse pressure, occur in cases of biventricular preload responsiveness. Several studies showed that PPV accurately predicts fluid responsiveness when patients are under controlled mechanical ventilation. Nevertheless, in many conditions encountered in the ICU, the interpretation of PPV is unreliable (spontaneous breathing, cardiac arrhythmias) or doubtful (low Vt). To overcome some of these limitations, researchers have proposed using simple tests such as the Vt challenge to evaluate the dynamic response of PPV. The applicability of PPV is higher in the operating room setting, where fluid strategies made on the basis of PPV improve postoperative outcomes. In medical critically ill patients, although no randomized controlled trial has compared PPV-based fluid management with standard care, the Surviving Sepsis Campaign guidelines recommend using fluid responsiveness indices, including PPV, whenever applicable. In conclusion, PPV is useful for managing fluid therapy under specific conditions where it is reliable. The kinetics of PPV during diagnostic or therapeutic tests is also helpful for fluid management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rudski, L. G., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,049
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621 · cited 13×
“individualization of hemodynamic therapy and occupies a major place in guiding resuscitation of ICU patients today (8, 9).”
BackgroundMethodInfluentialSepsis in European intensive care units: Results of the SOAP study*
Vincent, J.-L., Sakr, Y., Sprung, C. L., Ranieri, V. M., Reinhart, K., Gerlach, H., Moreno, R., Carlet, J., Le Gall, J.-R., & Payen, D. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000194725.48928.3a · Cited by 2,836 · cited 1×
“Nevertheless, given that fluid overload may cause harm to ICU patients (11), particularly to fluid non-responders (12), it is important to detect fluid responsiveness before administering any fluid.”
BackgroundThe Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · Chest · doi:10.1378/chest.07-2800 · Cited by 2,068 · cited 1×
“In cases where the risks of lung edema are not negligible, additional variables, such as extravascular lung water (74) or the presence of B-lines on lung ultrasound examination (75), are useful in making the appropriate decision.”
BackgroundCecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Self-citationFan, E., Del Sorbo, L., Goligher, E. C., Hodgson, C. L., Munshi, L., Walkey, A. J., Adhikari, N. K. J., Amato, M. B. P., Branson, R., Brower, R. G., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0548st · Cited by 1,630
Elevation of Systemic Oxygen Delivery in the Treatment of Critically Ill Patients
Hayes, M. A., Timmins, A. C., Yau, E., Palazzo, M., Hinds, C. J., & Watson, D. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406163302404 · Cited by 1,538 · cited 1×
“The factors that contributed to this decline are multiple, including the publication of randomized controlled trials that showed either no benefit (2) or even deleterious effects (3) of strategies aimed at maximizing oxygen delivery in the intensive care unit (ICU) patients.”
BackgroundA Trial of Goal-Oriented Hemodynamic Therapy in Critically Ill Patients
Gattinoni, L., Brazzi, L., Pelosi, P., Latini, R., Tognoni, G., Pesenti, A., & Fumagalli, R. (1995) · New England Journal of Medicine · doi:10.1056/nejm199510193331601 · Cited by 1,510
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458 · cited 11×
“Accordingly, we showed that PPV was a better predictor of fluid responsiveness than SPV (24).”
BackgroundInfluentialSelf-citationPredicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Self-citationMarik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272 · cited 5×
“It is noteworthy that in the studies included, fluid responsiveness was defined using either one of the following techniques: thermodilution, transpulmonary thermodilution, pulse contour analysis, or esophageal Doppler (20).”
BackgroundMethodInfluentialHarvey, S., Harrison, D. A., Singer, M., Ashcroft, J., Jones, C. M., Elbourne, D., Brampton, W., Williams, D., Young, D., & Rowan, K. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67061-4 · Cited by 1,126
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967 · cited 1×
“The respiratory changes in ultrasound variables such as the velocity time-integral (VTI) of the LV outflow track (echocardiography) (38), the aortic blood flow (esophageal Doppler) (39), the diameter of the inferior (40) or superior vena cava (41) and the diameter of the internal jugular vein (42) have been shown to b…”
BackgroundSelf-citationPassive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952 · cited 1×
“In such cases, PPV cannot predict fluid responsiveness (51), since the respiratory changes in intrathoracic pressure are irregular, either in rate or in amplitude.”
BackgroundSelf-citationMarik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612 · cited 1×
“The respiratory changes in ultrasound variables such as the velocity time-integral (VTI) of the LV outflow track (echocardiography) (38), the aortic blood flow (esophageal Doppler) (39), the diameter of the inferior (40) or superior vena cava (41) and the diameter of the internal jugular vein (42) have been shown to b…”
BackgroundSelf-citationPrediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600 · cited 2×
“Nevertheless, given that fluid overload may cause harm to ICU patients (11), particularly to fluid non-responders (12), it is important to detect fluid responsiveness before administering any fluid.”
BackgroundSelf-citationFluid challenges in intensive care: the FENICE study: A global inception cohort study
on behalf of the FENICE Investigators and the ESICM Trial Group, Cecconi, M., Hofer, C., Teboul, J.-L., Pettila, V., Wilkman, E., Molnar, Z., Della Rocca, G., Aldecoa, C., Artigas, A., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3850-x · Cited by 573
Self-citationSystolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension
Tavernier, B., Makhotine, O., Lebuffe, G., Dupont, J., & Scherpereel, P. (1998) · Anesthesiology · doi:10.1097/00000542-199812000-00007 · Cited by 570
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554 · cited 1×
“between 9 and 13%) where no conclusion can be drawn about fluid responsiveness, even when tidal volume is ≥ 8mL/kg (71).”
BackgroundSuperior vena caval collapsibility as a gauge of volume status in ventilated septic patients
Vieillard-Baron, A., Chergui, K., Rabiller, A., Peyrouset, O., Page, B., Beauchet, A., & Jardin, F. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2361-y · Cited by 476
Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans
Chemla, D., Hébert, J.-L., Coirault, C., Zamani, K., Suard, I., Colin, P., & Lecarpentier, Y. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.2.h500 · Cited by 462 · cited 1×
“7 Aortic pulse pressure (systolic pressure minus diastolic pressure) is directly proportional to LV stroke volume and inversely related to aortic compliance (22).”
BackgroundSelf-citationStroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00034 · Cited by 412 · cited 1×
“They also calculate and display stroke volume variation (SVV), which has been assumed to reflect the respiratory variation of stroke volume in patients receiving mechanical ventilation (31).”
BackgroundUsing heart-lung interactions to assess fluid responsiveness during mechanical ventilation.
Michard, F., & Teboul, J. (2000) · Critical Care · doi:10.1186/cc710 · Cited by 409
Self-citationPerel, A., Pizov, R., & Cotev, S. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00009 · Cited by 403
Cannesson, M. P., Desebbe, O., Rosamel, P., Delannoy, B., Robin, J., Bastien, O. H., & Lehot, J.-J. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen133 · Cited by 377 · cited 1×
“The respiratory changes in the amplitude of the plethysmographic signal predict fluid responsiveness with acceptable accuracy (34, 35), except in patients receiving norepinephrine (36, 37).”
BackgroundMICHARD, F., CHEMLA, D., RICHARD, C., WYSOCKI, M., PINSKY, M. R., LECARPENTIER, Y., & TEBOUL, J.-L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9805077 · Cited by 371 · cited 6×
“We postulated that PPV reflects the respiratory changes in stroke volume and thus, should serve to assess fluid responsiveness (23, 24), assuming that the arterial compliance does not change over the respiratory cycle, a hypothesis confirmed experimentally (25).”
BackgroundMethodInfluentialSelf-citationTrends in the Use of the Pulmonary Artery Catheter in the United States, 1993-2004
Wiener, R. S., & Welch, H. G. (2007) · JAMA · doi:10.1001/jama.298.4.423 · Cited by 343 · cited 1×
“Since that time, the use of the pulmonary artery catheter has declined dramatically (1).”
BackgroundComparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308 · cited 3×
“PPV as well as echocardiographic fluid responsiveness indices did not reliably predict fluid responsiveness (62).”
BackgroundCyclic changes in right ventricular output impedance during mechanical ventilation
Vieillard-Baron, A., Loubieres, Y., Schmitt, J.-M., Page, B., Dubourg, O., & Jardin, F. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1644 · Cited by 303 · cited 2×
“As a result, the RV stroke volume is minimal at the end of insufflation (15, 18).”
BackgroundPassive leg raising for predicting fluid responsiveness: importance of the postural change
Jabot, J., Teboul, J.-L., Richard, C., & Monnet, X. (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1293-3 · Cited by 289 · cited 1×
“Since passive leg raising was shown to be hemodynamically equivalent to 312 [250-350] mL fluid administration (63),”
BackgroundSelf-citationTranspulmonary thermodilution: advantages and limits
Monnet, X., & Teboul, J.-L. (2017) · Critical Care · doi:10.1186/s13054-017-1739-5 · Cited by 285 · cited 1×
“In cases where the risks of lung edema are not negligible, additional variables, such as extravascular lung water (74) or the presence of B-lines on lung ultrasound examination (75), are useful in making the appropriate decision.”
BackgroundSelf-citationReuter, D. A., Kirchner, A., Felbinger, T. W., Weis, F. C., Kilger, E., Lamm, P., & Goetz, A. E. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000059442.37548.e1 · Cited by 281 · cited 1×
“In some studies, including patients with left ventricular dysfunction and in sinus rhythm, PPV (or SVV) was reported to predict fluid responsiveness with an acceptable accuracy (41, 58).”
BackgroundYang, X., & Du, B. (2014) · Critical Care · doi:10.1186/s13054-014-0650-6 · Cited by 258 · cited 1×
“responsiveness with great accuracy in mechanically ventilated patients (12, 20, 21).”
BackgroundBenes, J., Giglio, M., Brienza, N., & Michard, F. (2014) · Critical Care · doi:10.1186/s13054-014-0584-z · Cited by 257 · cited 3×
“Conditions for its optimum utilization are usually met in the OR, where fluid management strategies based on PPV (or SVV) monitoring have shown to reduce postoperative morbidity (70).”
BackgroundMethodInfluentialSelf-citationMonnet, X., Bleibtreu, A., Ferré, A., Dres, M., Gharbi, R., Richard, C., & Teboul, J.-L. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31822f08d7 · Cited by 246 · cited 3×
“Interestingly, among fluid responders, there was a subset of patients ventilated with a VT <8 mL/kg, a Crs >30 mL/cmH2O and a high PPV and another subset with a VT >8 mL/kg, a Crs ≤30 mL/cmH2O, and a low PPV (5% on average), suggesting that the decreased Crs might play a more important role than the low VT in the poor…”
BackgroundInfluentialSelf-citationPerioperative cardiovascular monitoring of high-risk patients: a consensus of 12
Vincent, J.-L., Pelosi, P., Pearse, R., Payen, D., Perel, A., Hoeft, A., Romagnoli, S., Ranieri, V. M., Ichai, C., Forget, P., et al. (2015) · Critical Care · doi:10.1186/s13054-015-0932-7 · Cited by 243 · cited 1×
“Tailoring fluid administration to individual needs is recommended (68).”
BackgroundMyatra, S. N., Prabu, N. R., Divatia, J. V., Monnet, X., Kulkarni, A. P., & Teboul, J.-L. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002183 · Cited by 236 · cited 1×
“As mentioned above, this is a good indication of performing a VT challenge consisting of transiently increasing VT (from 6 to 8 mL/kg) and measuring the absolute changes in PPV (45, 46).”
BackgroundSelf-citationFurukawa, T., Ogura, T., Katayama, Y., & Hiraoka, M. (1998) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1998.274.2.c500 · Cited by 214
Influence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated Patients
De Backer, D., Taccone, F. S., Holsten, R., Ibrahimi, F., & Vincent, J.-L. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819db2a1 · Cited by 207
Monge García, M. I., Gil Cano, A., & Gracia Romero, M. (2011) · Critical Care · doi:10.1186/cc9420 · Cited by 192
Clinical Usefulness of Respiratory Variations in Arterial Pressure
Magder, S. A. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200211-1360cc · Cited by 157 · cited 1×
“intubated and ventilated with persistent respiratory efforts, 2) patients with non-invasive ventilation, and 3) patients with no mechanical ventilation, whether the expiration is active (73) or not.”
BackgroundApplicability of pulse pressure variation: how many shades of grey?
Michard, F., Chemla, D., & Teboul, J. (2015) · Critical Care · doi:10.1186/s13054-015-0869-x · Cited by 152 · cited 1×
“Further studies in different clinical settings confirmed the utility of PPV as a reliable predictor of fluid responsiveness in patients ventilated with a tidal volume (VT) of at least 8 mL/kg (19, 20) provided that they have no spontaneous breathing activity and/or cardiac arrhythmias (28).”
BackgroundSelf-citationSandroni, C., Cavallaro, F., Marano, C., Falcone, C., Santis, P. D., & Antonelli, M. M. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2621-1 · Cited by 134 · cited 1×
“The respiratory changes in the amplitude of the plethysmographic signal predict fluid responsiveness with acceptable accuracy (34, 35), except in patients receiving norepinephrine (36, 37).”
BackgroundMonnet, X., Dres, M., Ferré, A., Teuff, G. L., Jozwiak, M., Bleibtreu, A., Deley, M. L., Chemla, D., Richard, C., & Teboul, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes182 · Cited by 132 · cited 2×
“The PPV measured using a finger blood pressure device (volume clamp method) was as reliable as the invasively obtained PPV to predict fluid responsiveness in the operating room (OR) (32) as well as in the ICU (33) settings.”
BackgroundMethodSelf-citationEstimating cardiac filling pressure in mechanically ventilated patients with hyperinflation
Teboul, J., Pinsky, M. R., Mercat, A., Anguel, N., Bernardin, G., Achard, J., Boulain, T., & Richard, C. (2000) · Critical Care Medicine · doi:10.1097/00003246-200011000-00014 · Cited by 131 · cited 1×
“Although the chest wall compliance is generally reduced, the resultant effect is a decrease in that airway pressure transmission as illustrated by the correlation between Crs and the airway pressure transmission found in a previous study (48).”
BackgroundSelf-citationOnline Monitoring of Pulse Pressure Variation to Guide Fluid Therapy After Cardiac Surgery
Júnior, J. O. C. A., Galas, F. R. B. G., Hajjar, L. A., dos Santos, L. O., Carvalho, T. F. G. D. L., & Michard, F. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000287664.03547.c6 · Cited by 127 · cited 1×
“Today, most hemodynamic monitors allow automatic calculation of PPV with continuous display of its value in real time (29).”
BackgroundSelf-citationAlternatives to the Swan–Ganz catheter
Backer, D. D., Bakker, J., Cecconi, M., Hajjar, L. A., Liu, D. W., Lobo, S., Monnet, X., Morelli, A., Myatra, S. N., Perel, A., et al. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5187-8 · Cited by 121 · cited 1×
“These findings eventually contributed 1) to move away from the concept of maximization of oxygen delivery to the concept of individualization of the therapeutic strategy, and 2) to developing novel and less invasive alternatives to pulmonary artery catheterization (7).”
BackgroundSelf-citationMonnet, X., Guérin, L., Jozwiak, M., Bataille, A., Fournier, J., Richard, C., & Teboul, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes373 · Cited by 105 · cited 1×
“The respiratory changes in the amplitude of the plethysmographic signal predict fluid responsiveness with acceptable accuracy (34, 35), except in patients receiving norepinephrine (36, 37).”
BackgroundSelf-citationYonis, H., Bitker, L., Aublanc, M., Périnel, S., Riad, Z., Lissonde, F., Louf-Durier, A., Debord, S., Gobert, F., Tapponnier, R., et al. (2017) · Critical Care · doi:10.1186/s13054-017-1881-0 · Cited by 101
Jugular vein distensibility predicts fluid responsiveness in septic patients
Guarracino, F., Ferro, B., Forfori, F., Bertini, P., Magliacano, L., & Pinsky, M. R. (2014) · Critical Care · doi:10.1186/s13054-014-0647-1 · Cited by 100 · cited 1×
“The respiratory changes in ultrasound variables such as the velocity time-integral (VTI) of the LV outflow track (echocardiography) (38), the aortic blood flow (esophageal Doppler) (39), the diameter of the inferior (40) or superior vena cava (41) and the diameter of the internal jugular vein (42) have been shown to b…”
BackgroundDigital innovations and emerging technologies for enhanced recovery programmes
Michard, F., Gan, T. J., & Kehlet, H. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex140 · Cited by 94
Self-citationCecconi, M., García, M. I. M., Romero, M. Á. G., Mellinghoff, J., Caliandro, F., Grounds, R. M., & Rhodes, A. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000442 · Cited by 76 · cited 1×
“Two clinical studies (76, 77) suggested that a low PPV/SVV ratio predicts the absence of blood pressure”
BackgroundPulse pressure variation: beyond the fluid management of patients with shock
Michard, F., Lopes, M. R., & Júnior, J. O. C. A. (2007) · Critical Care · doi:10.1186/cc5905 · Cited by 75 · cited 1×
“maintaining PPV within the range 10-15%, should protect from the consequences of both hypovolemia and fluid overload (69).”
BackgroundSelf-citationUse of ‘tidal volume challenge’ to improve the reliability of pulse pressure variation
Myatra, S. N., Monnet, X., & Teboul, J. (2017) · Critical Care · doi:10.1186/s13054-017-1637-x · Cited by 74 · cited 2×
“transient (less than one minute) increase in VT (45).”
BackgroundSelf-citationVos, J. J., Kalmar, A. F., Struys, M. M. R. F., Wietasch, G. J. K. G., Hendriks, H. G. D., & Scheeren, T. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aes508 · Cited by 71 · cited 1×
“However, other studies have failed to replicate these results (78, 79).”
ResultBiais, M., Cottenceau, V., Petit, L., Masson, F., Cochard, J.-F., & Sztark, F. (2011) · Critical Care · doi:10.1186/cc10310 · Cited by 69 · cited 1×
“The respiratory changes in the amplitude of the plethysmographic signal predict fluid responsiveness with acceptable accuracy (34, 35), except in patients receiving norepinephrine (36, 37).”
BackgroundLiu, Y., Wei, L., Li, G., Yu, X., Li, G., & Li, Y. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001371 · Cited by 61
Heart–lung interactions and pulmonary buffering: Lessons from a computational modeling study
Magder, S. A., & Guerard, B. (2012) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2012.05.011 · Cited by 57 · cited 3×
“Further studies in different clinical settings confirmed the utility of PPV as a reliable predictor of fluid responsiveness in patients ventilated with a tidal volume (VT) of at least 8 mL/kg (19, 20) provided that they have no spontaneous breathing activity and/or cardiac arrhythmias (28).”
BackgroundMethodEffects of arterial load variations on dynamic arterial elastance: an experimental study
García, M. I. M., González, P. G., Romero, M. Á. G., Cano, A., Rhodes, A., Grounds, R. M., & Cecconi, M. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex070 · Cited by 56
Biais, M., Stecken, L., Ottolenghi, L., Roullet, S., Quinart, A., Masson, F., & Sztark, F. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182240054 · Cited by 48 · cited 1×
“The PPV measured using a finger blood pressure device (volume clamp method) was as reliable as the invasively obtained PPV to predict fluid responsiveness in the operating room (OR) (32) as well as in the ICU (33) settings.”
MethodPréau, S., Dewavrin, F., Demaeght, V., Chiche, A., Voisin, B., Minacori, F., Poissy, J., Geronimi, C. B., Blazejewski, C., Onimus, T., et al. (2015) · Anaesthesia Critical Care & Pain Medicine · doi:10.1016/j.accpm.2015.08.003 · Cited by 42 · cited 1×
“As an example, in a prospective study that included ICU patients, who actually received fluid boluses, the incidence of cases where PPV could be used without limitation was 17% (65).”
MethodMin, J. J., Gil, N., Lee, J., Ryu, D. K., Kim, C., & Lee, S. M. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex074 · Cited by 34 · cited 1×
“Challenging PPV following a transient increase in VT from 8 to 12 mL/kg has been proposed to overcome this limitation (72).”
BackgroundPredicting Fluid Responsiveness in Acute Liver Failure: A Prospective Study
Audimoolam, V. K., McPhail, M. J. W., Willars, C., Bernal, W. E., Wendon, J. A., Cecconi, M., & Auzinger, G. M. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001585 · Cited by 28 · cited 1×
“In a series of ventilated patients with acute liver failure, the authors concluded that PPV predicted fluid responsiveness, whereas the respiratory changes in VTI were not predictive (60).”
BackgroundThe Influence of Positive-Pressure Ventilation on Cardiovascular Function in the Critically Ill
Pinsky, M. R. (1985) · Critical Care Clinics · doi:10.1016/s0749-0704(18)30651-1 · Cited by 13 · cited 2×
“ventilation induces cyclic changes in loading conditions of both ventricles (14-17) (Figure 2).”
BackgroundMethodCan Passive Leg Raising Be Considered the Gold Standard in Predicting Fluid Responsiveness?
Vistisen, S. T., Enevoldsen, J., & Scheeren, T. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201701-0060le · Cited by 6 · cited 1×
“This may have resulted in higher rates of false positive, and to a lesser extent in higher rates of false negative cases of PPV (64) compared to studies that assessed fluid responsiveness using a real fluid administration.”
Result
Cited by
Prediction of fluid responsiveness. What’s new?
Monnet, X., Shi, R., & Teboul, J.-L. (2022) · Annals of Intensive Care · doi:10.1186/s13613-022-01022-8 · Cited by 249
“This was confirmed in a meta-analysis of 11 studies (1015 patients) performed in surgical ICU patients and in which a strategy based on SVV reduced the ICU and hospital lengths of stay and tended to decrease mortality [101].”
BackgroundInfluentialSelf-citationHow can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“The essential limitation of PPV is that it cannot be used in many clinical circumstances that create false positives (spontaneous ventilation, cardiac arrhythmia, right ventricular failure) and false negatives (low tidal volume, low lung compliance, very high respiratory rate) [54].”
BackgroundSelf-citationFluid Therapy for Critically Ill Adults With Sepsis: A Review
Zampieri, F. G., Bagshaw, S. M., & Semler, M. W. (2023) · JAMA · doi:10.1001/jama.2023.7560 · Cited by 184
Metadata
- Authors
- Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-01-01
- Volume
- 199
- Issue
- 1
- Pages
- 22-31
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2888605280
- Cited by
- 200
- References
- 69
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.