A Microfluidic Device with 3-D Hydrogel Villi Scaffold to Simulate Intestinal Absorption
The DOI matches its Crossref record.
Abstract
The absorption of drugs via oral route is a subject of a great interest in drug development process. The current in vitro method for measuring the kinetics of drug absorption relies on 2-D monolayer culture of Caco-2 cells on a porous membrane, but physiologically unrealistic environment provided by this method often results in inaccurate drug absorption kinetics. Here we report a novel microfluidic system which better mimics the physiological environment of the human small intestine. Three dimensional geometries of villi of the small intestine were reproduced via novel hydrogel microfabrication technique, and the fluid flow in the apical and basolateral sides of intestinal tract was reproduced with a two-layer microfluidic device. A wide range of flow rates was achieved by using gravity-induced flow, potentially facilitating easier high-throughput implementation. The kinetics of diffusion process through the 3-D villi scaffold in the microfluidic device was measured and mathematically modeled. When combined with intestinal cell culture model, this novel 3-D microfluidic system can serve as an in vitro platform that better mimics the in vivo environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, Y., Gunasekara, D. B., Reed, M. I., DiSalvo, M., Bultman, S. J., Sims, C. E., Magness, S. T., & Allbritton, N. L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.005 · Cited by 373
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“…al., 2012), permeability (Lee et al., 2014), pattern diffusive gradients (Baker et al., 2013), micro-vascular environments (Hasenberg et al., 2015; Kim et al., 2013b; Park et al., 2014; Tourovskaia et al., 2014; Wang et al., 2014a) and vascular response to vessel geometries (Ye et al., 2014) have…”
Microfluidic gut-on-a-chip with three-dimensional villi structure
Shim, K.-Y., Lee, D., Han, J., Nguyen, N.-T., Park, S., & Sung, J. H. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0179-y · Cited by 229
Self-citationMicrofluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Metadata
- Authors
- Kim, S. H., Lee, J. W., Choi, I., Kim, Y.-C., Lee, J. B., & Sung, J. H.
- Venue
- Journal of Nanoscience and Nanotechnology
- Publisher
- American Scientific Publishers
- Published
- 2013-11-01
- Volume
- 13
- Issue
- 11
- Pages
- 7220-7228
- ISSN
- 1533-4880 (ISSN-L)
- 1533-4899
- OpenAlex
- W2063515263
- Cited by
- 42
- References
- 0
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Microfluidic Device with 3-D Hydrogel Villi Scaffold to Simulate Intestinal Absorption. https://app.cochat.ai/papers/10.1166/jnn.2013.8088
- The paper
- Kim, S. H., Lee, J. W., Choi, I., Kim, Y.-C., Lee, J. B., & Sung, J. H. (2013). A Microfluidic Device with 3-D Hydrogel Villi Scaffold to Simulate Intestinal Absorption. Journal of Nanoscience and Nanotechnology. https://doi.org/10.1166/jnn.2013.8088
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.