Visual performance in emmetropia and low myopia after correction of high-order aberrations
Open accessThe DOI matches its Crossref record.
Abstract
Myopic observers may not benefit to the same extent as emmetropes from adaptive optics (AO) correction in a visual acuity (VA) task. To investigate this, we measured AO-corrected VA in 10 low myopes and 9 emmetropes. Subjects were grouped by refractive error. Mean spherical equivalent refractive error was -2.73 D (SEM = 0.35) for the myopes and 0.04 D (SEM = 0.1) for the emmetropes. All subjects had best corrected VA of 20/20 or better. The AO scanning laser ophthalmoscope was used to project ultrasharp stimuli onto the retina of each observer. High-contrast photopic acuity was measured using a tumbling E test with and without AO correction. AO-corrected minimum angle of resolution was 0.61' (SEM = 0.02') for the myopes and 0.49' (SEM = 0.03') for the emmetropes. The difference between groups is significant (p = .0017). This effect is even greater (p = .00013) when accounting for spectacle magnification and axial length, with myopes and emmetropes able to resolve critical features on the retina with a mean size of 2.87 mum (SEM = 0.07) and 2.25 mum (SEM = 0.1), respectively. Emmetropes and low myopes will both benefit from AO correction in a VA task but not to the same extent. Optical aberrations do not limit VA in low myopia after AO correction. There is no difference in the high-order aberrations of emmetropes and low myopes. Retinal and/or cortical factors limit VA in low myopes after AO correction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The relationship between visual resolution and cone spacing in the human fovea
Rossi, E. A., & Roorda, A. (2010) · Nature Neuroscience · doi:10.1038/nn.2465 · Cited by 255
Self-citationIndividual Variations in Human Cone Photoreceptor Packing Density: Variations with Refractive Error
Chui, T. Y. P., Song, H., & Burns, S. A. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2135 · Cited by 191
Imaging single cells in the living retina
Williams, D. R. (2011) · Vision Research · doi:10.1016/j.visres.2011.05.002 · Cited by 175
Relationship between the Foveal Avascular Zone and Foveal Pit Morphology
Dubis, A. M., Hansen, B. R., Cooper, R. F., Beringer, J., Dubra, A., & Carroll, J. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8488 · Cited by 173
“Evidence against this comes from the Downloaded from iovs.arvojournals.org on 03/09/2019 finding that the normal range of foveal pit morphology overlaps with that seen in albinism (Carroll J, et al. IOVS 2011;52: ARVO E-Abstract 2175) and that, in patients with albinism, pit depth is not a reliable predictor of visual…”
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
“Consequently, the diameter of a single spot percept can be estimated in the range of the grid spacing, extending 280 m on the retina or 60 arc min of visual angle.(46) This description matches that by S10 (second-generation implant, larger electrodes) who was asked to estimate the size of the dark area between two dot…”
BackgroundBinocular visual performance and summation after correcting higher order aberrations
Sabesan, R., Zheleznyak, L., & Yoon, G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.003176 · Cited by 59
Carroll, J., Rossi, E. A., Porter, J., Neitz, J., Roorda, A., Williams, D. R., & Neitz, M. (2010) · Vision Research · doi:10.1016/j.visres.2010.07.009 · Cited by 49
Self-citation
Metadata
- Authors
- Rossi, E. A., Weiser, P., Tarrant, J., & Roorda, A.
- Venue
- Journal of Vision
- Published
- 2007-06-27
- Volume
- 7
- Issue
- 8
- Pages
- 14
- ISSN
- 1534-7362 (ISSN-L)
- OpenAlex
- W2004348419
- Cited by
- 96
- References
- 0
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.