Imaging single cells in the living retina
Open accessThe DOI matches its Crossref record; 130 of the 130 references it cites were found in a registry or an index.
Abstract
A quarter century ago, we were limited to a macroscopic view of the retina inside the living eye. Since then, new imaging technologies, including confocal scanning laser ophthalmoscopy, optical coherence tomography, and adaptive optics fundus imaging, transformed the eye into a microscope in which individual cells can now be resolved noninvasively. These technologies have enabled a wide range of studies of the retina that were previously impossible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772 · cited 2×
“Remarkably, the field of microscopy has already seen the diffraction barrier fall, not once but many times, thanks to an array of new techniques including structured illumination (Gustafsson, 1999), stimulated emission depletion (Hell & Wichmann, 1994), and photoactivation localization microscopy (Betzig et al., 2006).”
BackgroundHell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065 · cited 1×
“…of microscopy has already seen the diffraction barrier fall, not once but many times, thanks to an array of new techniques including structured illumination (Gustafsson, 1999), stimulated emission depletion (Hell & Wichmann, 1994), and photoactivation localization microscopy (Betzig et al., 2006).”
BackgroundSensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Memoir on inventing the confocal scanning microscope
Minsky, M. (1988) · Scanning · doi:10.1002/sca.4950100403 · Cited by 1,556
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454 · cited 1×
“…2010; Elliott et al., 2009; Guo & Atchison, 2010; Gupta, Guo, Atchison, & Zele, 2010; Li, Xiong, Li, et al., 2009; Li, Xiong, Wang, et al., 2009; Liang et al., 1997; Lundstrom et al., 2007; Marcos, Sawides, Gambra, & Dorronsoro, 2008; Perez, Manzanera, & Artal, 2009; Rocha, Vabre, Chateau, &…”
Self-citationMeasurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Liang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195 · cited 2×
“Liang, working as a graduate student in Josef Bille’s laboratory at the University of Heidelberg demonstrated that it was possible to adapt for use in the eye the Shack–Hartmann wavefront sensor that is widely used in astronomical adaptive optics (Liang et al., 1994).”
BackgroundHecht, S., Shlaer, S., & Pirenne, M. H. (1942) · Journal of General Physiology · doi:10.1085/jgp.25.6.819 · Cited by 1,122 · cited 1×
“Perhaps the best example is the brilliant paper of Hecht, Schlaer, and Pirenne (1942) in which they concluded that 10 photons are required to detect a flash at absolute threshold.”
BackgroundOptical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033 · cited 2×
“E-mail address: david@cvs.rochester.edu A quarter century ago, we were limited to a macroscopic view of the retina inside the living eye.”
Background
Cited by
Roles of HIFs and VEGF in angiogenesis in the retina and brain
Rattner, A., Williams, J., & Nathans, J. (2019) · Journal of Clinical Investigation · doi:10.1172/jci126655 · Cited by 219
Imaging and quantifying ganglion cells and other transparent neurons in the living human retina
Liu, Z., Kurokawa, K., Zhang, F., Lee, J. J., & Miller, D. T. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1711734114 · Cited by 217
Functional Circuitry of the Retina
Demb, J. B., & Singer, J. H. (2015) · Annual Review of Vision Science · doi:10.1146/annurev-vision-082114-035334 · Cited by 216
“%) show peak sensitivity to short wavelengths (S, ~430 nm) (Williams 2011).”
BackgroundJACOBS, G. H. (2013) · Visual Neuroscience · doi:10.1017/s0952523812000429 · Cited by 159
“which allows high spatial resolution views of the photoreceptor mosaic (Williams, 2011).”
Background
Metadata
- Authors
- Williams, D. R.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 51
- Issue
- 13
- Pages
- 1379-1396
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W1983389864
- Cited by
- 175
- References
- 130
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging single cells in the living retina. https://app.cochat.ai/papers/10.1016/j.visres.2011.05.002
- The paper
- Williams, D. R. (2011). Imaging single cells in the living retina. Vision Research. https://doi.org/10.1016/j.visres.2011.05.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.