How Sensitive to Clinical Change are ETDRS logMAR Visual Acuity Measurements?
Abstract
PURPOSE: To determine the sensitivity to change and specificity achieved when published test-retest variability (TRV) data are used to determine whether measured changes in ETDRS logarithm of the minimum angle of resolution (logMAR) visual acuity reflect true clinical change or are attributable to measurement error alone. METHODS: Various degrees of change in visual acuity were simulated in a group of normal subjects by adjusting test difficulty through manipulation of viewing distance. Sensitivity to simulated change and specificity were determined with change criteria derived from published Bland-Altman 95% ranges for TRV. RESULTS: The relationship between viewing distance and measured acuity was as predicted theoretically. Simulated acuity change of 0.2 logMAR (two lines of letters) or greater can be reliably distinguished from no change (both sensitivity and specificity >95%) with the ETDRS chart, but a change of 0.1 logMAR or less cannot. CONCLUSIONS: The use of 95% ranges for TRV to establish the smallest measured visual acuity change that can be reliably detected ensures a high specificity but does not take account of sensitivity. Use of change criteria derived from published 95% ranges results in a sensitivity of approximately 50% (assuming identical levels of TRV). Sensitivity may be improved by using a change criterion that is smaller than the minimum change sought, providing the change criterion is still at least as large as the 95% range for TRV, so that specificity is maintained. Reducing TRV allows smaller changes in acuity to be reliably detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Turiel, E. (2007) · Handbook of Child Psychology · doi:10.1002/9780470147658.chpsy0313 · Cited by 2,143
New Visual Acuity Charts for Clinical Research
Ferris, F. L., Kassoff, A., Bresnick, G. H., & Bailey, I. (1982) · American Journal of Ophthalmology · doi:10.1016/0002-9394(82)90197-0 · Cited by 2,142
New Design Principles for Visual Acuity Letter Charts
Bailey, I. L., & Lovie, J. E. (1976) · American journal of optometry and physiological optic · doi:10.1002/j.2330-9512.1976.tb02218.x · Cited by 1,407
Clinical grading and the effects of scaling.
Bailey, I. L., Bullimore, M. A., Raasch, T. W., & Taylor, H. R. (1991) · PubMed · Cited by 505
Validity and reliability of visual acuity measurements
Lovie‐Kitchin, J. E. (1988) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1988.tb01170.x · Cited by 249
On the statistical reliability of letter-chart visual acuity measurements.
Arditi, A. R., & Cagenello, R. (1993) · PubMed · Cited by 239
The development of a "reduced logMAR" visual acuity chart for use in routine clinical practice
Rosser, D. A. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.432 · Cited by 201
Self-citationThe use of accurate visual acuity measurements in clinical anti‐cataract formulation trials
Elliott, D. B., & Sheridan, M. (1988) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1988.tb01176.x · Cited by 146
Me, V. B., & Wall, M. (1997) · Eye · doi:10.1038/eye.1997.87 · Cited by 131
Vistech VCTS 6500 Charts???Within- and Between-Session Reliability
Reeves, B. C., WOOD, J. M., & HILL, A. R. (1991) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1991.tb02802.x · Cited by 99
Reliability of high‐ and low‐contrast letter charts
Reeves, B. C., Wood, J. M., & Hill, A. R. (1993) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1993.tb00421.x · Cited by 73
Cited by
Kashani, A. H., Lebkowski, J. S., Rahhal, F. M., Avery, R. L., Salehi-Had, H., Dang, W., Lin, C.-M., Mitra, D., Zhu, D., Thomas, B. B., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aao4097 · Cited by 373
Longitudinal study of vision and retinal nerve fiber layer thickness in multiple sclerosis
Talman, L. S., Bisker, E. R., Sackel, D. J., Long, D. A., Galetta, K. M., Ratchford, J. N., Lile, D. J., Farrell, S. K., Loguidice, M. J., Remington, G., et al. (2010) · Annals of Neurology · doi:10.1002/ana.22005 · Cited by 366
Bastawrous, A., Rono, H. K., Livingstone, I. A. T., Weiss, H. A., Jordan, S., Kuper, H., & Burton, M. J. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.1468 · Cited by 339
Ganglion Cell Loss in Relation to Visual Disability in Multiple Sclerosis
Walter, S. D., Ishikawa, H., Galetta, K. M., Sakai, R. E., Feller, D. J., Henderson, S. B., Wilson, J. A., Maguire, M. G., Galetta, S. L., Frohman, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.11.032 · Cited by 294
Metadata
- Authors
- Rosser, D. A., Cousens, S. N., Murdoch, I. E., Fitzke, F. W., & Laidlaw, D. A. H.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2003-08-01
- Volume
- 44
- Issue
- 8
- Pages
- 3278
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1981223543
- Cited by
- 264
- References
- 12
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.