The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The Reflectance of Single Cones in the Living Human Eye
Abstract
PURPOSE: Individual cones were imaged in the living human eye with the Rochester adaptive optics ophthalmoscope. In all eyes, there were large differences in the reflectance of different cones, even when all the photopigment was bleached. To help understand what produces this spatial variation, the investigators explored whether it is a static or a dynamic property of the cone mosaic. METHODS: Fully bleached cone images were acquired in three eyes with an adaptive optics system. Images were collected over a 10-minute period approximately every hour for 24 hours. The temporal variation in cone directionality was measured in one eye. Finally, the experimental data on the temporal variation of absorption were compared with findings in various models of reflectance. RESULTS: Cone reflectance changes over time appear to be independent from cone to cone. These temporal changes are present in all three cone classes. The spatiotemporal variation in cone reflectance is not caused by the spatiotemporal variation in the optical axes of cones. This, along with the modeling results, suggest that changes in the reflectance affect the light that passes through photopigment in the receptors rather than the stray light, and that the changes are related to the outer segment-retinal pigment epithelium (RPE) interface. CONCLUSIONS: The reflectance of individual cones is a dynamic property of the mosaic. Changes can be observed over periods of minutes as well as many hours. The cause of the variation is not known but may be related to the process of disc shedding in receptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The renewal of photoreceptor cell outer segments
Young, R. W. (1967) · The Journal of Cell Biology · doi:10.1083/jcb.33.1.61 · Cited by 1,184
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Cited by
Organization of the human trichromatic cone mosaic
Hofer, H., Carroll, J., Neitz, J., Neitz, M., & Williams, D. R. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2414-05.2005 · Cited by 364
Self-citationVariation of Cone Photoreceptor Packing Density with Retinal Eccentricity and Age
Song, H., Chui, T. Y. P., Zhong, Z., Elsner, A. E., & Burns, S. A. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7199 · Cited by 267
Adaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
High-Resolution Imaging with Adaptive Optics in Patients with Inherited Retinal Degeneration
Duncan, J. L., Zhang, Y., Gandhi, J., Nakanishi, C., Othman, M., Branham, K. E. H., Swaroop, A., & Roorda, A. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-1422 · Cited by 262
Functional photoreceptor loss revealed with adaptive optics: An alternate cause of color blindness
Carroll, J., Neitz, M., Hofer, H., Neitz, J., & Williams, D. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401440101 · Cited by 191
Self-citationAdaptive optics retinal imaging reveals S-cone dystrophy in tritan color vision deficiency
Baraas, R. C., Carroll, J., Gunther, K. L., Chung, M., Williams, D. R., Foster, D. H., & Neitz, M. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001438 · Cited by 100
Self-citationCarroll, J., Rossi, E. A., Porter, J., Neitz, J., Roorda, A., Williams, D. R., & Neitz, M. (2010) · Vision Research · doi:10.1016/j.visres.2010.07.009 · Cited by 49
Self-citation
Metadata
- Authors
- Pallikaris, A., Williams, D. R., & Hofer, H.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2003-10-01
- Volume
- 44
- Issue
- 10
- Pages
- 4580
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1980473319
- Cited by
- 176
- References
- 2
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.