Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 404

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Axial Growth and Changes in Lenticular and Corneal Power during Emmetropization in Infants

Mutti, Donald O., Mitchell, G. Lynn, Jones, Lisa A., Friedman, Nina E., Frane, Sara L., Lin, Wendy K., Moeschberger, Melvin L., Zadnik, Karla·2005·Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To evaluate the contribution made by the ocular components to the emmetropization of spherical equivalent refractive error in human infants between 3 and 9 months of age. METHODS: Keratophakometry in two meridians was performed on 222 normal-birthweight infant subjects at 3 and 9 months of age. The spherical equivalent refractive error was measured by cycloplegic retinoscopy (cyclopentolate 1%). Anterior chamber depth, lens thickness, and vitreous chamber depth were measured by A-scan ultrasonography over the closed eyelid. RESULTS: Both the mean and SD for spherical equivalent refractive error decreased between 3 and 9 months of age (+2.16 +/- 1.30 D at 3 months; +1.36 +/- 1.06 D at 9 months; P < 0.0001, for the change in both mean and SD). Average ocular component change was characterized by increases in axial length, thinning, and flattening of the crystalline lens, increases in lens equivalent refractive index, and decreases in lens and corneal power. Initial refractive error was associated in a nonlinear manner with the change in refractive error (R(2) = 0.41; P < 0.0001) and with axial growth (R(2) = 0.082; P = 0.0005). Reduction in hyperopia correlated significantly with increases in axial length (R(2) = 0.16; P < 0.0001), but not with changes in corneal and lenticular power. Decreases in lenticular and corneal power were associated with axial elongation (R(2) = 0.40, R(2) = 0.12, respectively; both P < 0.0001). CONCLUSIONS: Modulation in the amount of axial growth in relation to initial refractive error appeared to be the most influential factor in emmetropization of spherical equivalent refractive error. The associations between initial refractive error, subsequent axial growth, and change in refractive error were consistent with a visual basis for emmetropization. The cornea and crystalline lens lost substantial amounts of dioptric power in this phase of growth, but neither appeared to play a significant role in emmetropization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.04-1040

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 404

Metadata

Authors
Mutti, D. O., Mitchell, G. L., Jones, L. A., Friedman, N. E., Frane, S. L., Lin, W. K., Moeschberger, M. L., & Zadnik, K.
Venue
Investigative Opthalmology & Visual Science
Published
2005-09-01
Volume
46
Issue
9
Pages
3074
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2078231330
Cited by
404
References
18
FWCI
5.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Axial Growth and Changes in Lenticular and Corneal Power during Emmetropization in Infants. https://app.cochat.ai/papers/10.1167/iovs.04-1040
The paper
Mutti, D. O., Mitchell, G. L., Jones, L. A., Friedman, N. E., Frane, S. L., Lin, W. K., Moeschberger, M. L., & Zadnik, K. (2005). Axial Growth and Changes in Lenticular and Corneal Power during Emmetropization in Infants. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.04-1040

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.