The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Near-Infrared Autofluorescence Imaging of the Fundus: Visualization of Ocular Melanin
Abstract
PURPOSE: To evaluate the origin of the near-infrared autofluorescence (AF) of the fundus detected by scanning laser ophthalmoscopy and compare the distribution of this AF with that of lipofuscin. METHODS: AF [787] fundus images (excitation [Exc.] 787 nm; emission [Emi.] >800 nm) were recorded with a confocal scanning laser ophthalmoscope, in 85 normal subjects (ages: 11-77 years) and in 25 patients with AMD and other retinal diseases. Standard AF [488] images (Exc. 488 nm; Emi. >500 nm) were recorded in a subset of the population. RESULTS: The fovea exhibits higher AF[787] than the perifovea in an area approximately 8 degrees in diameter, roughly equivalent to the area of higher RPE melanin seen in AF[488] and color images. The ratio of foveal to perifoveal AF[787] decreases with age (P < 0.0001) and is higher in subjects with light irides (P = 0.04). Higher AF[787] emanates from hyperpigmentation, from the choroidal pigment (nevi, outer layers) and from the pigment epithelium and stroma of the iris. Low AF[787] is observed in geographic atrophy particularly in subjects with light irides. CONCLUSIONS: AF[787] originates from the RPE and to a varying degree from the choroid. Oxidized melanin, or compounds closely associated with melanin, contributes substantially to this AF, but other fluorophores cannot be excluded at this stage. Confocal AF[787] imaging may provide a new modality to visualize pathologic features of the RPE and the choroid, and, together with AF[488] imaging, offers a new tool to study biological changes associated with aging of the RPE and pathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 2,790
Delori, F. C., Dorey, C. K., Staurenghi, G., Arend, O., Goger, D. G., & Weiter, J. J. (1995) · PubMed · Cited by 948
Self-citationIn Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications
Wagnieres, G. A., Star, W. M., & Wilson, B. C. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02521.x · Cited by 942
Evolution of geographic atrophy of the retinal pigment epithelium
Sarks, J. P., Sarks, S. H., & Killingsworth, M. C. (1988) · Eye · doi:10.1038/eye.1988.106 · Cited by 804
Worthen, D. M. (1972) · Archives of Ophthalmology · doi:10.1001/archopht.1972.01000030236034 · Cited by 798
Confocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
Self-citationOxidative Damage and Age Related Macular Degeneration
Renganathan, K. (2008) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 566
Retinal pigment epithelial lipofuscin and melanin and choroidal melanin in human eyes.
Weiter, J. J., Delori, F. C., Wing, G. L., & Fitch, K. A. (1986) · PubMed · Cited by 565
Self-citationAging human RPE: morphometric analysis of macular, equatorial, and peripheral cells.
Feeney-Burns, L., Hilderbrand, E. S., & Eldridge, S. (1984) · PubMed · Cited by 561
Distribution of fundus autofluorescence with a scanning laser ophthalmoscope.
von Ruckmann, A., Fitzke, F. W., & Bird, A. C. (1995) · British Journal of Ophthalmology · doi:10.1136/bjo.79.5.407 · Cited by 525
Cited by
Central serous chorioretinopathy: Recent findings and new physiopathology hypothesis
Daruich, A., Matet, A., Dirani, A., Bousquet, E., Zhao, M., Farman, N., Jaisser, F., & Behar-Cohen, F. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.05.003 · Cited by 989
Non-syndromic retinitis pigmentosa
Verbakel, S. K., van Huet, R. A. C., Boon, C. J. F., den Hollander, A. I., Collin, R. W. J., Klaver, C. C. W., Hoyng, C. B., Roepman, R., & Klevering, B. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.03.005 · Cited by 973
The Progression of Geographic Atrophy Secondary to Age-Related Macular Degeneration
Fleckenstein, M., Mitchell, P., Freund, K. B., Sadda, S., Holz, F. G., Brittain, C., Henry, E. C., & Ferrara, D. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.08.038 · Cited by 561
FUNDUS AUTOFLUORESCENCE IMAGING: Review and Perspectives
SCHMITZ-VALCKENBERG, S., HOLZ, F. G., BIRD, A. C., & SPAIDE, R. F. (2008) · Retina · doi:10.1097/iae.0b013e318164a907 · Cited by 537
The susceptibility of the retina to photochemical damage from visible light
Hunter, J. J., Morgan, J. I. W., Merigan, W. H., Sliney, D. H., Sparrow, J. R., & Williams, D. R. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.11.001 · Cited by 355
Cremers, F. P. M., Lee, W., Collin, R. W. J., & Allikmets, R. (2020) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100861 · Cited by 315
Clinical applications of fundus autofluorescence in retinal disease
Yung, M., Klufas, M. A., & Sarraf, D. (2016) · International Journal of Retina and Vitreous · doi:10.1186/s40942-016-0035-x · Cited by 236
Baumann, B., Baumann, S. O., Konegger, T., Pircher, M., Götzinger, E., Schlanitz, F., Schütze, C., Sattmann, H., Litschauer, M., Schmidt-Erfurth, U., et al. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001670 · Cited by 163
Retinal Laminar Architecture in Human Retinitis Pigmentosa Caused by Rhodopsin Gene Mutations
Aleman, T. S., Cideciyan, A. V., Sumaroka, A., Windsor, E. A. M., Herrera, W., White, D. A., Kaushal, S., Naidu, A., Roman, A. J., Schwartz, S. B., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1110 · Cited by 133
Zanzottera, E. C., Messinger, J. D., Ach, T., Smith, R. T., & Curcio, C. A. (2015) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-16432 · Cited by 110
Miura, M., Makita, S., Sugiyama, S., Hong, Y.-J., Yasuno, Y., Elsner, A. E., Tamiya, S., Tsukahara, R., Iwasaki, T., & Goto, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-03529-8 · Cited by 85
Gibbs, D., Cideciyan, A. V., Jacobson, S. G., & Williams, D. S. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3471 · Cited by 82
Lima de Carvalho, J. R., Kim, H. J., Ueda, K., Zhao, J., Owji, A. P., Yang, T., Tsang, S. H., & Sparrow, J. R. (2020) · Journal of Biological Chemistry · doi:10.1074/jbc.ra120.012695 · Cited by 42
The role of tissue fluorescence in in vivo optical bioimaging
Lifante, J., Shen, Y., Ximendes, E., Martín Rodríguez, E., & Ortgies, D. H. (2020) · Journal of Applied Physics · doi:10.1063/5.0021854 · Cited by 43
Oh, J. K., Lima de Carvalho, J. R., Ryu, J., Tsang, S. H., & Sparrow, J. R. (2020) · Scientific Reports · doi:10.1038/s41598-020-65763-x · Cited by 18
Metadata
- Authors
- Keilhauer, C. N., & Delori, F. C.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2006-08-01
- Volume
- 47
- Issue
- 8
- Pages
- 3556
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2059022308
- Cited by
- 397
- References
- 49
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.