The DOI matches its Crossref record.
Diurnal Variation of Axial Length, Intraocular Pressure, and Anterior Eye Biometrics
Open accessAbstract
PURPOSE: To investigate the diurnal variation in axial length and anterior eye biometrics, while simultaneously measuring intraocular pressure (IOP) with dynamic contour tonometry in human subjects. METHODS: Fifteen young adult near-emmetropic subjects had axial length, anterior eye biometrics (central corneal thickness and anterior chamber dimensions), and IOP measured at six different times across a 24-hour measurement period. Repeated-measures ANOVA and sine curve fitting were used to analyze the diurnal rhythms in each measured parameter. RESULTS: Axial length was found to undergo significant diurnal variation (P = 0.0006). The mean amplitude of axial length change was 0.046 +/- 0.022 mm. The mean peak in axial length was found to occur at 1113. Intraocular pressure and ocular pulse amplitude were also found to undergo significant diurnal change (P < 0.0001 and 0.0006, respectively). The variation in axial length exhibited a significant association with the change in IOP (r = 0.37, P = 0.001). No significant difference was found between the mean peak times of axial length and IOP. Anterior eye biometric measures of central corneal thickness and anterior chamber depth were also found to undergo significant diurnal changes (P < 0.0001 and 0.0368, respectively). CONCLUSIONS: Axial length undergoes significant variation over a 24-hour period. Associations exist between the change in axial length and the change in IOP, as measured by dynamic contour tonometry. These results may have significant implications for the role of ocular diurnal rhythms in emmetropization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tan, C. S., Ouyang, Y., Ruiz, H., & Sadda, S. R. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8782 · Cited by 784
IMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
Circadian rhythms, refractive development, and myopia
Chakraborty, R., Ostrin, L. A., Nickla, D. L., Iuvone, P. M., Pardue, M. T., & Stone, R. A. (2018) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12453 · Cited by 235
Metadata
- Authors
- Read, S. A., Collins, M. J., & Iskander, D. R.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2008-07-01
- Volume
- 49
- Issue
- 7
- Pages
- 2911
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1564647356
- Cited by
- 173
- References
- 0
- FWCI
- 8.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.