The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Drug-Eluting Contact Lens
Open accessAbstract
PURPOSE: To formulate and characterize a drug-eluting contact lens designed to provide extended, controlled release of a drug. METHODS: Prototype contact lenses were created by coating PLGA (poly[lactic-co-glycolic acid]) films containing test compounds with pHEMA (poly[hydroxyethyl methacrylate]) by ultraviolet light polymerization. The films, containing encapsulated fluorescein or ciprofloxacin, were characterized by scanning electron microscopy. Release studies were conducted in phosphate-buffered saline at 37 degrees C with continuous shaking. Ciprofloxacin eluted from the contact lens was studied in an antimicrobial assay to verify antimicrobial effectiveness. RESULTS: After a brief and minimal initial burst, the prototype contact lenses demonstrated controlled release of the molecules studied, with zero-order release kinetics under infinite sink conditions for over 4 weeks. The rate of drug release was controlled by changing either the ratio of drug to PLGA or the molecular mass of the PLGA used. Both the PLGA and the pHEMA affected release kinetics. Ciprofloxacin released from the contact lenses inhibited ciprofloxacin-sensitive Staphylococcus aureus at all time-points tested. CONCLUSIONS: A prototype contact lens for sustained drug release consisting of a thin drug-PLGA film coated with pHEMA could be used as a platform for ocular drug delivery with widespread therapeutic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrophilic gels for biological use
WICHTERLE, O., & LÍM, D. (1960) · Nature · doi:10.1038/185117a0 · Cited by 2,996
Cited by
Remotely Triggerable Drug Delivery Systems
Timko, B. P., Dvir, T., & Kohane, D. S. (2010) · Advanced Materials · doi:10.1002/adma.201002072 · Cited by 614
Self-citationYetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Ocular drug delivery: present innovations and future challenges
Gote, V., Sikder, S., Sicotte, J., & Pal, D. (2019) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.119.256933 · Cited by 441
Contact Lens Materials: A Materials Science Perspective
Musgrave, C. S. A., & Fang, F. (2019) · Materials · doi:10.3390/ma12020261 · Cited by 355
Recent advances in materials for extended-release antibiotic delivery system
Gao, P., Nie, X., Zou, M., Shi, Y., & Cheng, G. (2011) · The Journal of Antibiotics · doi:10.1038/ja.2011.58 · Cited by 310
Biocompatibility and drug delivery systems
Kohane, D. S., & Langer, R. (2010) · Chem. Sci. · doi:10.1039/c0sc00203h · Cited by 307
Self-citationAdvances in ophthalmic drug delivery
Morrison, P. W., & Khutoryanskiy, V. V. (2014) · Therapeutic Delivery · doi:10.4155/tde.14.75 · Cited by 196
Metadata
- Authors
- Ciolino, J. B., Hoare, T. R., Iwata, N. G., Behlau, I., Dohlman, C. H., Langer, R., & Kohane, D. S.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2009-07-01
- Volume
- 50
- Issue
- 7
- Pages
- 3346
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1971972063
- Cited by
- 248
- References
- 1
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.