Abstract

PURPOSE: To present the application of a new sensor based on a flexible, highly piezoresistive, nanocomposite, all-organic bilayer (BL) adapted to a contact lens (CL) for non-invasive monitoring intraocular pressure (IOP). METHODS: A prototype of a sensing CL, adapted to a pig eyeball, was tested on different enucleated pig eyes. A rigid, gas-permeable CL was designed as a doughnut shape with a 3-mm hole, where the BL film-based sensor was incorporated. The sensor was a polycarbonate film coated with a polycrystalline layer of the highly piezoresistive molecular conductor β-(ET)₂I₃, which can detect deformations caused by pressure changes of 1 mm Hg. The pig eyeballs were subjected to controlled-pressure variations (low-pressure transducer) to register the electrical resistance response of the CL sensor to pressure changes. Similarly, a CL sensor was designed according to the anatomic characteristics of the eye of a volunteer on the research team. RESULTS: A good correlation (r² = 0.99) was demonstrated between the sensing CL electrical response, and IOP (mm Hg) changes in pig eyes, with a sensitivity of 0.4 Ω/mm Hg. A human eye test also showed the high potential of this new sensor (IOP variations caused by eye massage, blinking, and eye movements were registered). CONCLUSIONS: A new nanostructured sensing CL for continuous monitoring of IOP was validated in an in vitro model (porcine eyeball) and in a human eye. This prototype has adequate sensitivity to continuously monitor IOP. This device will be useful for glaucoma diagnosis and treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-7064

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 48

Metadata

Authors
Sánchez, I., Laukhin, V., Moya, A., Martin, R., Ussa, F., Laukhina, E., Guimera, A., Villa, R., Rovira, C., Aguiló, J., Veciana, J., & Pastor, J. C.
Venue
Investigative Opthalmology & Visual Science
Published
2011-10-21
Volume
52
Issue
11
Pages
8310
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1966647970
Cited by
48
References
3
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prototype of a Nanostructured Sensing Contact Lens for Noninvasive Intraocular Pressure Monitoring. https://app.cochat.ai/papers/10.1167/iovs.10-7064
The paper
Sánchez, I., Laukhin, V., Moya, A., Martin, R., Ussa, F., Laukhina, E., Guimera, A., Villa, R., Rovira, C., Aguiló, J., Veciana, J., & Pastor, J. C. (2011). Prototype of a Nanostructured Sensing Contact Lens for Noninvasive Intraocular Pressure Monitoring. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.10-7064

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.