The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Equivalence of Biomechanical Changes Induced by Rapid and Standard Corneal Cross-linking, Using Riboflavin and Ultraviolet Radiation
Abstract
PURPOSE: Ultraviolet (UV) corneal cross-linking is an accepted method for treating corneal ecstatic disorders. The authors evaluated whether a rapid treatment protocol (higher intensity and shorter irradiation time) could achieve the same increase in corneal stiffness as the currently used standard protocol. METHODS: Stress-strain measurements were performed on porcine corneal strips. The corneas (n = 72) were cut into three strips, each randomly receiving a different treatment: rapid (10 mW/cm(2), 9 minutes), standard (3 mW/cm(2), 30 minutes), or no (control, 0 mW/cm(2)) irradiation. After irradiation, the Young's modulus of each strip was determined. The results of the stress-strain measurements were analyzed statistically. RESULTS: Statistical analysis showed that, after irradiation, the median value of Young's modulus from both active treatment groups (rapid, 3.83 N/mm(2); standard, 3.88 N/mm(2)) was significantly higher (P < 0.05) than that of the control group (2.91 N/mm(2)). Treatment increased Young's modulus by a factor of 1.3. However, there was no significant difference (P = 0.43) between the rapid and standard groups in the median of Young's modulus. CONCLUSIONS: Rapid UV cross-linking treatment can be regarded as equivalent to the standard procedure in terms of increase in corneal stiffness. The new rapid protocol shortens the treatment duration by more than two thirds, from 30 to 9 minutes. The safety of the higher intensities must be addressed in further clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Die Reziprozitätsregel in der Photobiologie
Schindl, A., Rosado-Schlosser, B., & Trautinger, F. (2001) · Der Hautarzt · doi:10.1007/s001050170065 · Cited by 58 · cited 1×
“On the one hand, they support the direct application of the BunsenRoscoe law but, on the other hand, they also show that biological tissues possess a protective mechanism that can be damaged by electromagnetic radiation when the threshold intensity is exceeded for a prolonged period.(18) On the supposition that the Bu…”
Background
Cited by
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
Risk Factors for Progression to Penetrating Keratoplasty in Patients With Keratoconus
Reeves, S. W., Stinnett, S., Adelman, R. A., & Afshari, N. A. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.05.029 · Cited by 290
Wernli, J., Schumacher, S., Spoerl, E., & Mrochen, M. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-11409 · Cited by 263
Self-citationInteraction of ultraviolet light with the cornea: clinical implications for corneal crosslinking
Lombardo, M., Pucci, G., Barberi, R., & Lombardo, G. (2015) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2014.12.013 · Cited by 62
Metadata
- Authors
- Schumacher, S., Oeftiger, L., & Mrochen, M.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-11-24
- Volume
- 52
- Issue
- 12
- Pages
- 9048
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1980795519
- Cited by
- 221
- References
- 1
- FWCI
- 12.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Equivalence of Biomechanical Changes Induced by Rapid and Standard Corneal Cross-linking, Using Riboflavin and Ultraviolet Radiation. https://app.cochat.ai/papers/10.1167/iovs.11-7818
- The paper
- Schumacher, S., Oeftiger, L., & Mrochen, M. (2011). Equivalence of Biomechanical Changes Induced by Rapid and Standard Corneal Cross-linking, Using Riboflavin and Ultraviolet Radiation. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.11-7818
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.