The Cellular Origins of the Outer Retinal Bands in Optical Coherence Tomography Images
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
PURPOSE: To test the recently proposed hypothesis that the second outer retinal band, observed in clinical OCT images, originates from the inner segment ellipsoid, by measuring: (1) the thickness of this band within single cone photoreceptors, and (2) its respective distance from the putative external limiting membrane (band 1) and cone outer segment tips (band 3). METHODS: Adaptive optics-optical coherence tomography images were acquired from four subjects without known retinal disease. Images were obtained at foveal (2°) and perifoveal (5°) locations. Cone photoreceptors (n = 9593) were identified and segmented in three dimensions using custom software. Features corresponding to bands 1, 2, and 3 were automatically identified. The thickness of band 2 was assessed in each cell by fitting the longitudinal reflectance profile of the band with a Gaussian function. Distances between bands 1 and 2, and between 2 and 3, respectively, were also measured in each cell. Two independent calibration techniques were employed to determine the depth scale (physical length per pixel) of the imaging system. RESULTS: When resolved within single cells, the thickness of band 2 is a factor of three to four times narrower than in corresponding clinical OCT images. The distribution of band 2 thickness across subjects and eccentricities had a modal value of 4.7 μm, with 48% of the cones falling between 4.1 and 5.2 μm. No significant differences were found between cells in the fovea and perifovea. The distance separating bands 1 and 2 was found to be larger than the distance between bands 2 and 3, across subjects and eccentricities, with a significantly larger difference at 5° than 2°. CONCLUSIONS: On the basis of these findings, we suggest that ascription of the outer retinal band 2 to the inner segment ellipsoid is unjustified, because the ellipsoid is both too thick and proximally located to produce the band.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167 · cited 1×
“Both reveal regular mosaics of the overlapping bright spots24 whose spacing agrees with histologic measurements of cone photoreceptors.(78) At both layers, reflected light appears to be confined, laterally, to the interior of the cell.”
BackgroundPhotosensitivity in optical fiber waveguides: Application to reflection filter fabrication
Hill, K. O., Fujii, Y., Johnson, D. C., & Kawasaki, B. S. (1978) · Applied Physics Letters · doi:10.1063/1.89881 · Cited by 2,250
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854 · cited 1×
“00021% requires 57 dB of sensitivity to observe, a number well within the theoretical and measured sensitivities of SDOCT systems.(40,42) A comparable SD-OCT system was measured to have a sensitivity of 98.”
BackgroundSensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794 · cited 1×
“00021% requires 57 dB of sensitivity to observe, a number well within the theoretical and measured sensitivities of SDOCT systems.(40,42) A comparable SD-OCT system was measured to have a sensitivity of 98.”
BackgroundImaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Fung, A. E., Lalwani, G. A., Rosenfeld, P. J., Dubovy, S. R., Michels, S., Feuer, W. J., Puliafito, C. A., Davis, J. L., Flynn, H. W., & Esquiabro, M. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.01.028 · Cited by 972
Cited by
Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited]
Pircher, M., & Zawadzki, R. J. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002536 · Cited by 209
Self-citationAdaptive Optics Ophthalmoscopy
Roorda, A., & Duncan, J. L. (2015) · Annual Review of Vision Science · doi:10.1146/annurev-vision-082114-035357 · Cited by 168
“For example, the cone photoreceptor contains two relatively discrete reflections: one from near the inner segment–outer segment junction and one from the cone outer segment tips (COST) ( Jonnal et al. 2014).”
Nti, A. A., Serrano, L. W., Sandhu, H. S., Uyhazi, K. E., Edelstein, I. D., Zhou, E. J., Bowman, S., Song, D., Gangadhar, T. C., Schuchter, L. M., et al. (2019) · Retina · doi:10.1097/iae.0000000000002027 · Cited by 31
Metadata
- Authors
- Jonnal, R. S., Kocaoglu, O. P., Zawadzki, R. J., Lee, S.-H., Werner, J. S., & Miller, D. T.
- Venue
- Investigative Ophthalmology & Visual Science
- Published
- 2014-10-16
- Volume
- 55
- Issue
- 12
- Pages
- 7904-7918
- ISSN
- 0146-0404 (ISSN-L)
- OpenAlex
- W2318697049
- Cited by
- 169
- References
- 72
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.