CoChat

Quantitative SD-OCT Imaging Biomarkers as Indicators of Age-Related Macular Degeneration Progression

de Sisternes, Luis, Simon, Noah, Tibshirani, Robert, Leng, Theodore, Rubin, Daniel L. · 2014 · Investigative Opthalmology & Visual Science
Cited by 142

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

PURPOSE: We developed a statistical model based on quantitative characteristics of drusen to estimate the likelihood of conversion from early and intermediate age-related macular degeneration (AMD) to its advanced exudative form (AMD progression) in the short term (less than 5 years), a crucial task to enable early intervention and improve outcomes. METHODS: Image features of drusen quantifying their number, morphology, and reflectivity properties, as well as the longitudinal evolution in these characteristics, were automatically extracted from 2146 spectral-domain optical coherence tomography (SD-OCT) scans of 330 AMD eyes in 244 patients collected over a period of 5 years, with 36 eyes showing progression during clinical follow-up. We developed and evaluated a statistical model to predict the likelihood of progression at predetermined times using clinical and image features as predictors. RESULTS: Area, volume, height, and reflectivity of drusen were informative features distinguishing between progressing and nonprogressing cases. Discerning progression at follow-up (mean, 6.16 months) resulted in a mean area under the receiver operating characteristic curve (AUC) of 0.74 (95% confidence interval [CI], 0.58, 0.85). The maximum predictive performance was observed at 11 months after a patient's first early AMD diagnosis, with mean AUC 0.92 (95% CI, 0.83, 0.98). Those eyes predicted to progress showed a much higher progression rate than those predicted not to progress at any given time from the initial visit. CONCLUSIONS: Our results demonstrate the potential ability of our model to identify those AMD patients at risk of progressing to exudative AMD from an early or intermediate stage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.14-14918

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 142

Metadata

Authors
de Sisternes, L., Simon, N., Tibshirani, R., Leng, T., & Rubin, D. L.
Venue
Investigative Opthalmology & Visual Science
Published
2014-11-05
Volume
55
Issue
11
Pages
7093
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2322965718
Cited by
142
References
10
FWCI
11.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative SD-OCT Imaging Biomarkers as Indicators of Age-Related Macular Degeneration Progression. https://app.cochat.ai/papers/10.1167/iovs.14-14918
The paper
de Sisternes, L., Simon, N., Tibshirani, R., Leng, T., & Rubin, D. L. (2014). Quantitative SD-OCT Imaging Biomarkers as Indicators of Age-Related Macular Degeneration Progression. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.14-14918

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.