CoChat

A Double-Blind, Placebo-Controlled Study on the Effects of Lutein and Zeaxanthin on Photostress Recovery, Glare Disability, and Chromatic Contrast

Hammond, B. R., Fletcher, L. M., Roos, F., Wittwer, J., Schalch, W. · 2014 · Investigative Ophthalmology & Visual Science
Cited by 119

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: Past studies have shown that higher macular pigment optical density (MPOD) and lutein (L) and zeaxanthin (Z) supplementation are related to improvements in glare disability, photostress recovery, and chromatic contrast. This study assessed those links using a randomized, double-blind, placebo-controlled design. METHODS: The visual effects of 1 year of supplementing L (10 mg/d) and Z (2 mg/d) were investigated. One hundred fifteen young, healthy subjects were recruited and randomized into the study (58 received placebo, 57 L+Z). Several dependent measures were collected at baseline and then once every 3 months: serum L and Z measured by HPLC chromatography; MPOD measured using customized heterochromatic flicker photometry; photostress recovery assessed by measuring the time needed to recover visual acquisition of a grating target after 30 seconds of an intense xenon white flash exposure; glare disability evaluated as the energy in a surrounding annulus necessary to veil a central grating target; and chromatic contrast assessed by measuring thresholds for a yellow grating target superposed on a 460-nm background. RESULTS: Macular pigment optical density increased significantly versus placebo at all eccentricities (10, 30, 60, and 105 minutes from the center of the macula). Serum L and Z also increased significantly by the first follow-up visit (at 3 months), and remained elevated throughout the intervention period of 1 year. Chromatic contrast and photostress recovery time improved significantly versus placebo. Glare disability was correlated with macular pigment density throughout the study period but did not increase significantly in the treated group. CONCLUSIONS: Daily supplementation with L+Z resulted in significant increase in serum levels and MPOD and improvements in chromatic contrast and recovery from photostress. These results are consistent with past studies showing that increasing MPOD leads to improved visual performance. (ClinicalTrials.gov number, NCT00909090.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.14-15573

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Hammond, B. R., Fletcher, L. M., Roos, F., Wittwer, J., & Schalch, W.
Venue
Investigative Ophthalmology & Visual Science
Published
2014-12-02
Volume
55
Issue
12
Pages
8583-8589
ISSN
0146-0404 (ISSN-L)
OpenAlex
W2003993240
Cited by
119
References
2
FWCI
5.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.