CoChat

Early Detection of Amyloidopathy in Alzheimer's Mice by Hyperspectral Endoscopy

Open access
More, Swati S., Beach, James M., Vince, Robert · 2016 · Investigative Opthalmology & Visual Science
Cited by 93

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

PURPOSE: To describe a spectral imaging system for small animal studies based on noninvasive endoscopy of the retina, and to present time-resolved spectral changes from live Alzheimer's mice prior to cognitive decline, corroborating our previous in vitro findings. METHODS: Topical endoscope fundus imaging was modified to use a machine vision camera and tunable wavelength system for acquiring monochromatic images across the visible to near-infrared spectral range. Alzheimer's APP/PS1 mice and age-matched, wild-type mice were imaged monthly from months 3 through 8 to assess changes in the fundus reflection spectrum. Optical changes were fit to Rayleigh light scatter models as measures of amyloid aggregation. RESULTS: Good quality spectral images of the central retina were obtained. Short-wavelength reflectance from Alzheimer's mice retinae showed significant reduction over time compared to wild-type mice. Optical changes were consistent with an increase in Rayleigh light scattering in neural retina due to soluble Aβ1-42 aggregates. The changes in light scatter showed a monotonic increase in soluble amyloid aggregates over a 6-month period, with significant build up occurring at 7 months. CONCLUSIONS: Hyperspectral imaging technique can be brought inexpensively to the study of retinal changes caused by Alzheimer's disease progression in live small animals. A similar previous finding of reduction in the light reflection over a range of wavelengths in isolated Alzheimer's mice retinae, was reproducible in the living Alzheimer's mice. The technique presented here has a potential for development as an early Alzheimer's retinal diagnostic test in humans, which will support the treatment outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.15-17406

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 93

Metadata

Authors
More, S. S., Beach, J. M., & Vince, R.
Venue
Investigative Opthalmology & Visual Science
Published
2016-06-22
Volume
57
Issue
7
Pages
3231
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2462668417
Cited by
93
References
6
FWCI
9.72
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early Detection of Amyloidopathy in Alzheimer's Mice by Hyperspectral Endoscopy. https://app.cochat.ai/papers/10.1167/iovs.15-17406
The paper
More, S. S., Beach, J. M., & Vince, R. (2016). Early Detection of Amyloidopathy in Alzheimer's Mice by Hyperspectral Endoscopy. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.15-17406

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.