Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Evidence for Cerebrospinal Fluid Entry Into the Optic Nerve via a Glymphatic Pathway

Open access
Mathieu, Emily, Gupta, Neeru, Ahari, Amir, Zhou, Xun, Hanna, Joseph, Yücel, Yeni H. · 2017 · Investigative Opthalmology & Visual Science

Abstract

Purpose: The purpose of this study was to determine whether cerebrospinal fluid (CSF) enters the optic nerve via a glymphatic pathway and whether this entry is size-dependent. Methods: Fluorescent dextran tracers (fluorescein isothiocyanate [FITC]) of four different sizes (10, 40, 70, and 500 kDa) and FITC-ovalbumin (45 kDa) were injected into the CSF of 15 adult mice. Tracer distribution in the orbital optic nerve at 1 hour after injection was assessed in tissue sections with confocal microscopy. Tracer distribution within the optic nerve was studied in relation to blood vessels and astrocytes identified by isolectin histochemistry and glial fibrillary acidic protein (GFAP) immunofluorescence, respectively. Aquaporin 4 (AQP4) immunostaining was performed to assess astrocytic endfeet in relation to CSF tracer. Results: One hour following tracer injection into CSF, all tracer sizes (10-500 kDa) were noted in the subarachnoid space surrounding the orbital optic nerve. In all cases, 10 kDa (n = 4/4) and 40 kDa (n = 3/3) tracers were noted within the optic nerve, while 70-kDa tracer was occasionally noted (n = 1/4). Tracer found within the nerve was specifically localized between isolectin-labeled blood vessels and GFAP-positive astrocytes or AQP4-labeled astrocytic endfeet. The 500-kDa tracer was not detected within the optic nerve. Conclusions: To our knowledge, this is the first evidence of a glymphatic pathway in the optic nerve. CSF enters the optic nerve via spaces surrounding blood vessels, bordered by astrocytic endfeet. CSF entry into paravascular spaces of the optic nerve is size-dependent, and this pathway may be highly relevant to optic nerve diseases, including glaucoma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.17-22290

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Mathieu, E., Gupta, N., Ahari, A., Zhou, X., Hanna, J., & Yücel, Y. H.
Venue
Investigative Opthalmology & Visual Science
Published
2017-09-21
Volume
58
Issue
11
Pages
4784
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2741571643
Cited by
170
References
6
FWCI
4.81
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.