Deep Learning for Predicting Refractive Error From Retinal Fundus Images

Open access
Varadarajan, Avinash V., Poplin, Ryan, Blumer, Katy, Angermueller, Christof, Ledsam, Joe, Chopra, Reena, Keane, Pearse A., Corrado, Greg S., Peng, Lily, Webster, Dale R. · 2018 · Investigative Opthalmology & Visual Science

Abstract

Purpose: We evaluate how deep learning can be applied to extract novel information such as refractive error from retinal fundus imaging. Methods: Retinal fundus images used in this study were 45- and 30-degree field of view images from the UK Biobank and Age-Related Eye Disease Study (AREDS) clinical trials, respectively. Refractive error was measured by autorefraction in UK Biobank and subjective refraction in AREDS. We trained a deep learning algorithm to predict refractive error from a total of 226,870 images and validated it on 24,007 UK Biobank and 15,750 AREDS images. Our model used the "attention" method to identify features that are correlated with refractive error. Results: The resulting algorithm had a mean absolute error (MAE) of 0.56 diopters (95% confidence interval [CI]: 0.55-0.56) for estimating spherical equivalent on the UK Biobank data set and 0.91 diopters (95% CI: 0.89-0.93) for the AREDS data set. The baseline expected MAE (obtained by simply predicting the mean of this population) was 1.81 diopters (95% CI: 1.79-1.84) for UK Biobank and 1.63 (95% CI: 1.60-1.67) for AREDS. Attention maps suggested that the foveal region was one of the most important areas used by the algorithm to make this prediction, though other regions also contribute to the prediction. Conclusions: To our knowledge, the ability to estimate refractive error with high accuracy from retinal fundus photos has not been previously known and demonstrates that deep learning can be applied to make novel predictions from medical images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.18-23887

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 180

Metadata

Authors
Varadarajan, A. V., Poplin, R., Blumer, K., Angermueller, C., Ledsam, J., Chopra, R., Keane, P. A., Corrado, G. S., Peng, L., & Webster, D. R.
Venue
Investigative Opthalmology & Visual Science
Published
2018-06-04
Volume
59
Issue
7
Pages
2861
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2778027947
Cited by
180
References
9
FWCI
9.29
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep Learning for Predicting Refractive Error From Retinal Fundus Images. https://app.cochat.ai/papers/10.1167/iovs.18-23887
The paper
Varadarajan, A. V., Poplin, R., Blumer, K., Angermueller, C., Ledsam, J., Chopra, R., Keane, P. A., Corrado, G. S., Peng, L., & Webster, D. R. (2018). Deep Learning for Predicting Refractive Error From Retinal Fundus Images. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.18-23887

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.