The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Prediction of Individual Disease Conversion in Early AMD Using Artificial Intelligence
Open accessAbstract
Purpose: While millions of individuals show early age-related macular degeneration (AMD) signs, yet have excellent vision, the risk of progression to advanced AMD with legal blindness is highly variable. We suggest means of artificial intelligence to individually predict AMD progression. Methods: In eyes with intermediate AMD, progression to the neovascular type with choroidal neovascularization (CNV) or the dry type with geographic atrophy (GA) was diagnosed based on standardized monthly optical coherence tomography (OCT) images by independent graders. We obtained automated volumetric segmentation of outer neurosensory layers and retinal pigment epithelium, drusen, and hyperreflective foci by spectral domain-OCT image analysis. Using imaging, demographic, and genetic input features, we developed and validated a machine learning-based predictive model assessing the risk of conversion to advanced AMD. Results: Of a total of 495 eyes, 159 eyes (32%) had converted to advanced AMD within 2 years, 114 eyes progressed to CNV, and 45 to GA. Our predictive model differentiated converting versus nonconverting eyes with a performance of 0.68 and 0.80 for CNV and GA, respectively. The most critical quantitative features for progression were outer retinal thickness, hyperreflective foci, and drusen area. The features for conversion showed pathognomonic patterns that were distinctly different for the neovascular and the atrophic pathways. Predictive hallmarks for CNV were mostly drusen-centric, while GA markers were associated with neurosensory retina and age. Conclusions: Artificial intelligence with automated analysis of imaging biomarkers allows personalized prediction of AMD progression. Moreover, pathways of progression may be specific in respect to the neovascular/atrophic type.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vos, T., Allen, C., Arora, M., Barber, R. M., Bhutta, Z. A., Brown, A., Carter, A., Casey, D. C., Charlson, F. J., Chen, A. Z., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31678-6 · Cited by 7,253
Seven-Year Outcomes in Ranibizumab-Treated Patients in ANCHOR, MARINA, and HORIZON
Rofagha, S., Bhisitkul, R. B., Boyer, D. S., Sadda, S. R., & Zhang, K. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.03.046 · Cited by 1,023
A Simplified Severity Scale for Age-Related Macular Degeneration: AREDS Report No. 18
(2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.11.1570 · Cited by 807
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Self-citationZanzottera, E. C., Messinger, J. D., Ach, T., Smith, R. T., Freund, K. B., & Curcio, C. A. (2015) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-16431 · Cited by 164
The Neovascular Age-Related Macular Degeneration Database
Zarranz-Ventura, J., Liew, G., Johnston, R. L., Xing, W., Akerele, T., McKibbin, M., Downey, L., Natha, S., Chakravarthy, U., Bailey, C., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.04.026 · Cited by 103
Cited by
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Introduction to Machine Learning, Neural Networks, and Deep Learning.
Choi, R. Y., Coyner, A. S., Kalpathy–Cramer, J., Chiang, M. F., & Campbell, J. P. (2020) · PubMed · doi:10.1167/tvst.9.2.14 · Cited by 1,012
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
Self-citationDeep learning in ophthalmology: The technical and clinical considerations
Ting, D. S. W., Peng, L., Varadarajan, A. V., Keane, P. A., Burlina, P. M., Chiang, M. F., Schmetterer, L., Pasquale, L. R., Bressler, N. M., Webster, D. R., et al. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.04.003 · Cited by 534
Metadata
- Authors
- Schmidt-Erfurth, U., Waldstein, S. M., Klimscha, S., Sadeghipour, A., Hu, X., Gerendas, B. S., Osborne, A., & Bogunovic, H.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2018-07-02
- Volume
- 59
- Issue
- 8
- Pages
- 3199
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2844103009
- Cited by
- 215
- References
- 6
- FWCI
- 13.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.