Cited by 8Neuroscience and Neural EngineeringTactile and Sensory InteractionsPain Management and Treatment

Contributed Session III: Characteristics of electrically-induced visual percepts in the first human with the Intracortical Visual Prosthesis

Open access
Barry, Michael P, Sadeghi, Roksana, Towle, Vernon L, Stipp, Kelsey, Grant, Patricia, Lane, Frank John, Szlyk, Janet P, Dagnelie, Gislin +1 more·2023·Journal of Vision

Abstract

The Intracortical Visual Prosthesis (ICVP) consists of multiple wireless floating microelectrode arrays (WFMAs), each with 16 stimulating electrodes. Stimulation of these electrodes can potentially provide artificial vision for people who are blind. Twenty-five WFMAs were implanted in the right occipital visual cortex of a participant in an FDA-approved, NIH-sponsored Phase 1 clinical trial (NCT04634383). Here, we report characteristics of visual percepts elicited by the WFMAs (frequency: 200 Hz, cathodic phase duration: 200 µs, amplitude and train length up to 60 µA and 900 ms). Stimulation of single electrodes in 10 WFMAs and groups of 4 or more electrodes in 7 additional WFMAs consistently produced percepts during >10 sessions across approximately 3 months of testing. Phosphenes generated within a single WFMA were typically similar in appearance. Descriptions included configurations of rings, bright or dark dots, and constant or flickering bars, with sizes of 0.3–12° across. Phosphenes appeared as blueish-white, or occasionally orange, red, or having an iridescent texture. Ten WFMAs produced phosphenes within a 4° cluster centered 4° below and to the left of fixation. Phosphenes from 4 other WFMAs were located 4° below or 20° left of the cluster. When using these phosphenes to scan a virtual line, the participant was able to discriminate horizontal and vertical lines (46/51 correct, p < 10^−8, binomial test), and 45° and 135° diagonal lines (12/14 correct, p < 0.01).

Integrity signals

Registry

Crossref · 10.1167/jov.23.11.35

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Barry, M. P., Sadeghi, R., Towle, V. L., Stipp, K., Grant, P., Lane, F. J., Szlyk, J. P., Dagnelie, G., & Troyk, P. R.
Affiliations
  • Illinois Institute of Technology (US)
  • Johns Hopkins University (US)
  • University of Chicago (US)
  • The Chicago Lighthouse for People Who Are Blind or Visually Impaired
Venue
Journal of Vision
Published
2023-09-01
Volume
23
Issue
11
Pages
35
ISSN
1534-7362 (ISSN-L)
OpenAlex
W4386923558
Cited by
8
References
0
Citations by year
2026: 2 · 2025: 3 · 2024: 2 · 2023: 1
FWCI
0.97
Type
journal article
Language
en
Open access
Locations
Journal of Vision (publishedVersion, cc-by-nc-nd)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
Keywords
phosphenes, visual percepts, electrode stimulation, line orientation discrimination, visual exploration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review