Contributed Session III: Characteristics of electrically-induced visual percepts in the first human with the Intracortical Visual Prosthesis
Open accessAbstract
The Intracortical Visual Prosthesis (ICVP) consists of multiple wireless floating microelectrode arrays (WFMAs), each with 16 stimulating electrodes. Stimulation of these electrodes can potentially provide artificial vision for people who are blind. Twenty-five WFMAs were implanted in the right occipital visual cortex of a participant in an FDA-approved, NIH-sponsored Phase 1 clinical trial (NCT04634383). Here, we report characteristics of visual percepts elicited by the WFMAs (frequency: 200 Hz, cathodic phase duration: 200 µs, amplitude and train length up to 60 µA and 900 ms). Stimulation of single electrodes in 10 WFMAs and groups of 4 or more electrodes in 7 additional WFMAs consistently produced percepts during >10 sessions across approximately 3 months of testing. Phosphenes generated within a single WFMA were typically similar in appearance. Descriptions included configurations of rings, bright or dark dots, and constant or flickering bars, with sizes of 0.3–12° across. Phosphenes appeared as blueish-white, or occasionally orange, red, or having an iridescent texture. Ten WFMAs produced phosphenes within a 4° cluster centered 4° below and to the left of fixation. Phosphenes from 4 other WFMAs were located 4° below or 20° left of the cluster. When using these phosphenes to scan a virtual line, the participant was able to discriminate horizontal and vertical lines (46/51 correct, p < 10^−8, binomial test), and 45° and 135° diagonal lines (12/14 correct, p < 0.01).
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In simulations, nearby electrodes are not spatially resolvable.
“Consistent with preliminary data86, our simulations predict that nearby electrodes are not spatially resolvable.”
From A virtual patient simulation modeling the neural and perceptual effects of human visual cortical stimulation, from pulse trains to percepts (2024) · cites this paper as [86]
An electrode array arranged regularly on the cortical surface over-tiles electrodes within the fovea, producing a cluster of heavily overlapping receptive fields within the fovea.
“Figure 8B shows electrodes arranged regularly on the cortical surface. This configuration suffers from the opposite problem—an over-tiling of electrodes within the fovea, producing a cluster of heavily overlapping receptive fields within the fovea, as has been informally observed in one recent study86.”
From A virtual patient simulation modeling the neural and perceptual effects of human visual cortical stimulation, from pulse trains to percepts (2024) · cites this paper as [86]
Cited by
Sorted by citations
Fine, I., & Boynton, G. M. (2024) · Scientific Reports · doi:10.1038/s41598-024-65337-1 · Cited by 19 · see citing works
Visual Prostheses in the Era of Artificial Intelligence Technology
Sarbout, I., Gungor, A., Ounissi, M., Zaher, S., Ptito, M., Kupers, R., Racoceanu, D., & Milea, D. (2025) · Eye and Brain · doi:10.2147/eb.s524322 · Cited by 3 · see citing works
“46 47–49 Despite these developments, there are no commercially available RCP devices to date.”
- Authors
- Barry, M. P., Sadeghi, R., Towle, V. L., Stipp, K., Grant, P., Lane, F. J., Szlyk, J. P., Dagnelie, G., & Troyk, P. R.
- Affiliations
- Illinois Institute of Technology (US)
- Johns Hopkins University (US)
- University of Chicago (US)
- The Chicago Lighthouse for People Who Are Blind or Visually Impaired
- Venue
- Journal of Vision
- Published
- 2023-09-01
- Volume
- 23
- Issue
- 11
- Pages
- 35
- ISSN
- 1534-7362 (ISSN-L)
- OpenAlex
- W4386923558
- Cited by
- 8
- References
- 0
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 1
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Vision (publishedVersion, cc-by-nc-nd)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- phosphenes, visual percepts, electrode stimulation, line orientation discrimination, visual exploration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review