The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Pulmonary mechanics by spectral analysis of forced random noise.
Open accessAbstract
The magnitude (Zrs) and phase angle (thetars) of the total respiratory impedance (Zrs), from 3 to 45 Hz, were rapidly obtained by a modification of the forced oscillation method, in which a random noise pressure wave is imposed on the respiratory system at the mouth and compared to the induced random flow using Fourier and spectral analysis. No significant amplitude or phase errors were introduced by the instrumentation. 10 normals, 5 smokers, and 5 patients with chronic obstructive lung disease (COPD) were studied. Measurements of Zrs were corrected for the parallel shunt impedance of the mouth, which was independently measured during a Valsalva maneuver, and from which the mechanical properties of the mouth were derived. There were small differences in Zrs between normals and smokers but both behaved approximately like a second-order system with thetars = 0 degree in the range of 5--9 Hz, and thetars in the range of +40 degrees at 20 Hz and +60 degrees at 40 Hz. In COPD, thetars remained more negative (compared to normals and smokers) at all frequencies and crossed 0 between 15 and 29 Hz. Changes in Zrs, similar in those in COPD, were also observed at low lung volumes in normals. These changes, the effects of a bronchodilator in COPD, and deviations of Zrs from second-order behavior in normals, can best be explained by a two-compartment parallel model, in which time-constant discrepancies between the lung parenchyma and compliant airway keep compliant greater than inertial reactance, resulting in a more negative phase angle as frequency is increased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Spectral Analysis and its Applications.
Freiberger, W. F., Jenkins, G. M., & Watts, D. G. (1969) · Journal of the American Statistical Association · doi:10.2307/2286100 · Cited by 4,981
The Measurement of Power Spectra
Blackman, R. B., Tukey, J. W., & Teichmann, T. (1960) · Physics Today · doi:10.1063/1.3056826 · Cited by 1,843
Measurement and Analysis of Random Data
Bendat, A. G., & Bendat, J. S. (1966) · Cited by 1,231
Mechanical Factors in Distribution of Pulmonary Ventilation
Otis, A. B., McKerrow, C. B., Bartlett, R. A., Mead, J., McIlroy, M. B., Selverstone, N. J., & Radford, E. P. (1956) · Journal of Applied Physiology · doi:10.1152/jappl.1956.8.4.427 · Cited by 1,015
Oscillation Mechanics of Lungs and Chest in Man
DuBois, A. B., Brody, A. W., Lewis, D. H., & Burgess, B. F. (1956) · Journal of Applied Physiology · doi:10.1152/jappl.1956.8.6.587 · Cited by 814
Measurement and Analysis of Random Data
Jackson, R. (1967) · Physics Bulletin · doi:10.1088/0031-9112/18/7/023 · Cited by 783
Resistance of central and peripheral airways measured by a retrograde catheter
Macklem, P. T., & Mead, J. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.22.3.395 · Cited by 741
A guided tour of the fast Fourier transform
Bergland, G. D. (1969) · IEEE Spectrum · doi:10.1109/mspec.1969.5213896 · Cited by 673
Frequency dependence of compliance as a test for obstruction in the small airways
Woolcock, A. J., Vincent, N. J., & Macklem, P. T. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106066 · Cited by 436
Frequency dependence of flow resistance in patients with obstructive lung disease
Grimby, G., Takishima, T., Graham, W., Macklem, P. T., & Mead, J. (1968) · Journal of Clinical Investigation · doi:10.1172/jci105837 · Cited by 311
THE MECHANICAL PROPERTIES OF THE LUNGS IN EMPHYSEMA 1
Mead, J., Lindgren, I., & Gaensler, E. A. (1955) · Journal of Clinical Investigation · doi:10.1172/jci103150 · Cited by 224
Effective measurements using digital signal analysis
Roth, P. R. (1971) · IEEE Spectrum · doi:10.1109/mspec.1971.5218046 · Cited by 212
The resistance of collateral channels in excised human lungs
Hogg, J. C., Macklem, P. T., & Thurlbeck, W. M. (1969) · Journal of Clinical Investigation · doi:10.1172/jci105999 · Cited by 144
Taylor, M. G. (1966) · Circulation Research · doi:10.1161/01.res.18.5.585 · Cited by 121
Linearity and frequency response of pneumotachographs
Finucane, K. E., Egan, B., & Dawson, S. V. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.32.1.121 · Cited by 114
Comparison of some methods used for process identification
Cuenod, M., & Sage, A. P. (1968) · Automatica · doi:10.1016/0005-1098(68)90016-2 · Cited by 73
Total Respiratory Inertance and Its Gas and Tissue Components in Normal and Obese Men *
Sharp, J. T., Henry, J. P., Sweany, S. K., Meadows, W. R., & Pietras, R. J. (1964) · Journal of Clinical Investigation · doi:10.1172/jci104936 · Cited by 65
Comparative sensitivity of four methods for measuring changes in respiratory flow resistance in man
Frank, N. R., Mead, J., & Whittenberger, J. L. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.6.934 · Cited by 62
Frequency-dependent compliance at different levels of inspiration in normal adults
Mills, R. J., Cumming, G., & Harris, P. (1963) · Journal of Applied Physiology · doi:10.1152/jappl.1963.18.6.1061 · Cited by 30
A New Method for Studying Mechanics of Breathing Using Cathode Ray Oscillograph.
DuBoist, A. B., & Ross, B. B. (1951) · Experimental Biology and Medicine · doi:10.3181/00379727-78-19135 · Cited by 21
Cited by
Oostveen, E., MacLeod, D., Lorino, H., Farré, R., Hantos, Z., Desager, K., & Marchal, F. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00089403 · Cited by 1,302
Beydon, N., Davis, S. D., Lombardi, E., Allen, J. L., Arets, H. G. M., Aurora, P., Bisgaard, H., Davis, G. M., Ducharme, F. M., Eigen, H., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200605-642st · Cited by 1,250
Technical standards for respiratory oscillometry
King, G. G., Bates, J., Berger, K. I., Calverley, P., de Melo, P. L., Dellacà, R. L., Farré, R., Hall, G. L., Ioan, I., Irvin, C. G., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.00753-2019 · Cited by 756
Effects of Obesity on Respiratory Resistance
Zerah, F., Harf, A., Perlemuter, L., Lorino, H., Lorino, A.-M., & Atlan, G. (1993) · Chest · doi:10.1378/chest.103.5.1470 · Cited by 450
Metadata
- Authors
- Michaelson, E. D., Grassman, E. D., & Peters, W. R.
- Venue
- Journal of Clinical Investigation
- Published
- 1975-11-01
- Volume
- 56
- Issue
- 5
- Pages
- 1210-1230
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2111165326
- Cited by
- 410
- References
- 21
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.