CoChat

Pattern of insulin delivery after intravenous glucose injection in man and its relation to plasma glucose disappearance.

Open access
Ferrannini, E, Pilo, A · 1979 · Journal of Clinical Investigation
Cited by 41

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Plasma insulin concentrations after pulse intravenous injection of glucose show an early rise, which declines towards the prestimulation level smoothly. This pattern is the effect of both continuing secretion and hormone disappearance from the plasma. To reconstruct the time-course of the acutal secretory response, we measured insulin disappearance from the plasma of 17 healthy volunteers by means of a bolus intravenous injection of 125I-insulin, and then performed an intravenous glucose tolerance test with frequent blood sampling. The data were analyzed by deconvolution, which made it possible to compute the glucose-induced posthepatic insulin delivery rate minute by minute. Under basal conditions, 2.64 +/- 0.28 (mean +/-SEM) mU/min.m2 reaches the systemic circulation. In the 90 min that follow acute glucose stimulation, 0.86 +/- 0.11 U/m2, a 270% increment over the basal production rate, is made available to the periphery. A wide individual variability was found to exist in both the basal and the glucose-stimulated delivery. They were strongly (P less than 0.001) related to each other in a direct fashion. A first spike of insulin release (107 +/- 12 mU/min) occurred in all the subjects at 2.2 +/- 0.2 min followed, in 16 subjects, by a second spike (38 +/- 6 mU/min), at 11.3 +/- 0.9 min. Two-thirds of the total postglucose insulin output were associated with the initial, oscillatory phase (from 0 to 25 min, on average), and one-third with the "tail" phase (from 25 to 90 min), during which the average delivery rate was 5.0 +/- 0.9 mU/min.m2. The delivery curves were closely (mean squared deviation of 4.5 +/- 0.5 mU/min) reproduced by computer stimulation upon assuming that insulin secretion is a function of both glucose concentration and glucose rate of change. Both the first and the second spike of insulin delivery, but not the total insulin output during the test, showed a significant, positive correlation with the plasma glucose disappearance rate computed between 10 and 60 min. Furthermore, with a time shift of approximately equal to 15 min, a significant relationship between the phases of insulin secretion and the glucose decay rates, computed over corresponding time intervals, was evident throughout the test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci109445

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 41

Metadata

Authors
Ferrannini, E., & Pilo, A.
Venue
Journal of Clinical Investigation
Published
1979-07-01
Volume
64
Issue
1
Pages
243-254
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2052861702
Cited by
41
References
5
FWCI
1.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.