Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 246

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Effect of synthetic ovine corticotropin-releasing factor. Dose response of plasma adrenocorticotropin and cortisol.

Open access
Orth, D N, Jackson, R V, DeCherney, G S, DeBold, C R, Alexander, A N, Island, D P, Rivier, J, Rivier, C, Spiess, J, Vale, W·1983·Journal of Clinical Investigation

Abstract

Synthetic ovine corticotropin-releasing factor (CRF) was administered to normal male volunteer subjects as an intravenous bolus or 30-s infusion. Doses of CRF ranging from 0.001 to 30 micrograms/kg body wt were administered, and plasma immunoreactive (IR)-ACTH and IR-cortisol concentrations were measured. The threshold dose appeared to be 0.01-0.03 micrograms/kg, the half-maximal dose 0.3-1 micrograms/kg, and the maximally effective dose 3-10 micrograms/kg. Basal concentrations of IR-ACTH and IR-cortisol were 14 +/- 7.6 pg/ml (mean +/- SD) and 5.6 +/- 2.2 micrograms/dl, respectively. IR-ACTH rose as early as 2 min after CRF injection, reached peak levels in 10-15 min, and declined slowly thereafter. IR-cortisol rose at 10 min or later and reached peak levels in 30-60 min. At a dose of 30 micrograms/kg, neither IR-ACTH nor IR-cortisol fell from peak levels of 82 +/- 21 pg/ml (mean +/- SE) and 23 +/- 1.4 micrograms/dl, respectively, during the 2-h course of the experiment, indicating that CRF has a sustained effect on ACTH release and/or a prolonged circulating plasma half-life. There was little or no increase in the levels of other anterior pituitary hormones. At doses of 1 microgram/kg and higher, facial flushing, tachycardia, and, in some subjects, a 15-29-mmHg decline in systemic arterial blood pressure were observed, even though blood volume was replaced and the subjects remained supine. These data indicate that synthetic ovine CRF is a very potent and specific ACTH secretagogue in man. Administered with caution until its vasomotor effects are more fully defined, CRF promises to be a safe and very useful investigative, diagnostic, and, possibly, therapeutic agent in man.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci110804

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 246

Metadata

Authors
Orth, D. N., Jackson, R. V., DeCherney, G. S., DeBold, C. R., Alexander, A. N., Island, D. P., Rivier, J., Rivier, C., Spiess, J., & Vale, W.
Venue
Journal of Clinical Investigation
Published
1983-03-01
Volume
71
Issue
3
Pages
587-595
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2073388455
Cited by
246
References
2
FWCI
12.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of synthetic ovine corticotropin-releasing factor. Dose response of plasma adrenocorticotropin and cortisol. https://app.cochat.ai/papers/10.1172/jci110804
The paper
Orth, D. N., Jackson, R. V., DeCherney, G. S., DeBold, C. R., Alexander, A. N., Island, D. P., Rivier, J., Rivier, C., Spiess, J., & Vale, W. (1983). Effect of synthetic ovine corticotropin-releasing factor. Dose response of plasma adrenocorticotropin and cortisol. Journal of Clinical Investigation. https://doi.org/10.1172/jci110804

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.