CoChat

Metabolic studies of radioiodinated serum amyloid P component in normal subjects and patients with systemic amyloidosis.

Open access
Hawkins, P N, Wootton, R, Pepys, M B · 1990 · Journal of Clinical Investigation
Cited by 95

The DOI matches its Crossref record.

Abstract

125I-Serum amyloid P component (SAP), injected intravenously into 10 normal subjects, remained predominantly intravascular with mean (SD) T1/2 (half time) in plasma of 24.5 (5.9) h. The fractional catabolic rate of 68 (19)% of the plasma pool per day was more rapid than other reported human plasma proteins. All radioactivity was excreted in the urine by 14 d. In 16 patients with monoclonal gammopathy or chronic inflammatory diseases, but without amyloidosis, 125I-SAP metabolism was normal. However, among 45 patients with biopsy-proven systemic amyloidosis (25, amyloid A type; 20, amyloid L type), 125I-SAP was cleared from the plasma more rapidly, accumulated in the amyloid deposits, and persisted there. The T1/2 in amyloid, measured directly with 131I-SAP, was 24 d. Repeat studies after 6-18 mo were notably consistent in normals but changed significantly in amyloid patients, generally correlating with clinical signs of disease progression. Measurements of 125I-SAP turnover may thus be of value for diagnosis and monitoring of amyloidosis. Analysis of SAP metabolism in amyloidosis suggests that plasma SAP is in dynamic equilibrium with a very large amyloid pool, and in two autopsies the total mass of SAP in the amyloid deposits was 2,100 and 21,000 mg, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci114917

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hawkins, P. N., Wootton, R., & Pepys, M. B.
Venue
Journal of Clinical Investigation
Published
1990-12-01
Volume
86
Issue
6
Pages
1862-1869
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2059846562
Cited by
95
References
0
FWCI
1.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.