Entrainment of pulsatile insulin secretion by oscillatory glucose infusion.
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Ultradian "oscillations" or "pulses" of insulin secretion with periods around 120 min occur in man. It is not known whether glucose plays an active role in generating these oscillations, or if an intrapancreatic pacemaker generates oscillations in insulin secretion that entrain glucose passively. To determine if the frequency of pulses of insulin secretion could be modified by oscillatory glucose infusion, seven normal men were studied on three separate occasions. The first study involved a constant glucose infusion administered at a rate of 6 mg/kg per min for 28 h. During the two subsequent studies, the subjects received an oscillatory glucose infusion for 28 h with the same mean rate, an amplitude of 33% above and below the mean infusion rate, a sinusoidal waveshape and a period either 20% longer ("slow oscillatory infusion") or 20% shorter ("rapid oscillatory infusion") than the periodicity observed during constant glucose infusion. Samples for insulin, C-peptide, and glucose were drawn at 10-min intervals during the last 24 h of each study. Insulin secretion rates were calculated by deconvolution of C-peptide levels. During constant glucose infusion, the respective periods of oscillation of glucose and insulin secretion averaged 126 +/- 5 min and 118 +/- 3 min (mean +/- SEM). During the slow oscillatory infusion, the period of infusion was 155 +/- 7 min and the periods of insulin secretion and glucose were, respectively, 155 +/- 7 min and 150 +/- 5 min. During rapid oscillatory infusion, the period of infusion was 103 +/- 5 min and the period of both insulin secretion and glucose was 105 +/- 5 min. Thus the periodicity of both insulin secretion and plasma glucose changed in parallel with the exogenous periodicity, indicating complete entrainment of the secretory oscillations. These results suggest that the ultradian oscillations of insulin secretion are caused by the feedback loop linking glucose and insulin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear Oscillations, Dynamical Systems, and Bifurcations of Vector Fields
Guckenheimer, J., & Holmes, P. (1983) · Applied Mathematical Sciences · doi:10.1007/978-1-4612-1140-2 · Cited by 16,144
Twenty-four-hour profiles and pulsatile patterns of insulin secretion in normal and obese subjects.
Polonsky, K. S., Given, B. D., & Van Cauter, E. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113339 · Cited by 763
Self-citationAbnormal patterns of insulin secretion in non-insulin-dependent diabetes mellitus.
Polonsky, K. S., Given, B. D., Hirsch, L. J., Tillil, H., Shapiro, E. T., Beebe, C., Frank, B. H., Galloway, J. A., & Van Cauter, E. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181903 · Cited by 567
Self-citationPrehepatic Insulin Production in Man: Kinetic Analysis Using Peripheral Connecting Peptide Behavior*
EATON, R. P., ALLEN, R. C., SCHADE, D. S., ERICKSON, K. M., & STANDEFER, J. (1980) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-51-3-520 · Cited by 363
Polonsky, K. S., Licinio-Paixao, J., Given, B. D., Pugh, W., Rue, P., Galloway, J., Karrison, T., & Frank, B. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112308 · Cited by 359
Self-citationInsulin transport across capillaries is rate limiting for insulin action in dogs.
Yang, Y. J., Hope, I. D., Ader, M., & Bergman, R. N. (1989) · Journal of Clinical Investigation · doi:10.1172/jci114339 · Cited by 303
SIMON, C., BRANDENBERGER, G., & FOLLENIUS, M. (1987) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-64-4-669 · Cited by 147
Cited by
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“Peakdetection methods provide information on pulse amplitude and location [161]–[164], while spectral/correlation analysis seeks to identify cycles in time series [165], [166].”
Ehrmann, D. A., Schneider, D. J., Sobel, B. E., Cavaghan, M. K., Imperial, J., Rosenfield, R. L., & Polonsky, K. S. (1997) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.82.7.4069 · Cited by 461
“respond to repetitive increases and decreases in glucose with parallel changes in insulin secretion) is affected by troglitazone, a 20% glucose solution was administered in an oscillatory pattern with a period of 144 min, as previously described (34, 35 ).”
MethodSelf-citationEhrmann, D. A., Sturis, J., Byrne, M. M., Karrison, T., Rosenfield, R. L., & Polonsky, K. S. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118064 · Cited by 426
Self-citationLambert, E. V., St Clair Gibson, A., & Noakes, T. D. (2005) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.011247 · Cited by 380
Ehrmann, D. A., Cavaghan, M. K., Imperial, J., Sturis, J., Rosenfield, R. L., & Polonsky, K. S. (1997) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.82.2.3722 · Cited by 336
Self-citationThe evolution of β‐cell dysfunction and insulin resistance in type 2 diabetes
Bergman, R. N., Finegood, D. T., & Kahn, S. E. (2002) · European Journal of Clinical Investigation · doi:10.1046/j.1365-2362.32.s3.5.x · Cited by 301
Pulsatile Insulin Secretion: Detection, Regulation, and Role in Diabetes
Pørksen, N., Hollingdal, M., Juhl, C., Butler, P., Veldhuis, J. D., & Schmitz, O. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s245 · Cited by 223
“Studies on entrainment of the ultradian insulin release pattern show that oscillatory glucose infusion may entrain oscillatory insulin release (52).”
BackgroundCavaghan, M. K., Ehrmann, D. A., Byrne, M. M., & Polonsky, K. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119562 · Cited by 216
Self-citationModeling the Insulin–Glucose Feedback System: The Significance of Pulsatile Insulin Secretion
TOLIĆ, I. M., MOSEKILDE, E., & STURIS, J. (2000) · Journal of Theoretical Biology · doi:10.1006/jtbi.2000.2180 · Cited by 212
“The model exhibits self-sustained oscillations when a constant glucose infusion is simulated for a large range of parameters (Sturis et al., 1991a).”
BackgroundMethodInfluentialSelf-citationMathematical modeling of the glucose–insulin system: A review
Palumbo, P., Ditlevsen, S., Bertuzzi, A., & De Gaetano, A. (2013) · Mathematical Biosciences · doi:10.1016/j.mbs.2013.05.006 · Cited by 184
“parameters identifying the distribution from which single-unit structural parameters are sampled, this population model is able to replicate both the ultradian and rapid pulsatile oscillatory regime, in the absence of exogenous periodic stimuli, like the clinical experiments detailed in [75,82].”
BackgroundEvidence for a circadian rhythm of insulin release from perifused rat pancreatic islets
Peschke, E., & Peschke, D. (1998) · Diabetologia · doi:10.1007/s001250051034 · Cited by 150
O'Meara, N. M., Sturis, J., Van Cauter, E., & Polonsky, K. S. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116560 · Cited by 132
“In addition, the periodicity of the insulin secretory oscillations can be entrained to the period of an oscillatory glucose infusion (9).”
BackgroundResultSelf-citationTemporal Profiles and Clinical Significance of Pulsatile Insulin Secretion
Polonsky, K. S., Sturis, J., & van Cauter, E. (1998) · Hormone Research in Paediatrics · doi:10.1159/000023168 · Cited by 50
“The purpose of this article is to review recent studies from our laboratory on the clinical and pathophysiological significance of these oscillations of secretion. Ultradian Oscillations of Insulin SecretionWe demonstrated that during the oscillatory infusion of exogenous glucose into normal humans the periodicity of…”
BackgroundSelf-citationKern, W. (1996) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.81.4.1541 · Cited by 38
Transitions between bursting modes in the integrated oscillator model for pancreatic β-cells
Marinelli, I., Vo, T., Gerardo-Giorda, L., & Bertram, R. (2018) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2018.06.017 · Cited by 28
Acute hyperglycemia alters the ability of the normal β-cell to sense and respond to glucose
Meyer, J., Sturis, J., Katschinski, M., Arnold, R., Göke, B., & Byrne, M. M. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00427.2001 · Cited by 25
“Each individual ISR profile from the oscillatory glucose infusion protocol was submitted to spectral analysis to investigate whether the oscillations were entrainable as previously reported (25).”
BackgroundMethodResultSelf-citation
Metadata
- Authors
- Sturis, J., Van Cauter, E., Blackman, J. D., & Polonsky, K. S.
- Venue
- Journal of Clinical Investigation
- Published
- 1991-02-01
- Volume
- 87
- Issue
- 2
- Pages
- 439-445
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2100737003
- Cited by
- 109
- References
- 7
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.