Role of leukotrienes in leukocyte adhesion following systemic administration of oxidatively modified human low density lipoprotein in hamsters.
Open accessThe DOI matches its Crossref record.
Abstract
In vitro studies indicate that oxidatively modified low density lipoprotein (oxLDL) promotes leukocyte adhesion to the vascu- lar endothelium, a constant feature of early atherogenesis.Using intravital fluorescence microscopy in the dorsal skinfold chamber model in awake Syrian golden hamsters, we studied whether (a) oxLDL elicits leukocyte/endothelium interaction in vivo, and whether (b) leukotrienes play a mediator role in this event.Leukocyte/endothelium interaction was assessed in the time course after intravenous injection of native human LDL (4 mg/kg body wt) and of oxLDL (7.5 gM Cu", 6 h, 370C) into control hamsters and into hamsters, pretreated with the selec- tive leukotriene biosynthesis inhibitor MK-886 (20 ;tmol/kg, i.v.).While no effect was seen after injection of native LDL, oxLDL elicited an immediate induction of leukocyte adhesion to the endothelium of arterioles and postcapillary venules.To- tal and differential leukocyte counts suggest that all leukocyte subsets were likewise affected by oxLDL with no specific pref- erence for monocytes.Stimulation of leukocyte adhesion was entirely prevented in inhibitor-treated animals, suggesting the important mediator role of leukotrienes in oxLDL-induced leu- kocyte/endothelium interaction.(J.Clin.Invest.1991.88:9- 14.) Key words: intravital fluorescence microscopy-microcir- culation * atherosclerosis -lipoxygenase Biochemicalproperties ofnativeLDL and oxLDL.a-and 'y-tocopherols were measured with HPLC according to the modified method of 1. Abbreviation used in this paper: oxLDL, oxidatively modified LDL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of lipid peroxidation and antioxidants in oxidative modification of LDL
Esterbauer, H., Gebicki, J., Puhl, H., & Jürgens, G. (1992) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(92)90181-f · Cited by 2,306
Acute impact of active and passive electronic cigarette smoking on serum cotinine and lung function
Flouris, A. D., Chorti, M. S., Poulianiti, K. P., Jamurtas, A. Z., Kostikas, K., Tzatzarakis, M. N., Wallace Hayes, A., Tsatsakis, A. M., & Koutedakis, Y. (2013) · Inhalation Toxicology · doi:10.3109/08958378.2012.758197 · Cited by 429
Sensitive detection of oxidatively modified low density lipoprotein using a monoclonal antibody.
Itabe, H., Yamamoto, H., Imanaka, T., Shimamura, K., Uchiyama, H., Kimura, J., Sanaka, T., Hata, Y., & Takano, T. (1996) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)37634-3 · Cited by 277
Frei, B., & Gaziano, J. M. (1993) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)35354-2 · Cited by 270
Keshavarzian, A., Sedghi, S., Kanofsky, J., List, T., Robinson, C., Ibrahim, C., & Winship, D. (1992) · Gastroenterology · doi:10.1016/0016-5085(92)91111-g · Cited by 262
Secondhand smoke as an acute threat for the cardiovascular system: a change in paradigm
Raupach, T., Schäfer, K., Konstantinides, S., & Andreas, S. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi601 · Cited by 251
“hamsters.(41) Clinical studies observed impaired endotheliumdependent vasorelaxation, the earliest sign of endothelial dysfunction, in smokers, and active as well as passive smoking inhibited endothelium-dependent vasodilatation to a similar extent.”
BackgroundScope and perspectives of intravital microscopy - bridge over from in vitro to in vivo
Menger, M. D., & Lehr, H.-A. (1993) · Immunology Today · doi:10.1016/0167-5699(93)90179-o · Cited by 174
Self-citationLehr, H. A., Frei, B., & Arfors, K. E. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.16.7688 · Cited by 167
Self-citationVitamin C blocks inflammatory platelet-activating factor mimetics created by cigarette smoking.
Lehr, H. A., Weyrich, A. S., Saetzler, R. K., Jurek, A., Arfors, K. E., Zimmerman, G. A., Prescott, S. M., & McIntyre, T. M. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119417 · Cited by 158
“Analysis of leukocyte interactions in the microcirculation (34) before smoke exposure and at the stated times after exposure was performed in four to six arterioles and venules (20–60 m m diameter) per observation window.”
MethodSelf-citationItabe, H. (2012) · Journal of Clinical Biochemistry and Nutrition · doi:10.3164/jcbn.11-00020r1 · Cited by 87
Metadata
- Authors
- Lehr, H. A., Hübner, C., Finckh, B., Angermüller, S., Nolte, D., Beisiegel, U., Kohlschütter, A., & Messmer, K.
- Venue
- Journal of Clinical Investigation
- Published
- 1991-07-01
- Volume
- 88
- Issue
- 1
- Pages
- 9-14
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2044005957
- Cited by
- 79
- References
- 0
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.