Surgical Implantation and Biocompatibility of Central Nervous System Auditory Prostheses
The DOI matches its Crossref record.
Abstract
As part of a program to determine the feasibility of a CNS auditory prosthesis, the tissue reaction to electrodes chronically implanted in the cochlear nucleus (CN) of the guinea pig was examined. Varied open operative approaches and microelectrode designs were utilized. Silicon substrate thin film and platinum-iridium wire electrodes, tethered and untethered, were placed successfully in different divisions of the CN. Implantation through a posterior suboccipital approach was most successful. Histologic examinations demonstrated a glial cell proliferation confined to the area of the electrode track that never exceeded 15 μm in width. No neuronal loss or significant effect on cell morphology was seen, and reactive cells were absent. Electrode migration was apparent in a minority of animal preparations. Although potential problems were identified, our findings lend support to the feasibility of implanting a neuroprosthesis in the CN and have helped to establish methods for future studies of chronic intranuclear stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
“Both titanium and ceramic (Chouard and Pialoux, 1995) and platinum–iridium wire (Niparko et al., 1989) have been shown as biocompatible in cochlear implants.”
BackgroundSurface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
Self-citationIn vivo studies of polypyrrole/peptide coated neural probes
Cui, X. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00415-5 · Cited by 505
Kim, D. ‐., Richardson‐Burns, S. M., Hendricks, J. L., Sequera, C., & Martin, D. C. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200500594 · Cited by 299
Conducting polymers grown in hydrogel scaffolds coated on neural prosthetic devices
Kim, D., Abidian, M., & Martin, D. C. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30124 · Cited by 289
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282
“Polytrode materials are biocompatible (Niparko et al. 1989) and are suitable for chronic implantation (Hetke et al. 1994; Hoogerwerf and Wise 1994; Mensinger et al. 2000; Rousche and Normann 1998; Vetter et al. 2004), and cortical microstimulation (Anderson et al. 1989; Rousche and Normann 1999;…”
BackgroundSilicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationA micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144
Martins, N. R. B., Angelica, A., Chakravarthy, K., Svidinenko, Y., Boehm, F. J., Opris, I., Lebedev, M. A., Swan, M., Garan, S. A., Rosenfeld, J. V., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00112 · Cited by 91
Prosthetic Stimulation of the Auditory System with Intraneural Electrodes
Arts, H. A., Jones, D. A., & Anderson, D. J. (2003) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894031120s905 · Cited by 22
Self-citation
Metadata
- Authors
- Niparko, J. K., Altschuler, R. A., Wiler, J. A., Xue, X., & Anderson, D. J.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 1989-12
- Volume
- 98
- Issue
- 12
- Pages
- 965-970
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2018043076
- Cited by
- 62
- References
- 0
- FWCI
- 0.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.