A micromachined silicon sieve electrode for nerve regeneration applications
Open accessAbstract
A micromachined silicon sieve electrode has been developed and fabricated to record from and stimulate axons/fibers of the peripheral nervous system by utilizing the nerve regeneration principle. The electrode consists of a 15-microns-thick silicon support rim, a 4-microns-thick diaphragm containing different size holes to allow nerve regeneration, thin-film iridium recording/stimulating sites, and an integrated silicon ribbon cable, all fabricated using boron etch-step and silicon micromachining techniques. The thin diaphragm is patterned using reactive ion etching to obtain different size holes with diameters as small as 1 micron and center-center spacings as small as 10 microns. The holes are surrounded by 100-200 microns 2 anodized iridium oxide sites, which can be used for both recording and stimulation. These sites have impedances of less than 100 k omega @ 1 kHz and charge delivery capacities in the 4-6 mC/cm2 range. The fabrication process is single-sided, has high yield, requires only five masks, and is compatible with integrated multilead silicon ribbon cables. The electrodes were implanted between the cut ends of peripheral taste fibers of rats (glossopharyngeal nerve), and axons functionally regenerated through holes, responding to chemical, mechanical, and thermal stimuli.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The degree of successful regeneration through regenerative electrodes greatly differs between in vivo experiments.
“the degree of successful regeneration through the electrodes greatly differs between in vivo experiments (Akin et al., 1994; Srinivasan et al., 2015).”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Akin et al., 1994
Cites
A high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 303 · see citing works
Self-citationGesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287156 · Cited by 302 · see citing works
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229 · see citing works
Self-citationActivated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 228 · see citing works
Beebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 220 · see citing works
Microelectrode methods for intracellular recording and ionophoresis
Purves, R. D. (1981) · Academic Press eBooks · Cited by 207 · see citing works
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · see citing works
An implantable CMOS circuit interface for multiplexed microelectrode recording arrays
Ji, J., & Wise, K. D. (1992) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.121568 · Cited by 173 · see citing works
Regeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 164 · see citing works
Mannard, A., Stein, R. B., & Charles, D. (1974) · Science · doi:10.1126/science.183.4124.547 · Cited by 85 · see citing works
Surgical Implantation and Biocompatibility of Central Nervous System Auditory Prostheses
Niparko, J. K., Altschuler, R. A., Wiler, J. A., Xue, X., & Anderson, D. J. (1989) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948909801209 · Cited by 62 · see citing works
Design, Fabrication, and In Vivo Behavior of Chronic Recording Intracortical Microelectrodes
Salcman, M., & Bak, M. J. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324189 · Cited by 60 · see citing works
Loeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46 · see citing works
Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays
Bradley, R. M., Smoke, R. H., Akın, T., & Najafi, K. (1992) · Brain Research · doi:10.1016/0006-8993(92)91031-9 · Cited by 44 · see citing works
Self-citationAuditory Brainstem Prosthesis: Biocompatability of Stimulation
Niparko, J. K., Altschuler, R. A., Evans, D. A., Xue, X., Farraye, J., & Anderson, D. J. (1989) · Otolaryngology · doi:10.1177/019459988910100308 · Cited by 23 · see citing works
Flexible silicon interconnects for microelectromechanical systems
Hetke, J. F., Najafi, K., & Wise, K. D. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148994 · Cited by 20 · see citing works
Self-citationA micromachined silicon sieve electrode for nerve regeneration applications
Akın, T., & Najafi, K. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148818 · Cited by 19 · see citing works
Self-citationRegeneration microelectrode arrays for direct interface to nerves
Kovacs, G. T. A. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148814 · Cited by 12 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · see citing works
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231 · see citing works
Ceramic-Based Multisite Microelectrodes for Electrochemical Recordings
Burmeister, J. J., Moxon, K., & Gerhardt, G. A. (2000) · Analytical Chemistry · doi:10.1021/ac9907991 · Cited by 196 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Stieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125 · see citing works
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96 · see citing works
Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics
Rijnbeek, E. H., Eleveld, N., & Olthuis, W. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00350 · Cited by 91 · see citing works
“, 2000) and the degree of successful regeneration through the electrodes greatly differs between in vivo experiments (Akin et al., 1994; Srinivasan et al., 2015).”
BackgroundFabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93 · see citing works
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76 · see citing works
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73 · see citing works
Regenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67 · see citing works
A wafer-scale etching technique for high aspect ratio implantable MEMS structures
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.011 · Cited by 71 · see citing works
Chronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70 · see citing works
Lago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68 · see citing works
Long term chronic recordings from peripheral sensory fibers using a sieve electrode array
Bradley, R. M., Cao, X., Akin, T., & Najafi, K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02225-5 · Cited by 69 · see citing works
Self-citationMotor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63 · see citing works
Ceballos, D., Valero‐Cabré, A., Valderrama, E., Schüttler, M., Stieglitz, T., & Navarro, X. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10099 · Cited by 61 · see citing works
Neural interfaces for regenerated nerve stimulation and recording
Dario, P., Garzella, P., Toro, M., Micera, S., Alavi, M., Meyer, U., Valderrama, E., Sebatiani, L., Ghelarducci, B., Mazzoni, C., et al. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736149 · Cited by 58 · see citing works
Regenerated sciatic nerve axons stimulated through a chronically implanted macro-sieve electrode
MacEwan, M. R., Zellmer, E. R., Wheeler, J. J., Burton, H., & Moran, D. W. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00557 · Cited by 48 · see citing works
Material considerations for peripheral nerve interfacing
Kim, Y.-T., & Romero-Ortega, M. I. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.99 · Cited by 47 · see citing works
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46 · see citing works
Gore, R. K., Choi, Y., Bellamkonda, R., & English, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016017 · Cited by 26 · see citing works
- Authors
- Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M.
- Affiliations
- University of Michigan (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1994-04
- Volume
- 41
- Issue
- 4
- Pages
- 305-313
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2020307886
- Cited by
- 144
- References
- 18
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 3 · 2018: 4 · 2017: 4 · 2016: 3 · 2015: 6 · 2014: 3 · 2013: 2 · 2012: 5
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- OpenMETU (Middle East Technical University) (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute on Deafness and Other Communication Disorders (DC00059)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- nerve regeneration, peripheral nerve stimulation, peripheral nerve recording, iridium oxide, thin film electrodes, silicon micromachining, reactive ion etching, glossopharyngeal nerve, axon regeneration, implanted electrodes
- MeSH terms
- Animals, Electrodes, Implanted, Equipment Design, Glossopharyngeal Nerve, Materials Testing, Microelectrodes, Nerve Regeneration, Silicon, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review