Chemometrics for Raman Spectroscopy Harmonization
The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
Raman spectroscopy is used in a wide variety of fields, and in a plethora of different configurations. Raman spectra of simple analytes can often be analyzed using univariate approaches and interpreted in a straightforward manner. For more complex spetral data such as time series or line profiles (1D), Raman maps (2D), or even volumes (3D), multivariate data analysis (MVDA) becomes a requirement. Even though there are some existing standards for creation, implementation, and validation of methods and models employed in industry and academics, further research and development in the field must contribute to their improvement. This review will cover, in broad terms, existing techniques as well as new developments for MVDA for Raman spectroscopic data, and in particular the use associated with instrumentation and data calibration. Chemometric models are often generated via fusion of analytical data from different sources, which enhances model discrimination and prediction abilities as compared to models derived from a single data source. For Raman spectroscopy, raw or unprocessed data is rarely ever used. Instead, spectra are usually corrected and manipulated, 1 often by case-specific rather than universal methods. Calibration models can be used to characterize qualitatively and/or quantitatively samples measured with the same instrumentation that was used to create the model. However, regular validation is required to ensure that aging or incorrect maintenance of the instrument does not alter the model’s predictions, particularly when applied in regulated fields such as pharmaceuticals. Furthermore, a model transfer may be required for different reasons, such as replacement or significant repair of the instrumentation. Modeling can also be used to consistently harmonize Raman spectroscopic data across several instrumental designs, accounting for variations in the resulting spectrum induced by different components. Data for Raman harmonization models should be processed in a protocolled manner, and the original data accessible to allow for model reconstruction or transfer when new data is added. Important processing steps will be the calibration of the spectral axes and instrument dependent effects, such as spectral resolution. In addition, data fusion and model transfer are essential for allowing new instrumentation to build on existing models to harmonize their own data. Ideally, an open access database would be created and maintained, for the purpose of allowing for continued harmonization of new Raman instruments using an outlined and accepted protocol.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, there is little concrete description of how quantitation is affected by one’s choice of numerical unmixing algorithm and the nature of the spectral bands being scrutinized, and little has been done to create consistent standard samples to interrogate quantitation robustness.21,22”
From Assessment of unmixing approaches for the quantitation of SERS nanoparticles in highly multiplexed spectral images (2024) · cites this paper as [21]
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
LOF: identifying density-based local outliers
Breunig, M. M., Kriegel, H.-P., Ng, R. T., & Sander, J. (2000) · ACM SIGMOD Record · doi:10.1145/335191.335388 · Cited by 5,207
Handbook of Vibrational Spectroscopy
(2001) · Wiley eBooks · doi:10.1002/0470027320 · Cited by 2,986
Model Selection and Multimodel Inference
(2004) · Springer eBooks · doi:10.1007/b97636 · Cited by 2,582
An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements
Cohen, E. R. (1998) · Measurement Science and Technology · doi:10.1088/0957-0233/9/6/022 · Cited by 1,499
Sternberg (1983) · Computer · doi:10.1109/mc.1983.1654163 · Cited by 930 · cited 1×
“4),(27) advanced penalized least squares approaches,(28) sensitive nonlinear iterative peak (SNIP) algorithms,(29) Goldinec,(30) spline-fitting methods, such as morphology-based cubic p-spline fitting(31) or b-spline fitting, piecewise polynomial fitting,(32) wavelet feature points,(33) convolutional neural networks,(…”
MethodThe Cambridge Dictionary of Statistics: Fourth Edition
Everitt, B. S., & Skrondal, A. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511779633 · Cited by 820
Data fusion methodologies for food and beverage authentication and quality assessment – A review
Borràs, E., Ferré, J., Boqué, R., Mestres, M., Aceña, L., & Busto, O. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.04.042 · Cited by 743
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Research works printed but not linked: 19
- National Institute of Standards and Technology (NIST), 2019, SRM 2242a. Relative Intensity Correction Standard for Raman Spectroscopy: 532 nm Excitation
- Ozog D., 2017, Signal Processing
- Beleites C., Sergo V. “Chemometric Analysis of Spectroscopic Data in R: HyperSpec”. Poster presented at: 13th European Conference on the Spectroscopy of Biological Molecules (ECSBM). Palermo, Italy; 28 August–2 September 2009. https://hyperspec.r-forge.r-project.org/blob/Beleites2009.pdf [accessed Mar 25 2022].
- Demšar J., 2013, J. Machine Learning Res, 14, 2349
- Barton B., Zou M., Geertz G., Metsch-Zillingen E., Brüll R. “Raman Imaging of Additives in Polymers: Multivariate Decomposition of 3D Maps and Super-Resolution Imaging”. Presented at: International Conference for Chemical Characterization and Imaging. Ulm, Germany; 23–25 September 2019.
- Demšar J., 2013, J. Mach. Learn. Res, 14, 2349
- Powers D.M.W. “What the F-Measure Doesn’t Measure: Features, Flaws, Fallacies and Fixes”. ArXiv. 2015. https://arxiv.org/ftp/arxiv/papers/1503/1503.06410.pdf [accessed Mar 25 2022].
- National Institute of Standards and Technology (NIST), 2022, SRM 2241 Relative Intensity Correction Standard for Raman Spectroscopy: 785 nm Excitation
- 10.1520/E1654-94R13.2 · doi:10.1520/e1654-94r13.2
- 10.1520/E1683-02R14E01.2 · doi:10.1520/e1683-02r14e01.2
- ASTM International, 2014, ASTM E1840–96 Standard Guide for Raman Shift Standards for Spectrometer Calibration
- ASTM International, 2014, ASTM E2529–06 Standard Guide for Testing the Resolution of a Raman Spectrometer
- ASTM International, 2013, ASTM E2911–13 Standard Guide for Relative Intensity Correction of Raman Spectrometers
- ASTM International, 2017, ASTM E2617–17 Standard Practice for Validation of Empirically Derived Multivariate Calibrations
- 10.31003/USPNF_M8188_02_01 · DOI
- United States Pharmacopeial Convention, 2020, <1039> Chemometrics
- ASTM International, 2002, ASTM E456–02 Standard Terminology Relating to Quality and Statistics
- ASTM International, 2021, ASTM E178–21 Standard Practice for Dealing with Outlying Observations
- 10.1039/c1an15636e · DOI
Cited by
Artifacts and Anomalies in Raman Spectroscopy: A Review on Origins and Correction Procedures
Vulchi, R. T., Morgunov, V., Junjuri, R., & Bocklitz, T. W. (2024) · Molecules · doi:10.3390/molecules29194748 · Cited by 124
RamanSPy: An Open-Source Python Package for Integrative Raman Spectroscopy Data Analysis
Georgiev, D., Pedersen, S. V., Xie, R., Fernández-Galiana, Á., Stevens, M. M., & Barahona, M. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c00383 · Cited by 108
Review of Existing Standards, Guides, and Practices for Raman Spectroscopy
Ntziouni, A., Thomson, J., Xiarchos, I., Li, X., Bañares, M. A., Charitidis, C., Portela, R., & Lozano Diz, E. (2022) · Applied Spectroscopy · doi:10.1177/00037028221090988 · Cited by 73
Self-citationTang, J., Yuan, Q., Zhang, L., Marshall, B. J., Tay, C. Y., & Wang, L. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118135 · Cited by 74
Xuesong, H., Chen, P., Li, J., Xu, Y., Liu, D., & Chu, X. (2023) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2023.2204946 · Cited by 58
Flanagan, A. R., Dalal, D., & Glavin, F. G. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00815 · Cited by 66
Xie, M., Zhu, Y., Li, Z., Yan, Y., Liu, Y., Wu, W., Zhang, T., Li, Z., & Wang, H. (2023) · Talanta · doi:10.1016/j.talanta.2023.125281 · Cited by 50
Artificial Intelligence-Powered Raman Spectroscopy through Open Science and FAIR Principles
Coca-López, N., Alcolea-Rodriguez, V., Bañares, M. Á., Brockhauser, S., Gorenflot, J., Henderson, A., Hildebrandt, R., Jeliazkova, N., Kochev, N. T., Diz, E. L., et al. (2025) · ACS Nano · doi:10.1021/acsnano.5c09165 · Cited by 59
Self-citationAn intuitive approach for spike removal in Raman spectra based on peaks’ prominence and width
Coca-López, N. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342312 · Cited by 30
Sun, J., He, D., & You, Y. (2025) · Food Bioscience · doi:10.1016/j.fbio.2025.106281 · Cited by 25
Machine Learning of Raman Spectroscopic Data: Comparison of Different Validation Strategies
Lilek, D., Zimmermann, D., Steininger, L., Musso, M. E., Wilts, B. D., Gamsjaeger, S., Hermann, D., Wiesner, C., Grünfelder, A., Herbinger, B., et al. (2025) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6842 · Cited by 27
Klingenberg, P., Brüll, R., Fell, T., Barton, B., Soll, M., Emans, T., Bakker, F., & Geertz, G. (2024) · Waste Management · doi:10.1016/j.wasman.2024.02.020 · Cited by 19
Self-citationRen, Y. N., Zheng, Y., Wang, X., Qu, S., Sun, L., Song, C., Ding, J. J., Ji, Y., Wang, G., Zhu, P., et al. (2024) · Frontiers in Microbiology · doi:10.3389/fmicb.2024.1361180 · Cited by 17
“In recent years, researchers have begun to focus on the interpretability of machine learning models, which can significantly improve prediction accuracy and are more credible (Guo et al., 2021; Barton et al., 2022).”
BackgroundRADAR: Raman Spectral Analysis Using Deep Learning for Artifact Removal
Sjöberg, J., Siminea, N., Păun, A., Lita, A., Larion, M., & Petre, I. (2025) · Advanced Optical Materials · doi:10.1002/adom.202500736 · Cited by 16
Illuminating the Tiny World: A Navigation Guide for Proper Raman Studies on Microorganisms
Frempong, S. B., Salbreiter, M., Mostafapour, S., Pistiki, A. C., Bocklitz, T. W., Rösch, P., & Popp, J. (2024) · Molecules · doi:10.3390/molecules29051077 · Cited by 13
“In the next step, a normalization [286] is executed to ensure that spectra obtained on different measurement days and conditions can be effectively compared and analyzed.”
Bai, Y., & Zhang, H. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e37479 · Cited by 12
Renata, S., Verma, N., & Peddinti, R. K. (2024) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2024.125631 · Cited by 14
Open Source for Raman Spectroscopy Data Harmonization
Georgiev, G., Coca-López, N., Lellinger, D., Iliev, L., Marinov, E. I., Tsoneva, S. H., Kochev, N. T., Bañares, M. Á., Portela, R., & Jeliazkova, N. (2025) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6789 · Cited by 15
Self-citationMonaghan, J. F., Byrne, H. J., Lyng, F. M., & Meade, A. D. (2024) · Radiation · doi:10.3390/radiation4030022 · Cited by 14
Lellinger, D., Thomson, J., Coca-López, N., Ntziouni, A., Nikoloudakis, N., Fernández-Álvarez, M., Jeliazkova, N., Bañares, M. Á., Portela, R., & Diz, E. L. (2025) · Applied Spectroscopy · doi:10.1177/00037028251330654 · Cited by 14
Self-citationSchini, A., Canditiis, B. D., Sanchez, C., Pierrelée, M., Voltz, K., & Jourdainne, L. (2023) · Biotechnology Journal · doi:10.1002/biot.202300028 · Cited by 10
“[19] Theprincipleofcapacitancemeasurementisbasedontheapproach thatcellsareconsideredtobedielectricentities,ascellmembranesare non-conductive and isolative.”
Eshbekova, N., Sowndarya, A., Thangadurai, T. D., & Lee, Y. (2024) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2024.2355193 · Cited by 13
Konstantopoulos, G., Charitidis, C. A., Bañares, M. Á., Portela, R., Zangenberg, N., Capria, E., Sebastiani, M., Goldbeck, G., Koumoulos, E. P., Boskovic, B. O., et al. (2023) · Materials Today Communications · doi:10.1016/j.mtcomm.2023.106607 · Cited by 9
Self-citationNew Protocol for Twinning of Raman Devices Toward a Raman Intensity Harmonization
Fernández-Álvarez, M., Moure, A., Reinosa, J. J., Diz, E. L., & Fernández, J. F. (2024) · Applied Spectroscopy · doi:10.1177/00037028241260377 · Cited by 12
“…as the quantum ef fi ciency of the detector, laser amplitude and mode, grating ef fi ciency, and the re fl ection and transmission ef fi ciencies of optical components such as objectives, gratings, mirrors, and optics, 20 – 22 which affects the arbitrary intensity counts given by each Raman instrument.”
BackgroundA machine learning approach for the automated classification of bulk sp2 and sp3 carbon materials
daFonseca, B. G., Thind, S. S., Booth, I., & Brolo, A. G. (2023) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6608 · Cited by 8
Czaja, A., Awad, S., Eremina, O. E., Fernando, A., & Zavaleta, C. (2024) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6653 · Cited by 8
Gao, Y., & Xu, M. (2024) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2024.2407112 · Cited by 7
“[104] Chemometric techniques involve spectral processing and statistical analysis of data required to find the spectral differences that are most useful for differentiation between samples, e.g. the differentiation between different cell types.”
Fadzillah, N. A., Elgharbawy, A. A. M., Jamaluddin, M. A., Tukiran, N. A., Windarsih, A., Rohman, A., Sukri, S. J. M., Muhammad, N. W. F., & Hamid, A. H. (2025) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2025.103785 · Cited by 9
Structure–spectrum relationship in the calculated Raman spectra of silicates
Bagheri, M., & Komsa, H. (2024) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6686 · Cited by 6
Fernández-Álvarez, M., Marín-Cortés, S., Moure, A., & Fernández, J. F. (2025) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2025.178861 · Cited by 6
Cell Culture Media and Raman Spectra Preprocessing Procedures Impact Glucose Chemometrics
Pavurala, N., Madhavarao, C. N., Lee, J., Das, J., Ashraf, M., & O’Connor, T. F. (2025) · Journal of Chemometrics · doi:10.1002/cem.70005 · Cited by 8
Vyas, B., Halámková, L., & Lednev, I. K. (2024) · The Analyst · doi:10.1039/d4an00938j · Cited by 7
Nair, S., Coca-López, N., Madubuko, N., Portela, R., Taccardi, N., Haumann, M., Bañares, M. Á., & Wasserscheid, P. (2025) · ChemCatChem · doi:10.1002/cctc.202500176 · Cited by 6
Self-citationGalli, R., & Uckermann, O. (2025) · Micron · doi:10.1016/j.micron.2025.103800 · Cited by 5
Coloma, L., Aramendia, J., Amigo, J. M., Población, I., Alberquilla, F., Gorla, G., Huidobro, J., Torre-Fdez, I., Arana, G., & Madariaga, J. M. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126194 · Cited by 5
Yao, Y., Li, M., Zhang, L., Meng, J., Liu, L., Li, W., & Zhang, J. (2026) · Analytical Methods · doi:10.1039/d5ay01692d · Cited by 5
Spectral harmonization of Raman data for reliable anti-counterfeiting analysis
Fernández-Álvarez, M., Moure, A., Rabasco, P., Gómez, E., García-Juez, V., & Fernández, J. F. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.115010 · Cited by 5
Hassan, M., Islam, M. S. B., Mahmud, S., Elgamal, M., Sumon, M. S. I., Hssain, A. A., Ibrahim, E., Kumar, A., Zhao, Y., Kashem, S. B. A., et al. (2025) · Talanta · doi:10.1016/j.talanta.2025.129332 · Cited by 5
Muñoz-Bolaños, J. D., Shaik, T. A., Miernik, A. J., Popp, J., & Krafft, C. (2024) · Applied Sciences · doi:10.3390/app14114726 · Cited by 4
RamanSPy: An open-source Python package for integrative Raman spectroscopy data analysisPreprint
Georgiev, D., Pedersen, S. V., Xie, R., Galiana, A. F., Stevens, M. M., & Barahona, M. (2023) · ChemRxiv · doi:10.26434/chemrxiv-2023-m3xlm · Cited by 3
Pierre, K., McCann, U. G., Razavi, S. M. S., Patel, A. B., Acevedo, A., Cerillo, J., Raviprasad, A. G., Zhou, J., Rashdan, D., & Lucke-Wold, B. P. (2024) · The Egyptian Journal of Neurosurgery : the official publication of the Egyptian Society of Neurological Surgeons/Egyptian journal of neurosurgery · doi:10.1186/s41984-024-00292-7 · Cited by 3
“Tools like Raman spectroscopy can be quantitatively validated once set to specific calibrations [30].”
BackgroundImpact of Beam Profile on Raman Spectroscopy Measurements
Tsikritsis, D., Coca-López, N., Papadakis, V. M., Paton, K. R., Portela, R., Kenanakis, G., Bañares, M. Á., & Belsey, N. A. (2025) · Journal of Raman Spectroscopy · doi:10.1002/jrs.70034 · Cited by 4
Self-citationWong, J. X., Ouyang, J., Lapointe, F., Mirka, B., & Finnie, P. (2024) · Applied Spectroscopy Practica · doi:10.1177/27551857241281755 · Cited by 2
“The need for standardization in Raman spectroscopy 16 and of multivariate analysis in Raman spectroscopic chemical analysis in particular 17 is widely recognized.”
Brands, R., Bartsch, J., & Thommes, M. (2024) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2024.10.044 · Cited by 2
Ozawa, K., Itakura, T., & Ono, T. (2024) · Applied Spectroscopy · doi:10.1177/00037028241248200 · Cited by 2
“Weighted-averaging-based methods apply convolution with various kernels [9, 10].”
Spike detection algorithms for Raman spectroscopy: a comparative study
Georgiev, G., Portela, R., Bañares, M. Á., & Coca-López, N. (2024) · Data Science for Photonics and Biophotonics · doi:10.1117/12.3023770 · Cited by 2
“1,2 Spikes are typically generated by cosmic particles impinging on the detector during spectrum acquisition.”
Self-citationAtomistic insights on the elasticity and Raman spectra of C‐S‐H from quantum‐mechanical simulations
Maul, J., Mitoli, D., Erba, A., & Dutra, R. P. S. (2025) · Journal of the American Ceramic Society · doi:10.1111/jace.70399 · Cited by 2
DMSO: a potential wavenumber calibrator of a coupled optical fiber Raman spectrograph
Salinas-Luna, J., Mentado-Morales, J., Ximello-Hernández, A., & Castro, J. (2025) · Physica Scripta · doi:10.1088/1402-4896/ae296a · Cited by 1
Spectroscopic Methods of Edible Flower Authentication and Quality Control for Food Applications
Benimana, F., Kucha, C. T., Roy, A., & Mohan, A. (2025) · eFood · doi:10.1002/efd2.70114 · Cited by 1
de Oliveira, A. C., Lessard, M., & Ghislain, T. (2026) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2026.108858 · Cited by 1
Kim, N., Dong, E., Tschudi, K., & Camperi, J. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1800423 · Cited by 1
Han, S.-H., Park, J., Kwang-Bae, L., Park, C.-H., & Lee, D.-Y. (2026) · Bioresources and Bioprocessing · doi:10.1186/s40643-026-01105-5 · Cited by 1
“…context, future work will focus on integrating the optimized variable-specific preprocessing strategies identified here with formal model transfer techniques (Barton et al. 2022) to further enhance long-term robustness and scalability of Raman-based monitoring models across bioprocess platforms.”
Coca-López, N., Rodriguez, F., Lundegaard, L. F., li, X., Diz, E. L., Rasmussen, S. B., Tielens, F., Calatayud, M., Bañares, M. Á., Portela, R., et al. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.177865 · Cited by 1
Self-citationA re-examination of thin-film silicon’s Raman spectrum
Cheung, S. H., Schmidt, K. J., Baribeau, J. ‐., Lockwood, D. J., & O’Leary, S. K. (2024) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-024-12616-2 · Cited by 1
“Such an approach to peak-fitting, however, may lead to results that are discordant with the underlying physics, as embod-ied in the one-phonon density-of-states [78].”
Hashimoto, K., YONEZAWA, S., Haruki, T., Koizumi, K., Oshima, Y., Kitajima, I., Sato, H., & Saito, S. (2024) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2024.151167 · Cited by 1
Virus Inactivation by Catalytic Air Converter Filters: The Role of Coating Methods
Gómez-López, A., Serrano-Lotina, A., Vázquez-Calvo, Á., Coca-López, N., Llanos, P., García-Castey, T., Alcamı́, A., & Bañares, M. Á. (2025) · ACS Omega · doi:10.1021/acsomega.5c05992 · Cited by 1
RamanSPy : An open-source Python package for integrative Raman spectroscopy data analysisPreprint
Georgiev, D., Pedersen, S. V., Xie, R., Fernández-Galiana, Á., Stevens, M. M., & Barahona, M. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.07.05.547761 · Cited by 2
RamanSPy: An open-source Python package for integrative Raman spectroscopy data analysis
Georgiev, D., Pedersen, S. V., Xie, R., Fernández-Galiana, Á., Stevens, M. M., & Barahona, M. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2307.13650 · Cited by 4
Kinetics of the Scavenging Reactions of Hydrogen Sulfide with MEA-triazine
Logrono, I. A. R. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau561830543
Iterative Regression of Corrective Baselines (IRCB): A New Model for Quantitative Spectroscopy
Glace, M., Moazeni‐Pourasil, R. S., Cook, D. W., & Roper, T. D. (2024) · Journal of Chemical Information and Modeling · doi:10.1021/acs.jcim.4c00359
Metawea, A., Albadarin, A. B., Jović, O., Aramouni, N. A. K., Walker, G., & Mouras, R. (2025) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2025.113558
Comparison of different Raman spectrometer models in the quantification of blood serum analytes
Giana, H. E., Souza, L. O., & Silveira, L. (2025) · Lasers in Medical Science · doi:10.1007/s10103-025-04413-y
Hassan, M. I., Islam, M. S. B., Mahmud, S., Elgamal, M., Sumon, M. S. I., Hssain, A. A., Ibrahim, E., Kumar, A., Zhao, Y., Chowdhury, M. E. H., et al. (2025) · Research Square · doi:10.21203/rs.3.rs-7431074/v1
Convolutional Autoencoder for Automated Pre-Processing of Tumor Cell and Tissue Raman Spectra
Fuentes, A. M., Milligan, K., Wiebe, M., Lum, J. J., Brolo, A. G., Andrews, J. L., & Jirasek, A. I. (2026) · Applied Spectroscopy · doi:10.1177/00037028261422275
“26 In biomedical specimens, baseline arises primarily from the sample substrate and biological fl uorescence.”
InfluentialAssaad, A. A. (2023) · theses.fr (ABES) · doi:10.70675/d21af1f0z83eaz4ec6z8b74z6815eb479999 · Cited by 1
Raman spectroscopy in renal analysis: Technologies, applications, and advancements
Zhang, X., Zhou, Y., Hou, X. S., & Xia, D. (2026) · Talanta · doi:10.1016/j.talanta.2026.129860 · Cited by 2
Liu, Z., Li, J., Lou, J., Bi, Z., Shen, Q., & Zhao, K. (2026) · Analytica Chimica Acta · doi:10.1016/j.aca.2026.345577
Peralta, P., Ortega‐Toro, R., & Fernández, J. A. H. (2026) · Analytica—A Journal of Analytical Chemistry and Chemical Analysis · doi:10.3390/analytica7020041
“By maintaining near-perfect linearity up to nearly 0.8 M, our method covers a concentration window that is outside the optimal operating range of most ultra-sensitive electrochemical sensors, which often saturate or lose selectivity at molar concentrations [40].”
InfluentialGonzález-Galeana, C., Rivas-Vela, C. I., Castañeda-Salazar, A., Portilla-Dominguez, K., & Bernal-Alvarez, L. R. (2026) · Expert Systems with Applications · doi:10.1016/j.eswa.2026.133471
kumar, S. S., Ahamed, J. I., Presley, S. I. D., Prabakaran, R., & Udayappan, V. (2026) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2026.147115
Li, Y., Fang, Z., Zhou, R.-G., Wan, X., Ren, P., & Xin, Y. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.128416
Martins, P. G. M., da Silva, D. R., Gonçalves, V. P., Pasa, V. M. D., & Almeida, M. R. (2026) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2026.105834
Sequential Learning of Raman Signatures From Attenuated Spectral Inputs Using Deep Neural Networks
Yadav, H., Yadav, V., & Siddhanta, S. (2026) · Advanced Theory and Simulations · doi:10.1002/adts.70495
“D sequential data, allowing the application of neural networks used in time series analysis [ 58 ].”
Palomo, J. A. P., López, J., & Fernández, J. A. H. (2026) · Molecules · doi:10.3390/molecules31152667
“The same preprocessing parameters were applied to all spectra to reduce instrumental noise without producing detectable changes in band position, width, or overall spectral profile [34,35].”
Bashir, A., Ali, A., Naman, A., Alsharif, K. F., Alzahrani, F. M., Alzahrani, K. J., Mehmood, N., & Kim, M. (2026) · Analytical Letters · doi:10.1080/00032719.2026.2716106
Guo, Y., Schiemer, R., Wang, G., Studts, J., & Hubbuch, J. J. (2026) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2026.103960
Trigueros, E., Magnaghi, L. R., Vita, L. D., Doveri, L., Sturini, M., Milanese, C., & Biesuz, R. (2026) · ChemistryOpen · doi:10.1002/open.70300
“…prior to PCA appli cation includes Raman shift range selection (1800–580 cm − 1 ), Savitsky‐Golay filtering (polynomial degree 3, window size 15), and normalization by Standard Normal Variate (SNV), following a well‐established procedure for Raman data multivariate treat ment [28–31].”
Tang, G., & Jiang, H. (2026) · Analytical Letters · doi:10.1080/00032719.2026.2743181
Alcolea-Rodriguez, V., Bresci, A., Mühlig, A., Agrimi, C., Morasso, C., Polli, D., Guntinas‐Lichius, O., & Vanna, R. (2026) · Chemical Society Reviews · doi:10.1039/d6cs00966b
Metadata
- Authors
- Barton, B., Thomson, J., Lozano Diz, E., & Portela, R.
- Affiliations
- Fraunhofer Institute for Structural Durability and System Reliability (DE)
- ELODIZ Ltd, High Wycombe, UK
- Consejo Superior de Investigaciones Científicas (ES)
- Corresponding author
- Portela, Raquel
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2022-05-27
- Volume
- 76
- Issue
- 9
- Pages
- 1021-1041
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W4281956143
- Cited by
- 79
- References
- 87
- Citations by year
- 2026: 20 · 2025: 24 · 2024: 24 · 2023: 10 · 2022: 1
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Applied Spectroscopy (publishedVersion)
- PubMed (publishedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Funders
- European Commission (952921)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Mathematics › Statistics and Probability › Advanced Statistical Methods and Models
- Keywords
- Raman spectroscopy, multivariate analysis, chemometrics, data harmonization, calibration models, model transfer, data fusion, spectral calibration, spectral resolution, model validation, model reconstruction, pharmaceutical analysis
- MeSH terms
- Chemometrics, Calibration, Pharmaceutical Preparations, Spectrum Analysis, Raman
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.