Chemometrics for Raman Spectroscopy Harmonization
The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
Raman spectroscopy is used in a wide variety of fields, and in a plethora of different configurations. Raman spectra of simple analytes can often be analyzed using univariate approaches and interpreted in a straightforward manner. For more complex spetral data such as time series or line profiles (1D), Raman maps (2D), or even volumes (3D), multivariate data analysis (MVDA) becomes a requirement. Even though there are some existing standards for creation, implementation, and validation of methods and models employed in industry and academics, further research and development in the field must contribute to their improvement. This review will cover, in broad terms, existing techniques as well as new developments for MVDA for Raman spectroscopic data, and in particular the use associated with instrumentation and data calibration. Chemometric models are often generated via fusion of analytical data from different sources, which enhances model discrimination and prediction abilities as compared to models derived from a single data source. For Raman spectroscopy, raw or unprocessed data is rarely ever used. Instead, spectra are usually corrected and manipulated, 1 often by case-specific rather than universal methods. Calibration models can be used to characterize qualitatively and/or quantitatively samples measured with the same instrumentation that was used to create the model. However, regular validation is required to ensure that aging or incorrect maintenance of the instrument does not alter the model’s predictions, particularly when applied in regulated fields such as pharmaceuticals. Furthermore, a model transfer may be required for different reasons, such as replacement or significant repair of the instrumentation. Modeling can also be used to consistently harmonize Raman spectroscopic data across several instrumental designs, accounting for variations in the resulting spectrum induced by different components. Data for Raman harmonization models should be processed in a protocolled manner, and the original data accessible to allow for model reconstruction or transfer when new data is added. Important processing steps will be the calibration of the spectral axes and instrument dependent effects, such as spectral resolution. In addition, data fusion and model transfer are essential for allowing new instrumentation to build on existing models to harmonize their own data. Ideally, an open access database would be created and maintained, for the purpose of allowing for continued harmonization of new Raman instruments using an outlined and accepted protocol.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, there is little concrete description of how quantitation is affected by one’s choice of numerical unmixing algorithm and the nature of the spectral bands being scrutinized, and little has been done to create consistent standard samples to interrogate quantitation robustness.21,22”
From Assessment of unmixing approaches for the quantitation of SERS nanoparticles in highly multiplexed spectral images (2024) · cites this paper as [21]
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
LOF: identifying density-based local outliers
Breunig, M. M., Kriegel, H.-P., Ng, R. T., & Sander, J. (2000) · ACM SIGMOD Record · doi:10.1145/335191.335388 · Cited by 5,207
Handbook of Vibrational Spectroscopy
(2001) · Wiley eBooks · doi:10.1002/0470027320 · Cited by 2,986
Model Selection and Multimodel Inference
(2004) · Springer eBooks · doi:10.1007/b97636 · Cited by 2,582
An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements
Cohen, E. R. (1998) · Measurement Science and Technology · doi:10.1088/0957-0233/9/6/022 · Cited by 1,499
Sternberg (1983) · Computer · doi:10.1109/mc.1983.1654163 · Cited by 930 · cited 1×
“4),(27) advanced penalized least squares approaches,(28) sensitive nonlinear iterative peak (SNIP) algorithms,(29) Goldinec,(30) spline-fitting methods, such as morphology-based cubic p-spline fitting(31) or b-spline fitting, piecewise polynomial fitting,(32) wavelet feature points,(33) convolutional neural networks,(…”
MethodThe Cambridge Dictionary of Statistics: Fourth Edition
Everitt, B. S., & Skrondal, A. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511779633 · Cited by 820
Data fusion methodologies for food and beverage authentication and quality assessment – A review
Borràs, E., Ferré, J., Boqué, R., Mestres, M., Aceña, L., & Busto, O. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.04.042 · Cited by 743
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Supervised, Unsupervised, and Semi-Supervised Feature Selection: A Review on Gene Selection
Ang, J. C., Mirzal, A., Haron, H., & Hamed, H. N. A. (2016) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2015.2478454 · Cited by 641 · cited 1×
“In general, those models can be generated through supervised or unsupervised learning.(44) Models should be trained on a sufficiently large number of known Raman spectra, the “training set” (also referred to as fitting; see Model Validation (Performance) section).”
BackgroundEilers, P. H. C. (2004) · Analytical Chemistry · doi:10.1021/ac034800e · Cited by 636
Multivariate instrument standardization
Wang, Y., Veltkamp, D. J., & Kowalski, B. R. (1991) · Analytical Chemistry · doi:10.1021/ac00023a016 · Cited by 610
(2002) · Choice Reviews Online · doi:10.5860/choice.40-0309 · Cited by 589
Chemometrics for Pattern Recognition
Brereton, R. G. (2009) · Wiley eBooks · doi:10.1002/9780470746462 · Cited by 500 · cited 1×
“A recently reported example of classification for Raman spectra is the SIMCA method, a supervised pattern recognition method in which a PCA model is constructed for each material class; for classification of a spectrum, its residual difference with each class is calculated.(45,46) Particularly for pharmaceutical appli…”
MethodConvolutional neural networks for vibrational spectroscopic data analysis
Acquarelli, J., van Laarhoven, T., Gerretzen, J., Tran, T. N., Buydens, L. M. C., & Marchiori, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.12.010 · Cited by 472
(1970) · BMJ · doi:10.1136/bmj.1.5694.449 · Cited by 400
A Note on Screening Regression Equations
Freedman, D. A. (1983) · The American Statistician · doi:10.1080/00031305.1983.10482729 · Cited by 395 · cited 1×
“Specifically with regards to regression models, the number of observations should be at least one order of magnitude larger than the number of variables considered in the model, as a lower ratio of observations to variables will lead to misleadingly high covariance statistics.(7) Moreover, the quantity of data to be c…”
HiCS: High Contrast Subspaces for Density-Based Outlier Ranking
Keller, F., Muller, E., & Bohm, K. (2012) · 2012 IEEE 28th International Conference on Data Engineering · doi:10.1109/icde.2012.88 · Cited by 373
Investigation of Selected Baseline Removal Techniques as Candidates for Automated Implementation
Schulze, G., Jirasek, A., Yu, M. M. L., Lim, A., Turner, R. F. B., & Blades, M. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053945985 · Cited by 315 · cited 1×
“compared and evaluated several baseline separation techniques for automated implementation.(39) Guo et al.”
(2011) · Springer Series in Optical Sciences · doi:10.1007/978-3-642-12522-5 · Cited by 310
Sum of ranking differences compares methods or models fairly
Héberger, K. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.09.009 · Cited by 301
Sjöblom, J., Svensson, O., Josefson, M., Kullberg, H., & Wold, S. (1998) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(98)00112-9 · Cited by 296
How to pre-process Raman spectra for reliable and stable models?
Bocklitz, T., Walter, A., Hartmann, K., Rösch, P., & Popp, J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.043 · Cited by 282 · cited 1×
“Meanwhile, model-based methods allow for quantifying and separating different types of physical and chemical variations in the spectra, for example, when a fluorescent baseline is modeled (“guessed”) and separated from the remaining data.(9,10,11) Ryabchykov et al.”
MethodAzzouz, T., & Tauler, R. (2008) · Talanta · doi:10.1016/j.talanta.2007.08.024 · Cited by 254
Baseline correction for Raman spectra using an improved asymmetric least squares method
He, S., Zhang, W., Liu, L., Huang, Y., He, J., Xie, W., Wu, P., & Du, C. (2014) · Anal. Methods · doi:10.1039/c4ay00068d · Cited by 241
Márquez, C., López, M. I., Ruisánchez, I., & Callao, M. P. (2016) · Talanta · doi:10.1016/j.talanta.2016.08.003 · Cited by 177
Bouveresse, E., & Massart, D. L. (1996) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(95)00074-7 · Cited by 164
Hedegaard, M., Matthäus, C., Hassing, S., Krafft, C., Diem, M., & Popp, J. (2011) · Theoretical Chemistry Accounts · doi:10.1007/s00214-011-0957-1 · Cited by 161
An Empirical Study on Raman Peak Fitting and Its Application to Raman Quantitative Research
Yuan, X., & Mayanovic, R. A. (2017) · Applied Spectroscopy · doi:10.1177/0003702817721527 · Cited by 156
Identification of pharmaceutical tablets by Raman spectroscopy and chemometrics
Roggo, Y., Dégardin, K., & Margot, P. A. (2010) · Talanta · doi:10.1016/j.talanta.2010.01.046 · Cited by 150 · cited 2×
“Note that all smoothing algorithms will lead to some information loss, since they correspond to annual filters in Fourier space.(2,6) Therefore, smoothing should only be used where absolutely necessary, or for intermediate steps such as baseline model fitting.”
BackgroundMishra, P., Rutledge, D. N., Roger, J., Wali, K., & Khan, H. A. (2021) · Talanta · doi:10.1016/j.talanta.2021.122303 · Cited by 146
Improved methods for fluorescence background subtraction from Raman spectra
Cadusch, P. J., Hlaing, M. M., Wade, S. A., McArthur, S. L., & Stoddart, P. R. (2013) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4371 · Cited by 142
Evaluation of an accurate calibration and spectral standardization procedure for Raman spectroscopy
Hutsebaut, D., Vandenabeele, P., & Moens, L. (2005) · The Analyst · doi:10.1039/b503624k · Cited by 140
Algorithm for optimal denoising of Raman spectra
Barton, S. J., Ward, T. E., & Hennelly, B. M. (2018) · Analytical Methods · doi:10.1039/c8ay01089g · Cited by 129 · cited 1×
“Information loss by smoothing can be mitigated by the implementation of maximum likelihood estimation (MLE).(25) By restricting the behavior of the smoothing algorithm based on the distribution of the noise, MLE is able to reduce the impact of smoothing on the Raman signal.”
MethodApplication of modified alternating least squares regression to spectroscopic image analysis
Wang, J., Hopke, P. K., Hancewicz, T. M., & Zhang, S. L. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)01369-7 · Cited by 122
Optimization of Raman-spectrum baseline correction in biological application
Guo, S., Bocklitz, T., & Popp, J. (2016) · The Analyst · doi:10.1039/c6an00041j · Cited by 109 · cited 1×
“report a method of automated selection of a baseline algorithm that optimizes a specific model.(40) This potential model specificity of the baseline separation method underlines the need to preserve the original training data with any model to modify the baseline separation procedure if needed.”
MethodRaman spectroscopy and chemometrics: A potential universal method for diagnosing cancer
Ralbovsky, N. M., & Lednev, I. K. (2019) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2019.04.067 · Cited by 107
Comparability of Raman Spectroscopic Configurations: A Large Scale Cross-Laboratory Study
Guo, S., Beleites, C., Neugebauer, U., Abalde-Cela, S., Afseth, N. K., Alsamad, F., Anand, S., Araujo-Andrade, C., Aškrabić, S., Avci, E., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02696 · Cited by 101
Optimal cross-validation in density estimation with the $L^{2}$-loss
Célisse, A. (2014) · The Annals of Statistics · doi:10.1214/14-aos1240 · Cited by 100
Standardization of Raman spectra for transfer of spectral libraries across different instruments
Rodriguez, J. D., Westenberger, B. J., Buhse, L. F., & Kauffman, J. F. (2011) · The Analyst · doi:10.1039/c1an15636e · Cited by 99
Baldomero‐Naranjo, M., Martínez-Merino, L. I., & Rodríguez-Chía, A. M. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2021.115017 · Cited by 94
Raman Spectroscopy and Genetic Algorithms for the Classification of Wood Types
Lavine, B. K., Davidson, C. E., Moores, A. J., & Griffiths, P. R. (2001) · Applied Spectroscopy · doi:10.1366/0003702011953108 · Cited by 89
Improved Baseline Correction Method Based on Polynomial Fitting for Raman Spectroscopy
Hu, H., Bai, J., Xia, G., Zhang, W., & Ma, Y. (2018) · Photonic Sensors · doi:10.1007/s13320-018-0512-y · Cited by 88
Computer fitting of Voigt profiles to Raman lines
Sundius, T. (1973) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250010506 · Cited by 84
Goldindec: A Novel Algorithm for Raman Spectrum Baseline Correction
Liu, J., Sun, J., Huang, X., Li, G., & Liu, B. (2015) · Applied Spectroscopy · doi:10.1366/14-07798 · Cited by 82
Tulsyan, A., Schorner, G., Khodabandehlou, H., Wang, T., Coufal, M., & Undey, C. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27100 · Cited by 82
Checking and Improving Calibration of Raman Spectra using Chemometric Approaches
Dörfer, T., Bocklitz, T., Tarcea, N., Schmitt, M., & Popp, J. (2011) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.2011.0077 · Cited by 81 · cited 3×
“This highlights the importance of harmonization for Raman instrumentation, data acquisition, and processing.(4)”
BackgroundMethodA comprehensive study of classification methods for medical diagnosis
Bocklitz, T., Putsche, M., Stüber, C., Käs, J., Niendorf, A., Rösch, P., & Popp, J. (2009) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2529 · Cited by 79
Analyzing Raman spectroscopic data
Ryabchykov, O., Guo, S., & Bocklitz, T. (2019) · Physical Sciences Reviews · doi:10.1515/psr-2017-0043 · Cited by 74
Calibration Maintenance and Transfer Using Tikhonov Regularization Approaches
Kalivas, J. H., Siano, G. G., Andries, E., & Goicoechea, H. C. (2009) · Applied Spectroscopy · doi:10.1366/000370209788701206 · Cited by 73
Review of Existing Standards, Guides, and Practices for Raman Spectroscopy
Ntziouni, A., Thomson, J., Xiarchos, I., Li, X., Bañares, M. A., Charitidis, C., Portela, R., & Lozano Diz, E. (2022) · Applied Spectroscopy · doi:10.1177/00037028221090988 · Cited by 73
Self-citationIterative morphological and mollifier‐based baseline correction for Raman spectra
Koch, M., Suhr, C., Roth, B., & Meinhardt‐Wollweber, M. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5010 · Cited by 62
Qian, F., Wu, Y., & Peng, H. (2017) · Optics & Laser Technology · doi:10.1016/j.optlastec.2017.05.021 · Cited by 57
An asymmetric fitting function for condensed-phase Raman spectroscopy
Korepanov, V. I., & Sedlovets, D. M. (2018) · The Analyst · doi:10.1039/c8an00710a · Cited by 57
Fundamentals of Calibration Transfer through Procrustes Analysis
Anderson, C. E., & Kalivas, J. H. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945515 · Cited by 53
Factors Affecting the Performance of Bench-Top Raman Spectrometers. Part I: Instrumental Effects
Bowie, B. T., Chase, D. B., Griffiths, P. R., & Pont, D. (2000) · Applied Spectroscopy · doi:10.1366/0003702001949924 · Cited by 50
Outliers in rules - the comparision of LOF, COF and KMEANS algorithms.
Nowak-Brzezińska, A., & Horyń, C. (2020) · Procedia Computer Science · doi:10.1016/j.procs.2020.09.152 · Cited by 50
Guo, S., Kohler, A., Zimmermann, B., Heinke, R., Stöckel, S., Rösch, P., Popp, J., & Bocklitz, T. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01536 · Cited by 48
Low‐level LIBS and Raman data fusion in the context of in situ Mars exploration
Rammelkamp, K., Schröder, S., Kubitza, S., Vogt, D., Frohmann, S., Hansen, P. B., Böttger, U., Hanke, F., & Hübers, H. (2019) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5615 · Cited by 48
Local classification: Locally weighted–partial least squares-discriminant analysis (LW–PLS-DA)
Bevilacqua, M., & Marini, F. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.05.057 · Cited by 47
A consensus modeling approach to update a spectroscopic calibration
Shahbazikhah, P., & Kalivas, J. H. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.06.006 · Cited by 47
Quantitative Evaluation of the Sensitivity of Library-Based Raman Spectral Correlation Methods
Rodriguez, J. D., Westenberger, B. J., Buhse, L. F., & Kauffman, J. F. (2011) · Analytical Chemistry · doi:10.1021/ac200040b · Cited by 46 · cited 2×
“950 is often used as a simple model for material verification (classification).(47) As an example, calibration and deployment of Raman models for pharmaceutical online process monitoring has been described to involve four main steps:(43) (i) Collection of well-characterized spectral and analytical data for the paramet…”
BackgroundMethodTowards an improvement of model transferability for Raman spectroscopy in biological applications
Guo, S., Heinke, R., Stöckel, S., Rösch, P., Bocklitz, T. W., & Popp, J. (2016) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2016.06.010 · Cited by 43
Model transfer for Raman‐spectroscopy‐based bacterial classification
Guo, S., Heinke, R., Stöckel, S., Rösch, P., Popp, J., & Bocklitz, T. (2018) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5343 · Cited by 41
Leion, H., Folestad, S., Josefson, M., & Sparén, A. (2004) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2004.09.046 · Cited by 40
González‐Vidal, J. J., Pueyo, R. P., & Soneira, M. J. (2017) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5130 · Cited by 39
ISREA: An Efficient Peak-Preserving Baseline Correction Algorithm for Raman Spectra
Xu, Y., Du, P., Senger, R. S., Robertson, J. L., & Pirkle, J. L. (2020) · Applied Spectroscopy · doi:10.1177/0003702820955245 · Cited by 39
Hutchings, J. C., Kendall, C. A., Shepherd, N. A., Barr, H., & Stone, N. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3512244 · Cited by 36
Gryniewicz-Ruzicka, C. M., Rodriguez, J. D., Arzhantsev, S., Buhse, L. F., & Kauffman, J. F. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.12.002 · Cited by 35 · cited 3×
“A recently reported example of classification for Raman spectra is the SIMCA method, a supervised pattern recognition method in which a PCA model is constructed for each material class; for classification of a spectrum, its residual difference with each class is calculated.(45,46) Particularly for pharmaceutical appli…”
MethodOkajima, H., & Hamaguchi, H. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4731 · Cited by 28 · cited 1×
“Hereby, Raman spectrometers and detectors are prepared in the same way as for other spectroscopy techniques, based on correlating detector pixels with the known signal generated by external references, such as gas emission lines.(13) Raman shift x-axis calibration is then performed by defining the incident laser wavel…”
MethodLi, W., & Huang, Y. Q. (2020) · Applied Ocean Research · doi:10.1016/j.apor.2020.102301 · Cited by 23
Brouckaert, D., Uyttersprot, J.-S., Broeckx, W., & Beer, T. D. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.049 · Cited by 22
Multi-way based calibration transfer between two Raman spectrometers
Kompany‐Zareh, M., & van den Berg, F. W. J. (2010) · The Analyst · doi:10.1039/b927501k · Cited by 19
Li, Q., Sun, X., Ma, X., Li, B., Wang, H., Lv, H., Wang, Q., Xu, K., & Chen, D. (2019) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2019.07.004 · Cited by 16
Practices for Infrared Multivariate Quantitative Analysis
E13 Committee (2017) · ASTM Standards · doi:10.1520/e1655-17 · Cited by 15
Non-linear Raman scattering intensities in graphene
Giegold, V., Lange, L., Ciesielski, R., & Hartschuh, A. (2020) · Nanoscale · doi:10.1039/c9nr10654e · Cited by 13 · cited 1×
“However, the relationships of peaks and their behavior do not always act linearly, as can be seen in the Raman peak intensities from graphene.(42) Raman spectra can be scaled in a non-linear fashion to increase the relative weights of some spectral features, such as through a logarithmic, square root or power transfor…”
BackgroundStudy on early rice blast diagnosis based on unpre-processed Raman spectral data
Zhao, X., Liu, Z., He, Y., Zhang, W., & Tong, L. (2020) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.118255 · Cited by 11 · cited 1×
“Meanwhile, model-based methods allow for quantifying and separating different types of physical and chemical variations in the spectra, for example, when a fluorescent baseline is modeled (“guessed”) and separated from the remaining data.(9,10,11) Ryabchykov et al.”
MethodFéré, M., Piot, O., Liu, L. H., Beljebbar, A., Untereiner, V., Gheldof, D. D., Chollat, M., Klossa, J., Châtelain, B., & Gobinet, C. (2019) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2019.102931 · Cited by 10 · cited 1×
“Meanwhile, model-based methods allow for quantifying and separating different types of physical and chemical variations in the spectra, for example, when a fluorescent baseline is modeled (“guessed”) and separated from the remaining data.(9,10,11) Ryabchykov et al.”
MethodBrouckaert, D., Uyttersprot, J.-S., Broeckx, W., & Beer, T. D. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.07.044 · Cited by 8
Methods for Improving Signal to Noise Ratio in RamanSpectra
Barton, S. J. (2019) · Maynooth University ePrints and eTheses Archive (Maynooth University) · Cited by 6
Reverse Intensity Correction for Raman Spectral Library Search
Zhao, J., Frano, K. A., & Zhou, J. X. (2017) · Applied Spectroscopy · doi:10.1177/0003702817694381 · Cited by 4 · cited 1×
“One method, proposed to avoid this problem, is to apply the intensity correction in reverse to an intensity corrected library spectrum and then compare that with the spectrum collected on a separate instrument.(16)”
MethodBaseline Correction and Denoising of Raman Spectra by Deep Residual CNN
Kung, B.-H., Huang, C.-C., Hu, P.-Y., Lo, S.-Y., Lee, C.-C., Yao, C.-Y., & Kuan, C.-H. (2020) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2020.jtu2g.28 · Cited by 4
(2021) · USP-NF · doi:10.31003/uspnf_m8188_02_01 · Cited by 4
E13 Committee (2016) · ASTM Standards · doi:10.1520/e2056-04r16 · Cited by 3
Guide for Multivariate Data Analysis in Pharmaceutical Development and Manufacturing Applications
E55 Committee (2020) · ASTM Standards · doi:10.1520/e2891-20 · Cited by 2
D02 Committee (2021) · ASTM Standards · doi:10.1520/d6122-21 · Cited by 2
Research works printed but not linked: 19
- National Institute of Standards and Technology (NIST), 2019, SRM 2242a. Relative Intensity Correction Standard for Raman Spectroscopy: 532 nm Excitation
- Ozog D., 2017, Signal Processing
- Beleites C., Sergo V. “Chemometric Analysis of Spectroscopic Data in R: HyperSpec”. Poster presented at: 13th European Conference on the Spectroscopy of Biological Molecules (ECSBM). Palermo, Italy; 28 August–2 September 2009. https://hyperspec.r-forge.r-project.org/blob/Beleites2009.pdf [accessed Mar 25 2022].
- Demšar J., 2013, J. Machine Learning Res, 14, 2349
- Barton B., Zou M., Geertz G., Metsch-Zillingen E., Brüll R. “Raman Imaging of Additives in Polymers: Multivariate Decomposition of 3D Maps and Super-Resolution Imaging”. Presented at: International Conference for Chemical Characterization and Imaging. Ulm, Germany; 23–25 September 2019.
- Demšar J., 2013, J. Mach. Learn. Res, 14, 2349
- Powers D.M.W. “What the F-Measure Doesn’t Measure: Features, Flaws, Fallacies and Fixes”. ArXiv. 2015. https://arxiv.org/ftp/arxiv/papers/1503/1503.06410.pdf [accessed Mar 25 2022].
- National Institute of Standards and Technology (NIST), 2022, SRM 2241 Relative Intensity Correction Standard for Raman Spectroscopy: 785 nm Excitation
- 10.1520/E1654-94R13.2 · doi:10.1520/e1654-94r13.2
- 10.1520/E1683-02R14E01.2 · doi:10.1520/e1683-02r14e01.2
- ASTM International, 2014, ASTM E1840–96 Standard Guide for Raman Shift Standards for Spectrometer Calibration
- ASTM International, 2014, ASTM E2529–06 Standard Guide for Testing the Resolution of a Raman Spectrometer
- ASTM International, 2013, ASTM E2911–13 Standard Guide for Relative Intensity Correction of Raman Spectrometers
- ASTM International, 2017, ASTM E2617–17 Standard Practice for Validation of Empirically Derived Multivariate Calibrations
- 10.31003/USPNF_M8188_02_01 · DOI
- United States Pharmacopeial Convention, 2020, <1039> Chemometrics
- ASTM International, 2002, ASTM E456–02 Standard Terminology Relating to Quality and Statistics
- ASTM International, 2021, ASTM E178–21 Standard Practice for Dealing with Outlying Observations
- 10.1039/c1an15636e · DOI
Cited by
Artifacts and Anomalies in Raman Spectroscopy: A Review on Origins and Correction Procedures
Vulchi, R. T., Morgunov, V., Junjuri, R., & Bocklitz, T. W. (2024) · Molecules · doi:10.3390/molecules29194748 · Cited by 123
RamanSPy: An Open-Source Python Package for Integrative Raman Spectroscopy Data Analysis
Georgiev, D., Pedersen, S. V., Xie, R., Fernández-Galiana, Á., Stevens, M. M., & Barahona, M. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c00383 · Cited by 108
Review of Existing Standards, Guides, and Practices for Raman Spectroscopy
Ntziouni, A., Thomson, J., Xiarchos, I., Li, X., Bañares, M. A., Charitidis, C., Portela, R., & Lozano Diz, E. (2022) · Applied Spectroscopy · doi:10.1177/00037028221090988 · Cited by 73
Self-citationTang, J., Yuan, Q., Zhang, L., Marshall, B. J., Tay, C. Y., & Wang, L. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118135 · Cited by 74
Xuesong, H., Chen, P., Li, J., Xu, Y., Liu, D., & Chu, X. (2023) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2023.2204946 · Cited by 58
Metadata
- Authors
- Barton, B., Thomson, J., Lozano Diz, E., & Portela, R.
- Affiliations
- Fraunhofer Institute for Structural Durability and System Reliability (DE)
- ELODIZ Ltd, High Wycombe, UK
- Consejo Superior de Investigaciones Científicas (ES)
- Corresponding author
- Portela, Raquel
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2022-05-27
- Volume
- 76
- Issue
- 9
- Pages
- 1021-1041
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W4281956143
- Cited by
- 79
- References
- 87
- Citations by year
- 2026: 20 · 2025: 24 · 2024: 24 · 2023: 10 · 2022: 1
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Applied Spectroscopy (publishedVersion)
- PubMed (publishedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Funders
- European Commission (952921)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Mathematics › Statistics and Probability › Advanced Statistical Methods and Models
- Keywords
- Raman spectroscopy, multivariate analysis, chemometrics, data harmonization, calibration models, model transfer, data fusion, spectral calibration, spectral resolution, model validation, model reconstruction, pharmaceutical analysis
- MeSH terms
- Chemometrics, Calibration, Pharmaceutical Preparations, Spectrum Analysis, Raman
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.