Background: Point-of-care testing has been developed to provide rapid test results. Most published studies focus on analytical performance, neglecting its impact on patient outcomes. Objective: To review the analytical performance and accuracy of point-of-care testing specifically planned for immunoassay and to evaluate the impact of faster results on patient management. Methods: A search of electronic databases for studies reporting immunoassay results obtained in both point-of-care testing and central laboratory scenarios was performed. Data were extracted concerning the study details, and the methodological quality was assessed. The analytical characteristics and diagnostic accuracy of six points-of-care testing: troponin, procalcitonin, parathyroid hormone, brain natriuretic peptide, C-reactive protein and neutrophil gelatinase-associated lipocalin were evaluated. Results: A total of 116 scientific papers were analysed. Studies measuring procalcitonin, parathyroid hormone and neutrophil gelatinase-associated lipocalin reported a limited impact on diagnostic decisions. Seven studies measuring C-reactive protein claimed a significant reduction of antibiotic prescription. Several authors evaluated brain natriuretic peptide or troponin reporting faster decision-making without any improvement in clinical outcome. Forty-four per cent of studies reported analytical data, showing satisfactory correlations between results obtained through point-of-care testing and central laboratory setting. Half of studies defined the diagnostic accuracy of point-of-care testing as acceptable for troponin (median sensitivity and specificity: 74% and 94%, respectively), brain natriuretic peptide (median sensitivity and specificity: 82% and 88%, respectively) and C-reactive protein (median sensitivity and specificity 85%). Conclusions: Point-of-care testing immunoassay results seem to be reliable and accurate for troponin, brain natriuretic peptide and C-reactive protein. The satisfactory analytical performance, together with an excellent practicability, suggests that it could be a consistent tool in clinical practice, but data are lacking regarding the patient outcomes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Studies on POCT issue mostly report analytical performances (central laboratory vs. POCT) which are usually acceptable but do not report patient outcomes assessment [57].”
From Point-of-care testing: state-of-the art and perspectives (2025) · cites this paper as [57]
Citations
Cites
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & the PRISMA Group* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00135 · Cited by 37,554
Diagnostic point-of-care tests in resource-limited settings
Drain, P. K., Hyle, E. P., Noubary, F., Freedberg, K. A., Wilson, D., Bishai, W. R., Rodriguez, W., & Bassett, I. V. (2014) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70250-0 · Cited by 744 · cited 1×
“Furthermore, some authors showed as the usefulness of POCT in faster decision-making, influencing treatment and further care,(128) supporting clinical decisions and stratifying patients,(5) but only in specific environments when access to care is limited or in case of environmental disasters.(129,130) The literature e…”
BackgroundDent, C. L., Ma, Q., Dastrala, S., Bennett, M., Mitsnefes, M. M., Barasch, J., & Devarajan, P. (2007) · Critical Care · doi:10.1186/cc6192 · Cited by 483 · cited 1×
“NGAL Dent et al.(66) Prospective 120 Paediatric Unclear”
BackgroundHarrison, A., Morrison, L. K., Krishnaswamy, P., Kazanegra, R., Clopton, P., Dao, Q., Hlavin, P., & Maisel, A. S. (2002) · Annals of Emergency Medicine · doi:10.1067/mem.2002.121483 · Cited by 372 · cited 1×
“BNP Harrison et al.(16) Diagnosis 325 ED Adequate”
BackgroundPrice, C. P. (2001) · BMJ · doi:10.1136/bmj.322.7297.1285 · Cited by 368
McCord, J., Nowak, R. M., McCullough, P. A., Foreback, C., Borzak, S., Tokarski, G., Tomlanovich, M. C., Jacobsen, G., & Weaver, W. D. (2001) · Circulation · doi:10.1161/hc3801.096336 · Cited by 297 · cited 1×
“TnI, CK-MB, Myo McCord et al.(104) Observational 817 ED Adequate”
BackgroundCals, J. W. L., Schot, M. J. C., de Jong, S. A. M., Dinant, G.-J., & Hopstaken, R. M. (2010) · The Annals of Family Medicine · doi:10.1370/afm.1090 · Cited by 211 · cited 1×
“CRP Cals et al.(43) RCT 258 Primary care Adequate”
BackgroundPoint of care testing: randomised controlled trial of clinical outcome
Kendall, J., Reeves, B., & Clancy, M. (1998) · BMJ · doi:10.1136/bmj.316.7137.1052 · Cited by 200
Wieczorek, S. J., Wu, A. H. B., Christenson, R., Krishnaswamy, P., Gottlieb, S., Rosano, T., Hager, D., Gardetto, N., Chiu, A., Ba illy, K. R., et al. (2002) · American Heart Journal · doi:10.1016/s0002-8703(02)80017-5 · Cited by 182 · cited 1×
“BNP Wieczorek et al.(36) Comparative 882 Triage Adequate”
BackgroundNinety-minute accelerated critical pathway for chest pain evaluation
Ng, S. M., Krishnaswamy, P., Morissey, R., Clopton, P., Fitzgerald, R., & Maisel, A. S. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01801-x · Cited by 171 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundImpact of point-of-care testing on patients' length of stay in a large emergency department
Parvin, C. A., Lo, S. F., Deuser, S. M., Weaver, L. G., Lewis, L. M., & Scott, M. G. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.5.711 · Cited by 164 · cited 1×
“Several studies, evaluating the benefit of POCT in emergency department (ED), reported a significant decrease of TAT, but this effect did not lead to shorter length of stay (LOS)(6) or to drive the decision-making process.(7) Furthermore, the main advantages of POCT may be the early and appropriate support to diagnosi…”
BackgroundProsen, G., Klemen, P., Strnad, M., & Grmec, Š. (2011) · Critical Care · doi:10.1186/cc10140 · Cited by 161 · cited 1×
“NT-proBNP Prosen et al.(29) Prospective 218 ED Adequate”
BackgroundThe state of point-of-care testing: a european perspective
Larsson, A., Greig-Pylypczuk, R., & Huisman, A. (2015) · Upsala Journal of Medical Sciences · doi:10.3109/03009734.2015.1006347 · Cited by 159 · cited 1×
“The implementation of POCT is successful when the performed assay is helpful for medical decision-making and does not need additional testing for confirmation from a central laboratory.(4) New technologies in POCT should deliver to clinicians rapid and reliable test results, and high analytical and diagnostic performa…”
Goodacre, S. W., Bradburn, M., Cross, E., Collinson, P., Gray, A., & Hall, A. S. (2011) · Heart · doi:10.1136/hrt.2010.203166 · Cited by 151 · cited 1×
“TnI, CK-MB, Myo Goodacre et al.(96) RCT 2243 ED Adequate”
BackgroundRisk stratification with a point-of-care cardiac troponin T test in acute myocardial infarction
Ohman, E. M., Armstrong, P. W., White, H. D., Granger, C. B., Wilcox, R. G., Weaver, W. D., Gibler, W. B., Stebbins, A., Cianciolo, C., Califf, R. M., et al. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00558-5 · Cited by 136 · cited 1×
“TnT Ohman et al.(109) Prospective 12666 ED Adequate”
BackgroundIntraoperative Parathyroid Hormone Analysis: A Study of 200 Consecutive Cases
Sokoll, L. J., Drew, H., & Udelsman, R. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.10.1662 · Cited by 133 · cited 1×
“PTH Sokoll et al.(76) Cohort 200 Surgery Adequate”
BackgroundHuang, Y., Chen, R., Wu, T., Wei, X., & Guo, A. (2013) · British Journal of General Practice · doi:10.3399/bjgp13x674477 · Cited by 130 · cited 1×
“Seven studies evaluating CRP showed a significant decrease of antibiotic prescription, also proven in a previous systematic review.(121) Several studies evaluating BNP or Tn highlighted the usefulness of rapid tests especially in ED.”
ResultAndreeva, E., & Melbye, H. (2014) · BMC Family Practice · doi:10.1186/1471-2296-15-80 · Cited by 105
Cals, J., Ament, A. J. H. A., Hood, K., Butler, C., Hopstaken, R., Wassink, G. F., & Dinant, G. (2010) · Journal of Evaluation in Clinical Practice · doi:10.1111/j.1365-2753.2010.01472.x · Cited by 104 · cited 1×
“CRP Cals et al.(44) RCT 431 Primary care Adequate”
BackgroundCardiac troponin: a critical review of the case for point-of-care testing in the ED
Bingisser, R. M., Cairns, C. B., Christ, M., Hausfater, P., Lindahl, B., Mair, J. M., Panteghini, M., Price, C. P., & Venge, P. (2012) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2012.03.004 · Cited by 99
Heeschen, C., Goldmann, B. U., Langenbrink, L., Matschuck, G., & Hamm, C. W. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.10.1789 · Cited by 97 · cited 1×
“TnI, CK-MB, Myo Heeschen et al.(99) Observational 412 ED Adequate”
BackgroundJakobsen, K. A., Melbye, H., Kelly, M. J., Ceynowa, C., Mölstad, S., Hood, K., & Butler, C. (2010) · Scandinavian Journal of Primary Health Care · doi:10.3109/02813432.2010.506995 · Cited by 94 · cited 1×
“CRP Jakobsen et al.(49) Prospective 803 Primary care Adequate”
BackgroundSomma, S. D., Magrini, L., Berardinis, B. D., Marino, R., Ferri, E., Moscatelli, P., Ballarino, P., Carpinteri, G., Noto, P., Gliozzo, B., et al. (2013) · Critical Care · doi:10.1186/cc12510 · Cited by 91 · cited 1×
“NGAL Di Somma et al.(67) Prospective 160 ED Adequate”
BackgroundEvaluation of a New, Rapid Bedside Test for Quantitative Determination of B-Type Natriuretic Peptide
Fischer, Y., Filzmaier, K., Stiegler, H., Graf, J., Fuhs, S., Franke, A., Janssens, U., & Gressner, A. M. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.3.591 · Cited by 84 · cited 1×
“BNP Fischer et al.(13) Comparative 145 Triage Adequate”
Agarwal, G., Barakate, M. S., Robinson, B. G., Wilkinson, M. R., Barraclough, B. H., Reeve, T. S., & Delbridge, L. (2001) · Surgery · doi:10.1067/msy.2001.118376 · Cited by 83 · cited 1×
“PTH Agarwal et al.(72) Prospective 92 Surgery Adequate”
BackgroundAnalytical performance of the i-STAT cardiac troponin I assay
Apple, F. S., Murakami, M. M., Christenson, R. H., Campbell, J. L., Miller, C. J., Hock, K. G., & Scott, M. G. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.03.010 · Cited by 80 · cited 1×
“TnI Apple et al.(80) Observational 186 samples ED Adequate”
BackgroundJohnson, L. R., Doherty, G. M., Lairmore, T. C., Moley, J. F., Brunt, L. M., Koenig, J. W., & Scott, M. G. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.5.919 · Cited by 79 · cited 1×
“PTH Johnson et al.(75) Cohort 55 Surgery Unclear”
BackgroundWu, A. H. B., Smith, A. M., Christenson, R. H., Murakami, M. M., & Apple, F. S. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.03.036 · Cited by 78 · cited 1×
“TnI, CK-MB Wu et al.(120) Comparative 180 Not defined Adequate”
BackgroundMeisner, M., Brunkhorst, F. M., Reith, H. B., Schmidt, J., Lestin, H.-G., & Reinhart, K. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.147 · Cited by 78 · cited 1×
“PCT Meisner et al.(71) Comparative 237 samples Intensive care Adequate”
BackgroundB-type natriuretic peptide (BNP)--validation of an immediate response assay.
Vogeser, M., & Jacob, K. (2001) · PubMed · Cited by 76
Heeschen, C., Goldmann, B. U., Moeller, R. H., & Hamm, C. W. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.9.1925 · Cited by 71 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundPrehospital testing for troponin T in patients with suspected acute myocardial infarction
Schuchert, A., Hamm, C. W., Scholz, J., Klimmeck, S., Goldmann, B. U., & Meinertz, T. (1999) · American Heart Journal · doi:10.1016/s0002-8703(99)70244-9 · Cited by 70 · cited 1×
“TnT Schuchert et al.(114) Observational 158 ED Adequate”
BackgroundClerico, A., Prontera, C., Emdin, M., Passino, C., Storti, S., Poletti, R., Zyw, L., & Zucchelli, G. C. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.038281 · Cited by 70 · cited 1×
“BNP, NT-proBNP Cleric ort al.(10) Comparative 451 Not specify Adequate”
Backgroundden Bruel, A. V., Jones, C., Thompson, M., & Mant, D. (2016) · Archives of Disease in Childhood · doi:10.1136/archdischild-2015-309228 · Cited by 69
Evaluation of fluorescence hs-CRP immunoassay for point-of-care testing
Oh, S. W., Moon, J. D., Park, S. Y., Jang, H. J., Kim, J. H., Nahm, K. B., & Choi, E. Y. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.01.026 · Cited by 68 · cited 1×
“CRP Oh et al.(57) Comparative 150 Not defined Unclear”
BackgroundAsha, S. E., Chan, A. C. F., Walter, E., Kelly, P. J., Morton, R. L., Ajami, A., Wilson, R. D., & Honneyman, D. (2014) · Emergency Medicine Journal · doi:10.1136/emermed-2013-202632 · Cited by 67 · cited 7×
“The details included: (a) characteristic of the study: authors, reference, study design; (b) characteristics of patients (age, sex, number of sample for each patients group); (c) data about analytical performance of the test; (d) diagnostic accuracy outcomes: Sn, Sp, PPV and NPV; (e) patient important outcomes: number…”
BackgroundResultInfluentialMüller-Bardorff, M., Rauscher, T., Kampmann, M., Schoolmann, S., Laufenberg, F., Mangold, D., Zerback, R., Remppis, A. B., & Katus, H. A. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.1002 · Cited by 66 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundValidation and evaluation of eight commercially available point of care CRP methods
Brouwer, N., & PELT, J. V. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.10.028 · Cited by 66
Dahler-Eriksen, B. S., Lauritzen, T., Lassen, J. F., Lund, E. D., & Brandslund, I. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.4.478 · Cited by 64 · cited 1×
“CRP Dahler-Eriksen et al.(45) RCT 1853 Primary care Adequate”
BackgroundCarneiro, D. M., & Irvin, G. L. (2002) · World Journal of Surgery · doi:10.1007/s00268-002-6675-z · Cited by 64
Sørensen, J. T., Terkelsen, C. J., Stengaard, C., Lassen, J. F., Trautner, S., Christensen, E. F., Nielsen, T. T., Bøtker, H. E., Andersen, H., & Thygesen, K. A. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.01.014 · Cited by 63 · cited 1×
“TnT Sørensen et al.(116) Observational 4905 ED Adequate”
BackgroundWei, T., Zeng, C., Chen, L., Chen, Q., Zhao, R., Lu, G., Lu, C., & Wang, L. (2004) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2004.03.015 · Cited by 63 · cited 1×
“BNP Wei et al.(35) Diagnostic 84 Cardiology department Adequate”
BackgroundApple, F. S., Ler, R., Chung, A., Berger, M. J., & Murakami, M. M. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.060293 · Cited by 62 · cited 1×
“TnI Apple et al.(81) Prospective 400 ED Adequate”
BackgroundMinnaard, M. C., van de Pol, A. C., Broekhuizen, B. D., Verheij, T. J., Hopstaken, R., van Delft, S., Kooijman-Buiting, A. M. J., de Groot, J. A. H., & de Wit, N. J. (2013) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2013.841985 · Cited by 62 · cited 1×
“CRP Minnaard et al.(54) Comparative Not clear Not defined Unclear”
BackgroundA prospective randomized controlled trial of point-of-care testing on the coronary care unit
Collinson, P., John, C., Lynch, S., Rao, A., Canepa-Anson, R., Carson, E., & Cramp, D. (2004) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563041731547 · Cited by 62 · cited 3×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundResultRenaud, B., Maison, P., Ngako, A., Cunin, P., Santin, A., Hervé, J., Salloum, M., Calmettes, M., Boraud, C., Lemiale, V., et al. (2008) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2008.00069.x · Cited by 61 · cited 3×
“New technologies in POCT should deliver to clinicians rapid and reliable test results, and high analytical and diagnostic performance, to reduce the incidence of false-negative or false-positive results which could lead to unjustified medical interventions.(5) Several studies, evaluating the benefit of POCT in emergen…”
BackgroundResultTomonaga, Y., Gutzwiller, F., Lüscher, T. F., Riesen, W. F., Hug, M., Diemand, A., Schwenkglenks, M. M., & Szucs, T. D. (2011) · BMC Family Practice · doi:10.1186/1471-2296-12-12 · Cited by 57 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundPoint-of-care testing: where is the evidence? A systematic survey
Pecoraro, V., Germagnoli, L., & Banfi, G. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0386 · Cited by 56 · cited 2×
“As evaluated in a previous survey, most studies evaluated surrogate outcomes only, which do not directly impact clinical outcomes.(3) The implementation of POCT is successful when the performed assay is helpful for medical decision-making and does not need additional testing for confirmation from a central laboratory.”
BackgroundResultSelf-citationHur, M., Kim, H., Lee, S., Cristofano, F., Magrini, L., Marino, R., Gori, C. S., Bongiovanni, C., Zancla, B., Cardelli, P., et al. (2014) · BMC Infectious Diseases · doi:10.1186/1471-2334-14-224 · Cited by 55 · cited 1×
“PCT, BNP, NGAL Hur et al.(69) Prospective 340 ED Adequate”
MethodStengaard, C., Sørensen, J. T., Ladefoged, S. A., Christensen, E. F., Lassen, J. F., Bøtker, H. E., Terkelsen, C. J., & Thygesen, K. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.06.026 · Cited by 55 · cited 1×
“TnT Stengaard et al.(115) Prospective 985 Ambulances Adequate”
BackgroundLoten, C., Attia, J., Hullick, C., Marley, J., & McElduff, P. (2010) · Emergency Medicine Journal · doi:10.1136/emj.2008.069427 · Cited by 53 · cited 1×
“TnI Loten et al.(103) RCT 1194 ED Adequate”
BackgroundKnudsen, C. W., Riis, J. S., Finsen, A. V., Eikvar, L., Müller, C., Westheim, A. S., & Omland, T. (2003) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2003.10.006 · Cited by 53 · cited 1×
“BNP Knudsen et al.(19) Diagnosis 155 ED Unclear”
BackgroundCollinson, P. O., Goodacre, S. W., Gaze, D. C., & Gray, A. J. (2011) · Heart · doi:10.1136/heartjnl-2011-300723 · Cited by 51 · cited 1×
“TnI, CK-MB Collinson et al.(88) RCT 2263 ED Adequate”
BackgroundDiercks, D. B., Peacock, W. F., Hollander, J. E., Singer, A. J., Birkhahn, R., Shapiro, N. I., Glynn, T., Nowak, R., Safdar, B., Miller, C. D., et al. (2011) · American Heart Journal · doi:10.1016/j.ahj.2011.09.028 · Cited by 51 · cited 1×
“TnI Diercks et al.(90) Observational 858 ED Adequate”
BackgroundGonzales, R., Aagaard, E., Camargo, C. A., Ma, O. J., Plautz, M. W., Maselli, J. H., McCulloch, C. E., Levin, S. K., & Metlay, J. P. (2008) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2008.06.021 · Cited by 47 · cited 1×
“CRP Gonzales et al.(48) RCT 131 ED Adequate”
BackgroundSambursky, R. P., & Shapiro, N. I. (2015) · European Clinical Respiratory Journal · doi:10.3402/ecrj.v2.28245 · Cited by 47
Venge, P., Öhberg, C., Flodin, M., & Lindahl, B. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.07.036 · Cited by 46 · cited 1×
“TnI Venge et al.(119) Prospective 1069 ED Adequate”
BackgroundEvaluation of a rapid bedside test for the quantitative determination of C-reactive protein
Esposito, S., Tremolati, E., Begliatti, E., Bosis, S., Gualtieri, L., & Principi, N. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.077 · Cited by 45 · cited 1×
“CRP Esposito et al.(47) Cohort 231 Paediatric Adequate”
BackgroundRy, S. D., Giannessi, D., & Clerico, A. (2001) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2001.070 · Cited by 45 · cited 1×
“BNP Del Ry et al.(11) Comparative 83 Samples Laboratory of cardiovascular end.”
The need for a point of care testing: An evidence-based appraisal
Collinson, P. O. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519909168329 · Cited by 44 · cited 1×
“In ED, where POCT for immunoassay is commonly applied, the availability of early and reliable diagnostic biomarkers for cardiac disease is especially useful in the provision of timely and accurate AMI diagnosis,(122) thereby reducing the incidence of inappropriate diagnosis.(123) Despite the rapid TAT, early POCT had…”
MethodSeamark, D., Backhouse, S., & Powell, R. J. (2003) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456303763046139 · Cited by 42 · cited 1×
“CRP Seamark et al.(61) Comparative NR Primary care Inadequate”
BackgroundBock, J. L., Singer, A. J., & Thode, H. C. (2008) · American Journal of Clinical Pathology · doi:10.1309/nvxh8dl5hwfdnb74 · Cited by 42 · cited 1×
“TnI Bock et al.(85) Comparative 5909 ED Adequate”
BackgroundPalamalai, V., Murakami, M. M., & Apple, F. S. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.06.026 · Cited by 40 · cited 1×
“TnI Palamalai et al.(111) Observational 169 ED Adequate”
BackgroundVerdú-Rotellar, J. M., Colet, J. C., Domingo, M., Lupón, J., Gómez, M., Molina, L., Casacuberta, J. M., Muñoz, M. Á., González, A. M., & Bruguera, J. (2012) · Revista Española de Cardiología · doi:10.1016/j.recesp.2012.01.019 · Cited by 40 · cited 1×
“NT-proBNP Verdù et al.(33) Diagnostic accuracy 220 Primary care Adequate”
BackgroundEvaluation of a Bedside Whole‐blood Rapid Troponin T Assay in the Emergency Department
Rapid Evaluation by Assay of Cardiac Troponin T (REACTT) Investigators Study Group (1997) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1997.tb03672.x · Cited by 39 · cited 1×
“TnI, CK-MB, Myo Baxter et al.(112) Prospective 721 ED Adequate”
BackgroundKutz, A., Hausfater, P., Oppert, M., Alan, M., Grolimund, E., Gast, C., Alonso, C., Wissmann, C., Kuehn, C., Bernard, M., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0437 · Cited by 38 · cited 1×
“PCT Kutz et al.(70) Diagnostic accuracy 303 Not defined Adequate”
BackgroundNilsson, S., Andersson, P. O., Borgqúist, L., Grodzinsky, E., Janzon, M., Kvick, M., Landberg, E., Nilsson, H., & Karlsson, J. (2013) · International Journal of Family Medicine · doi:10.1155/2013/532093 · Cited by 37 · cited 3×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundMethodA Systematic Review of Emergency Department Point-of-Care Cardiac Markers and Efficiency Measures
Storrow, A. B., Lyon, J. A., Porter, M. W., Zhou, C., Han, J. H., & Lindsell, C. J. (2009) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0b013e3181b316b9 · Cited by 36 · cited 1×
“Our analysis confirms that POCT for cardiac markers does not seem to significantly improve the clinical outcomes, as concluded by a previous systematic review.(125) The usefulness of POCT should be strongly associated with the requirement of a technology able to provide appropriate results together with optimal analyt…”
BackgroundProviding Rapid Out of Hospital Acute Cardiovascular Treatment 4 (PROACT‐4)
Ezekowitz, J. A., Welsh, R. C., Weiss, D., Chan, M. C. Y., Keeble, W., Khadour, F., Sharma, S., Tymchak, W. J., Sookram, S., Brass, N. S., et al. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.115.002859 · Cited by 36 · cited 3×
“TnI Ezekowitz et al.(93) RCT 601 ED Adequate”
BackgroundResultBerardinis, B. D., Gaggin, H. K., Magrini, L., Belcher, A. M., Zancla, B., Femia, A., Simon, M. L., Motiwala, S. R., Bhardwaj, A., Parry, B. A., et al. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0191 · Cited by 35 · cited 1×
“Cross-sectional 414 Primary care Unclear NGAL, BNP, NT-proBNP De Berardinis et al.(65) Prospective 101 ED Adequate”
BackgroundMinnaard, M. C., van de Pol, A. C., de Groot, J. A. H., de Wit, N. J., Hopstaken, R., van Delft, S., Goossens, H., Ieven, M. M., Lammens, C., Little, P. S., et al. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2015.1006136 · Cited by 34 · cited 1×
“CRP Minnaard et al.(55) Diagnostic accuracy 200 Primary care Adequate”
BackgroundAldous, S. J., Richards, M., George, P. M., Cullen, L., Parsonage, W. A., Flaws, D., Florkowski, C. M., Troughton, R. W., O’Sullivan, J. W., Reid, C. M., et al. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.09.026 · Cited by 33 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundLee-Lewandrowski, E., Januzzi, J. L., Grisson, R. D., Mohammed, A. A., Lewandrowski, G., & Lewandrowski, K. B. (2011) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2010-0112-oa.1 · Cited by 31
Lee-Lewandrowski, E., Januzzi, J. L., Green, S. M., Tannous, B. A., Wu, A. H. B., Smith, A. A., Wong, A., Murakami, M. M., Kaczmarek, J. M., Apple, F. S., et al. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.07.015 · Cited by 31 · cited 1×
“NT-proBNP Lee-Lewandrowski et al.(24) Comparative 606 ED Adequate”
BackgroundHamilton, A. J., Swales, L. A., Neill, J., Murphy, J. C., Darragh, K., Rocke, L. G., & Adgey, J. A. (2008) · European Journal of Emergency Medicine · doi:10.1097/mej.0b013e3282aa4045 · Cited by 30 · cited 3×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
Backgroundter Avest, E., Visser, A., Reitsma, B., Breedveld, R., & Wolthuis, A. M. (2015) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000000225 · Cited by 30 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundPoint-of-care C-reactive protein testing in febrile children in general practice
Monteny, M., ten Brinke, M. H., van Brakel, J., de Rijke, Y. B., & Berger, M. Y. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.270 · Cited by 29 · cited 1×
“CRP Monteny et al.(56) Cross-sectional 76 Paediatric Adequate”
BackgroundLindström, J., Nordeman, L., & Hagström, B. (2015) · Scandinavian Journal of Primary Health Care · doi:10.3109/02813432.2015.1114348 · Cited by 29 · cited 1×
“CRP Lindström et al.(50) Observational 340 Primary care Adequate”
BackgroundMarcus, N., Mor, M., Amir, L., Mimouni, M., & Waisman, Y. (2008) · European Journal of Emergency Medicine · doi:10.1097/mej.0b013e3282f12f52 · Cited by 28 · cited 1×
“CRP Marcus et al.(52) Prospective 50 ED Adequate”
BackgroundMulticentre evaluation of a new point-of-care test for the determination of NT-proBNP in whole blood
Zugck, C., Nelles, M., Katus, H. A., Collinson, P. O., Gaze, D. C., Dikkeschei, B. D., Gurr, E., Hayen, W., Haass, M., Hechler, C., et al. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.215 · Cited by 28 · cited 1×
“NT-proBNP Zugck et al.(39) Comparative 674 Not specified Adequate”
BackgroundHollmén, M., Kyllönen, L., Merenmies, J. M., & Salmela, K. T. (2014) · BMC Nephrology · doi:10.1186/1471-2369-15-123 · Cited by 28 · cited 1×
“NGAL Hollmen et al.(68) Comparative 176 Dialysis Adequate”
MethodMarcus, N., Mor, M., Amir, L., Mimouni, M., & Waisman, Y. (2007) · Pediatric Emergency Care · doi:10.1097/pec.0b013e31814a6a52 · Cited by 27 · cited 1×
“CRP Marcus et al.(51) Prospective 44 Paediatric Unclear”
BackgroundSerio, F. D., Amodio, G., Varraso, L., Campaniello, M., Coluccia, P., Trerotoli, P., Antonelli, G., & Pansini, N. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.035 · Cited by 26 · cited 1×
“TnI Di Serio et al.(91) Comparative 85 Not defined Adequate”
BackgroundCollinson, P. O., Jørgensen, B., Sylvén, C., Haass, M., Chwallek, F., Katus, H. A., Müller-Bardorff, M., Derhaschnig, U., Hirschl, M. M., & Zerback, R. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00428-4 · Cited by 26 · cited 1×
“TnT Collinson et al.(86) Comparative 319 Not defined Unclear”
BackgroundEstimating the clinical impact of bringing a multimarker cardiac panel to the bedside in the ED
Birkhahn, R., Haines, E. J., Wen, W., Reddy, L. L., Briggs, W. M., & Datillo, P. A. (2010) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2009.12.007 · Cited by 26 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundRapid bedside measurement of brain natriuretic peptide in patients with chronic heart failure
Tjeerdsma, G., de Boer, R. A., Boomsma, F., van den Berg, M. P., Pinto, Y. M., & van Veldhuisen, D. J. (2002) · International Journal of Cardiology · doi:10.1016/s0167-5273(02)00409-6 · Cited by 25 · cited 1×
“BNP Tjeerdsma et al.(32) Comparative 78 Clinic Adequate”
BackgroundMogensen, C. B., Borch, A., & Brandslund, I. (2011) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/1757-7241-19-49 · Cited by 25 · cited 1×
“Thus, for patients with suspected deep venous thrombosis, acute coronary syndrome or acute appendicitis, POCT significantly reduced TAT but was proven to have a limited effect on time to action.(126,127) Furthermore, some authors showed as the usefulness of POCT in faster decision-making, influencing treatment and fur…”
BackgroundSomma, S. D., Zampini, G., Vetrone, F., Soto‐Ruiz, K. M., Magrini, L., Cardelli, P., Ronco, C., Maisel, A. S., & Peacock, W. F. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0267 · Cited by 24 · cited 1×
“Despite the rapid TAT, early POCT had a lower sensitivity compared with hs-cTn performed in a central laboratory, which is more effective in excluding AMI in patients accessing ED with higher accuracy.(124) Our analysis confirms that POCT for cardiac markers does not seem to significantly improve the clinical outcomes…”
MethodEvidence-based point-of-care tests and device designs for disaster preparedness
Brock, T. K., Mecozzi, D. M., Sumner, S. L., & Kost, G. J. (2010) · American Journal of Disaster Medicine · doi:10.5055/ajdm.2010.0034 · Cited by 23 · cited 1×
“Furthermore, some authors showed as the usefulness of POCT in faster decision-making, influencing treatment and further care,(128) supporting clinical decisions and stratifying patients,(5) but only in specific environments when access to care is limited or in case of environmental disasters.(129,130) The literature e…”
BackgroundZaninotto, M., Mion, M. M., Serio, F. D., Caputo, M., Ottomano, C., & Plebani, M. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.222 · Cited by 22
Andersson, P. O., Karlsson, J., Landberg, E., Festin, K., & Nilsson, S. (2015) · BMC Research Notes · doi:10.1186/s13104-015-1174-0 · Cited by 21 · cited 1×
“hs cTnT Andersson et al.(79) Observational 115 Not defined Adequate”
BackgroundFarrag, T. Y., Weinberger, P., Seybt, M. W., & Terris, D. J. (2011) · American Journal of Otolaryngology · doi:10.1016/j.amjoto.2010.11.013 · Cited by 21 · cited 2×
“Most evaluated studies simply evaluated the decrease of TAT, suggesting that the decrease of time elapsed from test request and release of results could produce an advantage to patients’ management.(5,6,17,74,77,87,89,93,95) Available studies evaluated scientific dimensions only, which are considered surrogate outcome…”
BackgroundResultGoldmann, B. U., Langenbrink, L., Matschuck, G., Heeschen, C., Kolbe-Busch, S., Niederau, C. M., Katz, N. R., Wenserit, C., Lestin, H.-G., Brinker, K., et al. (2004) · PubMed · Cited by 20
Shah, K., Terracciano, G. J., Jiang, K. W., et al. (2010) · PubMed · Cited by 20
Estimating the clinical impact of bringing a multimarker cardiac panel to the bedside in the ED
Birkhahn, R., Haines, E. J., Wen, W., Reddy, L., Briggs, W. M., & Datillo, P. A. (2011) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2011.01.003 · Cited by 20
Shah, K., Terracciano, G. J., Jiang, K. W., Maisel, A. S., & Fitzgerald, R. L. (2010) · PubMed Central · Cited by 20
Ordóñez‐Llanos, J., Santaló‐Bel, M., Mercé-Muntañola, J., Collinson, P. O., Gaze, D. C., Haass, M., Katus, H. A., Chwallek, F., Hirschl, M. M., Derhaschnig, U., et al. (2005) · Clinica Chimica Acta · doi:10.1016/j.cca.2005.07.035 · Cited by 19 · cited 1×
“TnI, CK-MB, Myo Ordóñez-Llanos et al.(110) Prospective 1410 ED Unclear”
BackgroundHowell, E., Sen, S., Palmieri, T. L., Godwin, Z. R., Bockhold, J. C., Greenhalgh, D., & Tran, N. K. (2014) · Journal of Burn Care & Research · doi:10.1097/bcr.0000000000000098 · Cited by 19 · cited 3×
“BNP Howell et al.(17) Observational 15 Intensive care Unclear”
BackgroundMethodResultHjortshøj, S. P., Venge, P., & Ravkilde, J. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.11.015 · Cited by 18 · cited 2×
“In contrast, opinions on patient improvement outcomes were discordant: some authors reported a benefit for patients(78,83) and others concluded that there was no difference.(93,100) Only one study evaluated the diagnostic accuracy of physicians’ decision-making in primary care, reporting sensitivity of 67% and specifi…”
BackgroundResultAlehagen, U., & Janzon, M. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.01.005 · Cited by 18
Yebyo, H. G., Medhanyie, A. A., Spigt, M., & Hopstaken, R. (2016) · npj Primary Care Respiratory Medicine · doi:10.1038/npjpcrm.2015.76 · Cited by 18 · cited 1×
“CRP Yebyo et al.(64) Cross-sectional 414 Primary care Unclear NGAL, BNP, NT-proBNP De Berardinis et al.”
BackgroundGils, C., Ramanathan, R., Breindahl, T., Brokner, M., Christiansen, A. L., Eng, Ø., Hammer, I. J., Herrera, C. B., Jansen, A., Langsjøen, E. C., et al. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2015.1066846 · Cited by 17 · cited 1×
“NT-proBNP Gils et al.(14) Comparative 95 Not specified Unclear BNP, TnI, CK-MB, Myo Hamilton et al.”
BackgroundWu, Z., Zhao, M., He, M., Zeng, H., Tan, F., Li, K., Chen, S., Han, Q., & Wang, Q. (2015) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2015.01.013 · Cited by 17 · cited 1×
“BNP Wu et al.(37) Prospective 172 ED Adequate”
BackgroundCramer, G. E., Kievit, P. C., Brouwer, M. A., de Keijzer, M. H., Luijten, H. E., & Verheugt, F. W. A. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.03.001 · Cited by 16 · cited 2×
“TnT, TnI Cramer et al.(89) Comparative 358 ED Unclear”
ResultRestoring Point‐of‐Care Testing during Parathyroidectomy with a Newer Parathyroid Hormone Assay
Terris, D. J., Weinberger, P., Farrag, T. Y., Seybt, M. W., & Oliver, J. E. (2011) · Otolaryngology · doi:10.1177/0194599811413718 · Cited by 16 · cited 2×
“Most evaluated studies simply evaluated the decrease of TAT, suggesting that the decrease of time elapsed from test request and release of results could produce an advantage to patients’ management.(5,6,17,74,77,87,89,93,95) Available studies evaluated scientific dimensions only, which are considered surrogate outcome…”
BackgroundResultHallani, H., Leung, D. Y., Newland, E. F., & Juergens, C. (2005) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2005.00897.x · Cited by 15 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundPoint‐of‐care testing has a limited effect on time to clinical decision in primary health care
Grodzinsky, E., Wirehn, A. ‐., Fremner, E., Haglund, S., Larsson, L., Persson, L., & Borgqúist, L. (2004) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510410007044 · Cited by 15 · cited 1×
“Thus, for patients with suspected deep venous thrombosis, acute coronary syndrome or acute appendicitis, POCT significantly reduced TAT but was proven to have a limited effect on time to action.(126,127) Furthermore, some authors showed as the usefulness of POCT in faster decision-making, influencing treatment and fur…”
BackgroundSchneider, H. G., Ablitt, P., & Taylor, J. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.04.016 · Cited by 15 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundAsha, S. E., Cooke, A., Walter, E., & Weaver, J. C. (2014) · Emergency Medicine Journal · doi:10.1136/emermed-2014-203958 · Cited by 15 · cited 2×
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
BackgroundLang, N. N., Wong, C. M., Dalzell, J. R., Jansz, S., Leslie, S. J., & Gardner, R. S. (2014) · Biomarkers in Medicine · doi:10.2217/bmm.14.48 · Cited by 14
Evaluation of the Alere NT‐proBNP Test for Point of Care Testing
Khezri, B. S., Carlsson, L. M. S., & Larsson, A. O. (2015) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21853 · Cited by 14 · cited 1×
“NT-proBNP Khezri et al.(18) Comparative 98 Department of Clinical Chemistry Pharm Adequate”
BackgroundComparison of the Diagnostic Characteristics of Two B-Type Natriuretic Peptide Point-of-Care Devices
Ro, R., Thode, H. C., Taylor, M., Gulla, J., Tetrault, E., & Singer, A. J. (2011) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2010.10.025 · Cited by 13 · cited 1×
“BNP Ro et al.(30) Prospective 250 Triage Adequate”
BackgroundAydin, B., Díllí, D., Zenciroğlu, A., Kaya, Ö., Bilaloğlu, E., Okumuş, N., & Beken, S. (2013) · Clinical Laboratory · doi:10.7754/clin.lab.2012.120923 · Cited by 12 · cited 1×
“CRP Aydin et al.(41) Prospective 63 Pediatric Adequate”
BackgroundEvaluating theQuikRead®C-reactive protein test as a point-of-care test
Diar, H. A., Nakwa, F. L., Thomas, R., Libhaber, E. N., & Velaphi, S. (2012) · Paediatrics and International Child Health · doi:10.1179/1465328111y.0000000045 · Cited by 12 · cited 1×
“CRP Diar et al.(46) Prospective 209 Paediatric Adequate”
BackgroundProntera, C., Masotti, S., Franzini, M., Emdin, M., Passino, C., Zucchelli, G. C., & Clerico, A. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0873 · Cited by 11 · cited 1×
“BNP Prontera et al.(28) Comparative 88 Not specified Unclear”
BackgroundDupuy, A., Sebbane, M., Roubille, F., Coste, T., Bargnoux, A. S., Badiou, S., Kuster, N., & Cristol, J. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.09.027 · Cited by 10 · cited 1×
“TnT Dupuy et al.(92) Comparative 68 Emergency and cardiology department Adequate”
BackgroundValidation of a point of care troponin assay in real life emergency department conditions
Loten, C., Attia, J., Hullick, C., Marley, J. E., & McElduff, P. (2009) · Emergency Medicine Australasia · doi:10.1111/j.1742-6723.2009.01198.x · Cited by 10 · cited 1×
“TnI Loten et al.(102) Observational 332 ED Adequate”
BackgroundIshida, J., Suzuki, T., Aizawa, K., Sawaki, D., & Nagai, R. (2012) · International Heart Journal · doi:10.1536/ihj.53.320 · Cited by 10 · cited 1×
“BNP Ishida et al.(21) Comparative 57 Samples Not specified Unclear”
BackgroundBlick, K. E. (2014) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2013.11.002 · Cited by 9
Lepoutre, T., Rousseau, M., Ahn, S., & Gruson, D. (2013) · Clinical Laboratory · doi:10.7754/clin.lab.2012.120418 · Cited by 8 · cited 1×
“NT-proBNP Lepoutre et al.(25) Comparative 114 Not specified Adequate”
BackgroundKosowsky, J. M., Weiner, C., Aronson, A. A., & Morrissey, J. (2006) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2005.10.001 · Cited by 8 · cited 1×
“BNP Kosowsky et al.(20) Observational 88 ED Unclear”
BackgroundPapa, F., Rongioletti, M. C. A., Majolini, M., Collegiani, V., Vaccarella, C., Notarmuzi, M., Cortesi, M., Pasqualetti, P., Cicchese, M., Agostino, R., et al. (2012) · Clinical Laboratory · doi:10.7754/clin.lab.2011.110628 · Cited by 7 · cited 1×
“CRP Papa et al.(58) Prospective 150 Paediatric Unclear”
BackgroundSiebenhaar, R., Mushholt, P. B., Forst, T. M., Weber, M. M., Maurer, R., & Pfützner, A. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400327 · Cited by 7 · cited 1×
“CRP Siebenhaar et al.(62) Comparative 66 Not defined Adequate”
BackgroundFarsi, D., Pishbin, E., Abbasi, S., Hafezimoghadam, P., Fathi, M., & Zare, M. A. (2012) · European Journal of Emergency Medicine · doi:10.1097/mej.0b013e328351360f · Cited by 5 · cited 1×
“TnI Farsi et al.(94) Prospective 262 ED Adequate”
BackgroundPeters, C. M., Schouwenaars, F. M., Haagsma, E., Evenhuis, H. M., & Echteld, M. A. (2013) · British Journal of General Practice · doi:10.3399/bjgp13x667187 · Cited by 5 · cited 1×
“CRP Peters et al.(59) Cohort 1472 Not defined Adequate”
BackgroundJørgensen, B., Bertsch, T., Bröker, H.-J., Schäfer, M., Chapelle, J.-P., Gadisseur, R., Cowie, M., Dikkeschei, B. D., Gurr, E., Hayen, W., et al. (2012) · PubMed · Cited by 5
Markovic, S., Armbruster, F. P., Dschietzig, T. B., & Köenig, W. (2015) · Clinical Laboratory · doi:10.7754/clin.lab.2015.141108 · Cited by 5 · cited 1×
“CRP Markovic et al.(53) Comparative 104 Not defined Unclear”
BackgroundMonneret, D., Abbes, R. A. B., Omarjee, R., Devilliers, C., Manach, Y. L., Raux, M., Coriat, P., Imbert‐Bismut, F., & Bonnefont‐Rousselot, D. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0231 · Cited by 4 · cited 1×
“hs TnT Monneret et al.(106) Comparative NR Not defined Inadequate”
BackgroundEvaluation of the Meritas® BNP Test for Point-of-Care Testing
Olausson, J., Peterson, C. G. B., Bergström, M., & Larsson, A. O. (2015) · Clinical Laboratory · doi:10.7754/clin.lab.2014.140815 · Cited by 2 · cited 1×
“BNP Olausson et al.(26) Comparative 82 Not specified Adequate”
BackgroundAltinier, S., Zaninotto, M., Mion, M. M., & Plebani, M. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.223 · Cited by 1 · cited 1×
“Few studies have been conducted to evaluate the effect of the results obtained in POCT on clinical outcomes, and, usually indicate the decrease of turn-around-time (TAT) as a critical factor in determining positive effect on patient management.(2) As evaluated in a previous survey, most studies evaluated surrogate out…”
Research works printed but not linked: 11
- Del Ry S, 2001, Clin Chem Lab Med, 39, 446
- Di Somma S, 2015, Clin Chem Lab Med, 43, 507
- Jorgensen B, 2012, Clin Lab, 58, 515
- Prontera C, 2005, Clin Lab, 51, 1274
- Shah K, 2010, West J Emerg Med, 11, 44
- Vogeser M, 2001, Clin Lab, 47, 29
- 10.1067/mhj.2002.125623 · doi:10.1067/mhj.2002.125623 · Paper page
- Papa F, 2012, Clin Lab, 58, 951
- Goldmann BU, 2004, Clin Lab, 50, 1
- Loten C, 2009, EMA, 21, 286
- Monneret D, 2014, Clin Chem Lab Med, 52, e279
Cited by
Acute Stroke Biomarkers: Are We There Yet?
Dagonnier, M., Donnan, G. A., Davis, S. M., Dewey, H. M., & Howells, D. W. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.619721 · Cited by 155
Point-of-care testing: state-of-the art and perspectives
Plebani, M., Nichols, J. H., Luppa, P. B., Greene, D., Sciacovelli, L., Shaw, J., Khan, A. I., Carraro, P., Freckmann, G., Dimech, W., et al. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0675 · Cited by 119
Self-citationGandhi, M., Bacchetti, P., Rodrigues, W. C., Spinelli, M. A., Koss, C. A., Drain, P. K., Baeten, J. M., Mugo, N., Ngure, K., Benet, L. Z., et al. (2018) · EClinicalMedicine · doi:10.1016/j.eclinm.2018.08.004 · Cited by 74
“A rapid lateral flow strip test is likely to be the most cost effective POC test for use in resource-limited settings[16], and we have experience in developing rapid strip LFAs from suitable antibodies, but the POC test still requires packaging and marketing.”
AACC guidance document on management of point-of-care testing
Nichols, J. H., Alter, D., Chen, Y., Isbell, T. S., Jacobs, E., Moore, N., & Shajani-Yi, Z. (2020) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaa059 · Cited by 63
Point-of-Care Troponin Testing during Ambulance Transport to Detect Acute Myocardial Infarction
Stopyra, J. P., Snavely, A. C., Scheidler, J. F., Smith, L. M., Nelson, R. D., Winslow, J. E., Pomper, G. J., Ashburn, N. P., Hendley, N., Riley, R. F., et al. (2020) · Prehospital Emergency Care · doi:10.1080/10903127.2020.1721740 · Cited by 48
Metadata
- Authors
- Pecoraro, V., Banfi, G., Germagnoli, L., & Trenti, T.
- Affiliations
- Mario Negri Institute for Pharmacological Research (IT)
- Vita-Salute San Raffaele University (IT)
- Synlab Italia, Brescia, Italy
- Department of Laboratory Medicine, Clinical Pathology-Toxicology, Ospedale Civile Sant’Agostino Estense, Modena, Italy
- Corresponding author
- Pecoraro, Valentina
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2017-05-15
- Volume
- 54
- Issue
- 4
- Pages
- 420-431
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2583469375
- Cited by
- 17
- References
- 130
- Citations by year
- 2026: 1 · 2024: 3 · 2022: 1 · 2021: 3 · 2020: 4 · 2019: 2 · 2018: 2 · 2017: 1
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of Clinical Biochemistry International Journal of Laboratory Medicine (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università Vita-Salute San Raffaele (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Keywords
- point-of-care testing, immunoassay, patient outcomes, diagnostic accuracy, analytical performance, troponin, brain natriuretic peptide, C-reactive protein, procalcitonin, parathyroid hormone, neutrophil gelatinase-associated lipocalin, antibiotic prescribing, central laboratory comparison, clinical decision-making
- MeSH terms
- Clinical Decision-Making, Point-of-Care Testing, Clinical Studies as Topic, Lipocalin-2, C-Reactive Protein, Calcitonin, Humans, Immunoassay, Laboratories, Hospital, Parathyroid Hormone, Sensitivity and Specificity, Troponin, Treatment Outcome, Natriuretic Peptide, Brain
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.