Performance of Dental Ceramics: Challenges for Improvements
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
The clinical success of modern dental ceramics depends on an array of factors, ranging from initial physical properties of the material itself, to the fabrication and clinical procedures that inevitably damage these brittle materials, and the oral environment. Understanding the influence of these factors on clinical performance has engaged the dental, ceramics, and engineering communities alike. The objective of this review is to first summarize clinical, experimental, and analytic results reported in the recent literature. Additionally, it seeks to address how this new information adds insight into predictive test procedures and reveals challenges for future improvements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GARVIE, R. C., HANNINK, R. H., & PASCOE, R. T. (1975) · Nature · doi:10.1038/258703a0 · Cited by 2,291
State of the art of zirconia for dental applications
Denry, I., & Kelly, J. R. (2008) · Dental Materials · doi:10.1016/j.dental.2007.05.007 · Cited by 2,133
The Tetragonal‐Monoclinic Transformation in Zirconia: Lessons Learned and Future Trends
Chevalier, J., Gremillard, L., Virkar, A. V., & Clarke, D. R. (2009) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2009.03278.x · Cited by 1,609
An overview of zirconia ceramics: Basic properties and clinical applications
Manicone, P. F., Rossi Iommetti, P., & Raffaelli, L. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2007.07.008 · Cited by 1,369
What future for zirconia as a biomaterial?
Chevalier, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.034 · Cited by 1,228
Stabilized zirconia as a structural ceramic: An overview
Kelly, J. R., & Denry, I. (2008) · Dental Materials · doi:10.1016/j.dental.2007.05.005 · Cited by 1,172
A review of dental CAD/CAM: current status and future perspectives from 20 years of experience
MIYAZAKI, T., HOTTA, Y., KUNII, J., KURIYAMA, S., & TAMAKI, Y. (2009) · Dental Materials Journal · doi:10.4012/dmj.28.44 · Cited by 1,070
Guazzato, M., Albakry, M., Ringer, S. P., & Swain, M. V. (2004) · Dental Materials · doi:10.1016/j.dental.2003.05.002 · Cited by 904
Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.
Sailer, I., Fehér, A., Filser, F., Gauckler, L. J., Lüthy, H., & Hämmerle, C. H. F. (2007) · PubMed · Cited by 807
Sailer, I., Pjetursson, B. E., Zwahlen, M., & Hämmerle, C. H. F. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01468.x · Cited by 724
The Clinical Success Of All-Ceramic Restorations
Bona, Á. D., & Kelly, J. R. (2008) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2008.0361 · Cited by 436
Bioceramics and Their Clinical Applications
(2008) · CRC Press eBooks · doi:10.1201/9781439832530 · Cited by 378
Reich, S., Wichmann, M. G., Nkenke, E., & Proeschel, P. (2005) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2004.00197.x · Cited by 364
Damage accumulation and fatigue life of particle-abraded ceramics.
Zhang, Y., Lawn, B. R., Malament, K. A., Thompson, V. P., & Rekow, E. D. (2006) · PubMed · Cited by 328
Self-citationSailer, I., Gottnerb, J., Känel, S., & Hämmerle, C. H.-F. (2009) · PubMed · doi:10.5167/uzh-25315 · Cited by 314
Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results.
Tinschert, J., Schulze, K. A., Natt, G., Latzke, P. M., Heussen, N. M., & Spiekermann, H. (2008) · PubMed · Cited by 301
Slow fracture model based on strained silicate structures
Michalske, T. A., & Bunker, B. C. (1984) · Journal of Applied Physics · doi:10.1063/1.333789 · Cited by 300
Deville, S., Chevalier, J., & Gremillard, L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.021 · Cited by 295
Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs.
Molin, M., & Karlsson, S. L. (2008) · PubMed · Cited by 260
Materials design in the performance of all-ceramic crowns
Lawn, B. R., Pajares, A., Zhang, Y., Deng, Y., Polack, M. A., Lloyd, I. K., Rekow, E. D., & Thompson, V. P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.050 · Cited by 219
Self-citationMarginal and internal fits of fixed dental prostheses zirconia retainers
Beuer, F., Aggstaller, H., Edelhoff, D., Gernet, W., & Sorensen, J. (2009) · Dental Materials · doi:10.1016/j.dental.2008.04.018 · Cited by 199
Flexural strength of veneering ceramics for zirconia
Fischer, J., Stawarczyk, B., & Hämmerle, C. H. F. (2008) · Journal of Dentistry · doi:10.1016/j.jdent.2008.01.017 · Cited by 171
Environmentally Enhanced Fracture of Glass: A Historical Perspective
Freiman, S. W., Wiederhorn, S. M., & Mecholsky, Jr. (2009) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2009.03097.x · Cited by 164
Three-year clinical evaluation of two ceramic crown systems: A preliminary study
Etman, M. K., & Woolford, M. J. (2010) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(10)60010-8 · Cited by 162
Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up.
Schmitt, J., Holst, S., Wichmann, M. G., Reich, S., Göllner, M., & Hamel, J. (2009) · PubMed · Cited by 155
Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs.
von Steyern, P. V., Jönsson, O., & Nilner, K. (2001) · PubMed · Cited by 153
HIP zirconia fixed partial dentures--clinical results after 3 years of clinical service.
Edelhoff, D., Beuer, F., Florian, W., & Johnen, C. (2008) · Quintessence International · Cited by 152
Aboushelib, M. N., Feilzer, A. J., & Kleverlaan, C. J. (2008) · Dental Materials · doi:10.1016/j.dental.2008.09.001 · Cited by 148
Fractographic ceramic failure analysis using the replica technique
Scherrer, S. S., Quinn, J. B., Quinn, G. D., & Wiskott, H. W. A. (2007) · Dental Materials · doi:10.1016/j.dental.2006.12.002 · Cited by 140
A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs.
Olsson, K.-G., Fürst, B., Andersson, B., & Carlsson, G. E. (2003) · PubMed · Cited by 138
Failure analysis of ceramic clinical cases using qualitative fractography.
Scherrer, S. S., Quinn, J. B., Quinn, G., & Kelly (2006) · PubMed · Cited by 134
A systematic review of the clinical performance of CAD/CAM single-tooth restorations.
Wittneben, J., Wright, R. F., Weber, H.-P., & Gallucci, G. O. (2009) · PubMed · Cited by 129
Cyclic fatigue in water of veneer–framework composites for all-ceramic dental bridges
Studart, A. R., Filser, F., Kocher, P., Lüthy, H., & Gauckler, L. J. (2006) · Dental Materials · doi:10.1016/j.dental.2006.01.011 · Cited by 127
Çehreli, M. C., Kökat, A. M., & Akça, K. (2009) · Journal of Applied Oral Science · doi:10.1590/s1678-77572009000100010 · Cited by 124
Damage and Reliability of Y-TZP after Cementation Surface Treatment
Guess, P. C., Zhang, Y., Kim, J.-W., Rekow, E. D., & Thompson, V. P. (2010) · Journal of Dental Research · doi:10.1177/0022034510363253 · Cited by 119
Self-citationKelly, J. R. (2008) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2008.0359 · Cited by 118
Retrospective survival analysis of 261 lithium disilicate crowns in a private general practice.
Valenti, M., & Valenti, A. (2009) · PubMed · Cited by 114
Ten-year outcome of crowns placed within the general dental services in England and Wales
Burke, F. J. T., & Lucarotti, P. S. K. (2009) · Journal of Dentistry · doi:10.1016/j.jdent.2008.03.017 · Cited by 105 · cited 2×
“…gender, age, frequency of treatment, tooth history, recurrent caries, and periodontal factors), and dentist factors (including age, gender, and country of qualification) can all affect survival rates (Burke and Lucarotti, 2009; Malament and Socransky, 2010) – but these are not always reported.”
BackgroundInfluence of the veneering process on the marginal fit of zirconia fixed dental prostheses
Kohorst, P., Brinkmann, H., Dittmer, M. P., Borchers, L., & Stiesch, M. (2010) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2009.02053.x · Cited by 91
Graded Structures for All-ceramic Restorations
Zhang, Y., Chai, H., & Lawn, B. R. (2010) · Journal of Dental Research · doi:10.1177/0022034510363245 · Cited by 89
Self-citationGonzaga, C. C., Yoshimura, H. N., Cesar, P. F., & Miranda, W. G. (2008) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-008-3667-z · Cited by 66
Results of a prospective randomized controlled trial of posterior ZrSiO4‐ceramic crowns
ENCKE, B. S., Heydecke, G., Wolkewitz, M., & Strub, J. R. (2009) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2008.01918.x · Cited by 43
Song, X., Yin, L., Han, Y., & Li, J. (2007) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30915 · Cited by 21
Thompson, V. P., & Rekow, E. D. (2008) · Elsevier eBooks · doi:10.1533/9781845694227.2.518 · Cited by 5
Self-citation
Cited by
Novel Zirconia Materials in Dentistry
Zhang, Y., & Lawn, B. R. (2018) · Journal of Dental Research · doi:10.1177/0022034517737483 · Cited by 998
Self-citationTrends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams
Abduo, J., Lyons, K., & Bennamoun, M. (2014) · International Journal of Dentistry · doi:10.1155/2014/783948 · Cited by 424
Anusavice, K. J. (2012) · Dental Materials · doi:10.1016/j.dental.2011.09.012 · Cited by 261
Nanotechnology in dentistry: Present and future perspectives on dental nanomaterials
Jandt, K. D., & Watts, D. C. (2020) · Dental Materials · doi:10.1016/j.dental.2020.08.006 · Cited by 238
“Significantly enhanced structural reliability through flaw control, damage tolerance [ 85 ] and additive manufacturing [ 86 ] using novel mix ceramic nanocompositions may lead to significant progress in these materials.”
BackgroundJohansson, C., Kmet, G., Rivera, J., Larsson, C., & Vult Von Steyern, P. (2014) · Acta Odontologica Scandinavica · doi:10.3109/00016357.2013.822098 · Cited by 171
“Therefore, when testing a material, it is often best to evaluate clinically shaped restorations under environmental conditions close to those present in the oral cavity and to compare the results with clinical data on the maximum loads that might occur in the oral cavity [5,30,31].”
Background
Metadata
- Authors
- Rekow, E. D., Silva, N. R. F. A., Coelho, P. G., Zhang, Y., Guess, P., & Thompson, V. P.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 2011-01-11
- Volume
- 90
- Issue
- 8
- Pages
- 937-952
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W2158272808
- Cited by
- 453
- References
- 44
- FWCI
- 30.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.