Long-term Stability of Early Implant Placement with Contour Augmentation
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
In this prospective case series study, 20 patients with an implant-borne single crown following early implant placement with simultaneous contour augmentation were followed for 6 years. Clinical, radiologic, and esthetic parameters were assessed. In addition, cone beam computed tomography (CBCT) was used at 6 years to examine the facial bone wall. During the study period, all 20 implants were successfully integrated, and the clinical parameters remained stable over time. Pleasing esthetic outcomes were noted, as assessed by the pink esthetic scores. None of the implants developed mucosal recession of 1 mm or more. The periapical radiographs yielded stable peri-implant bone levels, with a mean DIB of 0.44 mm at 6 years. The CBCT scans showed that all 20 implants had a detectable facial bone wall at 6 years, with a mean thickness of around 1.9 mm. In summary, this prospective case series study demonstrated stable peri-implant hard and soft tissues for all 20 implants, and pleasing esthetic outcomes overall. The follow-up of 6 years confirmed that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration (GBR) was able to establish and maintain a facial bone wall in all 20 patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dimensional ridge alterations following tooth extraction. An experimental study in the dog
Araújo, M. G., & Lindhe, J. (2005) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2005.00642.x · Cited by 1,954
Belser, U. C., Grütter, L., Vailati, F., Bornstein, M. M., Weber, H., & Buser, D. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.080435 · Cited by 738
Self-citationEffective dose range for dental cone beam computed tomography scanners
Pauwels, R., Beinsberger, J., Collaert, B., Theodorakou, C., Rogers, J., Walker, A., Cockmartin, L., Bosmans, H., Jacobs, R., Bogaerts, R., et al. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.11.028 · Cited by 642 · cited 1×
“Today, CBCT technology offers excellent image quality with a clearly reduced radiation dose risk for the patient when compared with dental CTs, in particular when a small 4 x 4-cm field of view is used (Loubele et al., 2009; Pauwels et al., 2012).”
BackgroundHämmerle, C. H. F., Chen, S. T., & Wilson, T. G. (2004) · PubMed · Cited by 609
Clinical and esthetic outcomes of implants placed in postextraction sites.
Chen, S. T., & Buser, D. (2009) · PubMed · Cited by 574
Self-citationChen, S., & Buser, D. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g3.3 · Cited by 525 · cited 1×
“An increased mucosal recession rate of between 20% and 40% was reported in 2 systematic reviews of esthetic complications with immediate implants, when primarily non-platform-switching implants were examined (Chen and Buser, 2009, 2013).”
BackgroundSelf-citationAtieh, M. A., Ibrahim, H. M., & Atieh, A. H. (2010) · Journal of Periodontology · doi:10.1902/jop.2010.100232 · Cited by 369 · cited 1×
“In recent years, several studies have demonstrated good crestal bone stability for such implants (Atieh et al., 2010).”
BackgroundBuser, D., Weber, H., Brägger, U., & Balsiger, C. (1992) · Implant Dentistry · doi:10.1097/00008505-199200130-00016 · Cited by 270 · cited 8×
“, 1991) • Probing depth (PD, in mm; Buser et al., 1991) • Width of keratinized mucosa (KM, in mm; Buser et al.”
BackgroundMethodSelf-citationBornstein, M. M., Schmid, B., Belser, U. C., Lussi, A., & Buser, D. (2005) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01209.x · Cited by 257
Self-citationA 5-year prospective clinical and radiographic study of non-submerged dental implants
Weber, H.-P., Crohin, C. C., & Fiorellini, J. P. (2000) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2000.011002144.x · Cited by 245
Cited by
Chen, S., & Buser, D. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g3.3 · Cited by 525
Self-citationBuser, D., Chappuis, V., Belser, U. C., & Chen, S. (2017) · Periodontology 2000 · doi:10.1111/prd.12170 · Cited by 479
Self-citationOsteoMacs: Key players around bone biomaterials
Miron, R. J., & Bosshardt, D. D. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.12.017 · Cited by 321
Implant placement and loading protocols in partially edentulous patients: A systematic review
Gallucci, G. O., Hamilton, A., Zhou, W., Buser, D., & Chen, S. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13276 · Cited by 288
Self-citationSelection of Collagen Membranes for Bone Regeneration: A Literature Review
Sbricoli, L., Guazzo, R., Annunziata, M., Gobbato, L., Bressan, E., & Nastri, L. (2020) · Materials · doi:10.3390/ma13030786 · Cited by 253
Soft Tissue Alterations in Esthetic Postextraction Sites: A 3-Dimensional Analysis
Chappuis, V., Engel, O., Shahim, K., Reyes, M., Katsaros, C., & Buser, D. (2015) · Journal of Dental Research · doi:10.1177/0022034515592869 · Cited by 187
“Spontaneous soft tissue thickening in thin bone phenotypes may be a contributing factor for favorable esthetic outcomes following guided bone regeneration, as demonstrated in a 6-y prospective study (Buser et al. 2013).”
BackgroundResultSelf-citationBornstein, M. M., Horner, K., & Jacobs, R. (2017) · Periodontology 2000 · doi:10.1111/prd.12161 · Cited by 177
“Cone beam computed tomography imaging is increasingly being used for three-dimensional assessment of bone following ridge preservation (1, 7, 94), sinus floor elevation (53, 93, 106, 143) and implant placement with simultaneous bone augmentation (23, 31, 77, 83) or staged procedures following block grafts (97, 98, 129…”
MethodSelf-citationThe etiology of hard‐ and soft‐tissue deficiencies at dental implants: A narrative review
Hämmerle, C. H. F., & Tarnow, D. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0810 · Cited by 164
Reliability of periodontal diagnostic tools for monitoring peri‐implant health and disease
Coli, P., Christiaens, V., Sennerby, L., & Bruyn, H. D. (2017) · Periodontology 2000 · doi:10.1111/prd.12162 · Cited by 134
Metadata
- Authors
- Buser, D., Chappuis, V., Kuchler, U., Bornstein, M. M., Wittneben, J. G., Buser, R., Cavusoglu, Y., & Belser, U. C.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 2013-10-24
- Volume
- 92
- Issue
- 12_suppl
- Pages
- 176S-182S
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W1966048555
- Cited by
- 212
- References
- 22
- FWCI
- 22.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.