The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites
Abstract
Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design–computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks—especially high temperature (HT) and, most of all, high temperature–high pressure (HT-HP)—are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks—particularly experimental PICNs—can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as “no prep” treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial need to conduct clinical studies. Last, manufacturers should provide more complete information regarding their product polymerization process, microstructure, and composition, which significantly influence CAD-CAM material properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estrogenicity of resin-based composites and sealants used in dentistry.
Olea, N., Pulgar, R., Pérez, P., Olea-Serrano, F., Rivas, A., Novillo-Fertrell, A., Pedraza, V, Soto, A. M., & Sonnenschein, C. (1996) · Environmental Health Perspectives · doi:10.1289/ehp.96104298 · Cited by 1,041
Sideridou, I., Tserki, V., & Papanastasiou, G. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00308-8 · Cited by 800
Longevity of Posterior Composite Restorations: A Systematic Review and Meta-analysis
Opdam, N. J. M., van de Sande, F. H., Bronkhorst, E., Cenci, M. S., Bottenberg, P., Pallesen, U., Gaengler, P., Lindberg, A., Huysmans, M. C. D. N. J. M., & van Dijken, J. W. (2014) · Journal of Dental Research · doi:10.1177/0022034514544217 · Cited by 725
Elution of leachable components from composites
FERRACANE, J. L. (1994) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1994.tb01158.x · Cited by 714
Manhart, J., Chen, H., Hamm, G., & Hickel, R. (2004) · PubMed · Cited by 656
Mechanical properties of resin-ceramic CAD/CAM restorative materials
Awada, A., & Nathanson, D. (2015) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.04.016 · Cited by 581
Progress in dimethacrylate-based dental composite technology and curing efficiency
Leprince, J. G., Palin, W. M., Hadis, M. A., Devaux, J., & Leloup, G. (2013) · Dental Materials · doi:10.1016/j.dental.2012.11.005 · Cited by 534
Emerging Ceramic-based Materials for Dentistry
Denry, I., & Kelly, J. R. (2014) · Journal of Dental Research · doi:10.1177/0022034514553627 · Cited by 464
Wear and Marginal Breakdown of Composites with Various Degrees of Cure
Ferracane, J. L., Mitchem, J. C., Condon, J. R., & Todd, R. (1997) · Journal of Dental Research · doi:10.1177/00220345970760081401 · Cited by 456
Mörmann, W. H., Stawarczyk, B., Ender, A., Sener, B., Attin, T., & Mehl, A. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.01.003 · Cited by 342
Materials for chairside CAD/CAM–produced restorations
Giordano, R. (2006) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2006.0397 · Cited by 321
Krifka, S., Spagnuolo, G., Schmalz, G., & Schweikl, H. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.019 · Cited by 289
Stawarczyk, B., Liebermann, A., Eichberger, M., & Güth, J.-F. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.10.004 · Cited by 279
Polymerization stress-is it clinically meaningful
Ferracane, J. L., & Hilton, T. J. (2016) · Dental Materials · doi:10.1016/j.dental.2015.06.020 · Cited by 236
Guidance on posterior resin composites: Academy of Operative Dentistry - European Section
Lynch, C. D., Opdam, N. J., Hickel, R., Brunton, P. A., Gurgan, S., Kakaboura, A., Shearer, A. C., Vanherle, G., & Wilson, N. H. F. (2014) · Journal of Dentistry · doi:10.1016/j.jdent.2014.01.009 · Cited by 228
Molecular Toxicology of Substances Released from Resin–Based Dental Restorative Materials
Bakopoulou, A., Papadopoulos, T., & Garefis, P. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10093861 · Cited by 212
Degree of conversion of composites measured by DTA and FTIR
Imazato, S., McCabe, J. F., Tarumi, H., Ehara, A., & Ebisu, S. (2001) · Dental Materials · doi:10.1016/s0109-5641(00)00066-x · Cited by 206
BisGMA/TEGDMA ratio and filler content effects on shrinkage stress
Gonçalves, F., Azevedo, C. L. N., Ferracane, J. L., & Braga, R. R. (2011) · Dental Materials · doi:10.1016/j.dental.2011.01.007 · Cited by 185
Interpenetrating network ceramic-resin composite dental restorative materials
Swain, M. V., Coldea, A., Bilkhair, A., & Guess, P. C. (2016) · Dental Materials · doi:10.1016/j.dental.2015.09.009 · Cited by 170
Kingman, A., Hyman, J. J., Masten, S. A., Jayaram, B., Smith, C. S., Eichmiller, F. C., Arnold, M. C., Wong, P. A., Schaeffer, J. M., Solanki, S., et al. (2012) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2012.0090 · Cited by 141
Influence of CAD/CAM tool and material on tool wear and roughness of dental prostheses after milling
Lebon, N., Tapie, L., Vennat, E., et al. (2015) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.12.021 · Cited by 128
Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network
Albero, A. A., Pascual, A., Camps, I., et al. (2015) · Journal of Clinical and Experimental Dentistry · doi:10.4317/jced.52521 · Cited by 126
Damage tolerance of indirect restorative materials (including PICN) after simulated bur adjustments
Coldea, A., Fischer, J., Swain, M. V., et al. (2015) · Dental Materials · doi:10.1016/j.dental.2015.03.007 · Cited by 107
Clinical efficacy of composite versus ceramic inlays and onlays: A systematic review
Chabouis, H. F., Smaïl‐Faugeron, V., & Attal, J. (2013) · Dental Materials · doi:10.1016/j.dental.2013.09.009 · Cited by 101
Petrini, M., Ferrante, M., & Su, B. (2013) · Dental Materials · doi:10.1016/j.dental.2012.12.004 · Cited by 90
Effect of temperature on composite polymerization stress and degree of conversion
Calheiros, F. C., Daronch, M., Rueggeberg, F. A., et al. (2014) · Dental Materials · doi:10.1016/j.dental.2014.02.024 · Cited by 80
Randomized Control Trial of Composite Cuspal Restorations
Fennis, W. M. M., Kuijs, R. H., Roeters, F. J. M., Creugers, N. H. J., & Kreulen, C. M. (2013) · Journal of Dental Research · doi:10.1177/0022034513510946 · Cited by 64
A pilot study of a simple photon migration model for predicting depth of cure in dental composite
Chen, Y.-C., Ferracane, J. L., & Prahl, S. A. (2005) · Dental Materials · doi:10.1016/j.dental.2005.05.002 · Cited by 63
Lin‐Gibson, S., Sung, L., Forster, A. M., et al. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.01.043 · Cited by 47
Cited by
CAD/CAM Ceramic Restorative Materials for Natural Teeth
Spitznagel, F. A., Boldt, J., & Gierthmuehlen, P. C. (2018) · Journal of Dental Research · doi:10.1177/0022034518779759 · Cited by 429
Metadata
- Authors
- Mainjot, A. K., Dupont, N. M., Oudkerk, J. C., Dewael, T. Y., & Sadoun, M. J.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 2016-03-01
- Volume
- 95
- Issue
- 5
- Pages
- 487-495
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W2329083179
- Cited by
- 343
- References
- 29
- FWCI
- 34.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.