The DOI matches its Crossref record.
Affinity Imaging of Red Blood Cells Using an Atomic Force Microscope
Open accessAbstract
SUMMARY We used an atomic force microscope (AFM) to produce an image of a mixed layer of group A and O red blood cells with a contrast based only on the measured strength of a specific receptor-ligand pair. The image was obtained by measuring and plotting for each image pixel the adhesion force between the mixed RBC layer and the AFM tip functionalized with Helix pomatia lectin. The high specificity of that lectin for the N-acetylgalactosamine-terminated glycolipids present in the membrane of group A RBCs enabled us to discriminate between the two cell populations and to produce an image based on affinity contrast. The rupture force of the adhesion events leading to the image formation were quantitatively analyzed and compared to rupture forces measured with the same AFM tip on N-acetylgalactosamine tethered to agarose beads. The mean rupture force was found to be 65 pN when measured on the group A RBCs and 35 pN on the agarose beads. These results show that the adhesion, mediated by only a few receptor-ligand pairs, produces sufficient contrast for the affinity image formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Indentation and Adhesive Probing of a Cell Membrane with AFM: Theoretical Model and Experiments
Sen, S., Subramanian, S., & Discher, D. E. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.063826 · Cited by 304
Müller, D. J., Dumitru, A. C., Lo Giudice, C., Gaub, H. E., Hinterdorfer, P., Hummer, G., De Yoreo, J. J., Dufrêne, Y. F., & Alsteens, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00617 · Cited by 259
Self-citationSample preparation procedures for biological atomic force microscopy
EL KIRAT, K., BURTON, I., DUPRES, V., & DUFRENE, Y. F. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01480.x · Cited by 130
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51
Metadata
- Authors
- Grandbois, M., Dettmann, W., Benoit, M., & Gaub, H. E.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 2000-05
- Volume
- 48
- Issue
- 5
- Pages
- 719-724
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2111937104
- Cited by
- 207
- References
- 0
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Affinity Imaging of Red Blood Cells Using an Atomic Force Microscope. https://app.cochat.ai/papers/10.1177/002215540004800516
- The paper
- Grandbois, M., Dettmann, W., Benoit, M., & Gaub, H. E. (2000). Affinity Imaging of Red Blood Cells Using an Atomic Force Microscope. Journal of Histochemistry & Cytochemistry. https://doi.org/10.1177/002215540004800516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.