Color Subtractive–Computer-assisted Image Analysis for Quantification of Cutaneous Nerves in a Diabetic Mouse Model
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Immunohistochemistry (IHC) is a valuable tool for labeling structures in tissue samples. Quantification of immunolabeled structures using traditional approaches has proved to be difficult. Manual counts of IHC-stained structures are inherently biased, require multiple observers, and generate qualitative data. Stereological methods provide accurate quantification but are complex and labor-intensive when staining must be compared among large numbers of samples. In an effort to quickly, objectively, and reproducibly quantify cutaneous innervation in a large number of counterstained tissue sections, we developed a color subtractive–computer-assisted image analysis (CS–CAIA) system. To develop and test the CS–CAIA method, tissue sections of diabetic (db/db) mouse skin and their wild-type (db/–) littermates were stained by IHC for the neural marker PGP 9.5. The brown-red PGP 9.5 peroxidase stain was colorimetrically isolated through a scripted process of color background removal. The remaining stain was thresholded and binarized for computer determination of nerve profile counts (number of stained regions), area fraction (total area of nerve profiles per unit area of tissue), and area density (total number of nerve profiles per unit area of tissue). Using CS–CAIA, epidermal nerve profile counts, area fraction, and area density were significantly lower in db/db compared to db/– mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stereology: the fast lane between neuroanatomy and brain function or still only a tightrope?
Gundersen, H. J. G. (1992) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1992.tb05032.x · Cited by 81
Cited by
Macrophage Dysfunction Impairs Resolution of Inflammation in the Wounds of Diabetic Mice
Khanna, S., Biswas, S., Shang, Y., Collard, E., Azad, A., Kauh, C., Bhasker, V., Gordillo, G. M., Sen, C. K., & Roy, S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009539 · Cited by 694
“Quantification was performed employing a Image processing tool kit (Adobe Photoshop) software that utilizes a color subtractive process [76].”
MethodImmunohistochemistry as an Important Tool in Biomarkers Detection and Clinical Practice
De Matos, L. L., Trufelli, D. C., De Matos, M. G. L., & Da Silva Pinhal, M. A. (2010) · Biomarker Insights · doi:10.4137/bmi.s2185 · Cited by 437
Animal models of neuropathic pain
Jaggi, A. S., Jain, V., & Singh, N. (2011) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2009.00801.x · Cited by 387
Biswas, S., Roy, S., Banerjee, J., Hussain, S.-R. A., Khanna, S., Meenakshisundaram, G., Kuppusamy, P., Friedman, A., & Sen, C. K. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001653107 · Cited by 272
Automated analysis of images for molecular quantification in immunohistochemistry
Guirado, R., Carceller, H., Castillo-Gómez, E., Castrén, E., & Nacher, J. (2018) · Heliyon · doi:10.1016/j.heliyon.2018.e00669 · Cited by 63
Metadata
- Authors
- Underwood, R. A., Gibran, N. S., Muffley, L. A., Usui, M. L., & Olerud, J. E.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 2001-10
- Volume
- 49
- Issue
- 10
- Pages
- 1285-1291
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2168768991
- Cited by
- 56
- References
- 1
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Color Subtractive–Computer-assisted Image Analysis for Quantification of Cutaneous Nerves in a Diabetic Mouse Model. https://app.cochat.ai/papers/10.1177/002215540104901011
- The paper
- Underwood, R. A., Gibran, N. S., Muffley, L. A., Usui, M. L., & Olerud, J. E. (2001). Color Subtractive–Computer-assisted Image Analysis for Quantification of Cutaneous Nerves in a Diabetic Mouse Model. Journal of Histochemistry & Cytochemistry. https://doi.org/10.1177/002215540104901011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.