The DOI matches its Crossref record; 55 of the 56 references it cites were found in a registry or an index.
The Measurement of Energy Expenditure
Abstract
Proper nutrition support depends upon the clinician's ability to estimate the patient's energy expenditure. The accuracy of estimation is inversely proportional to the severity of the patient's illness. This fact has spurred academic and industry groups to pursue the measurement of energy expenditure. Harris and Benedict used indirect calorimetry to develop their now-famous equation nearly 100 years ago. The concept of indirect calorimetry is simple; if you know the concentration of inspired gases and expired gases, along with the flow, you can determine the amount of a gas consumed or produced. The complexity and expense of indirect calorimeters suggest that this simple concept is technically challenging. Because we desire to know the energy expenditure of the most critically ill patients, indirect calorimetry is further confounded by the presence of oxygen and mechanical ventilation. This paper will discuss the myriad of variables and obstacles that complicate the measurement of energy expenditure and will suggest methods to avoid or overcome them.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Energy requirements in polymorbid medical inpatients can be estimated using indirect calorimetry (IC), a published prediction equation or a weight-based formula, although the accuracy of prediction equations in this population is low.”
From ESPEN guideline on nutritional support for polymorbid medical inpatients (2023) · cites this paper as [62]
Citations
Cites
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,688
Measurement of gas exchange in intensive care
Takala, J. A., Keinänen, O., Väisänen, P., & Kari, A. (1989) · Critical Care Medicine · doi:10.1097/00003246-198910000-00015 · Cited by 302
Effect of Routine Intensive Care Interactions on Metabolic Rate
Weissman, C., Kemper, M., Damask, M. C., ASKANAZI, J., Hyman, A. I., & Kinney, J. M. (1984) · CHEST Journal · doi:10.1378/chest.86.6.815 · Cited by 195
Jéquier, E., & Felber, J.-P. (1987) · Baillière's Clinical Endocrinology and Metabolism · doi:10.1016/s0950-351x(87)80011-3 · Cited by 191
Gas Stores of the Body and the Unsteady State
Farhi, L. E., & Rahn, H. (1955) · Journal of Applied Physiology · doi:10.1152/jappl.1955.7.5.472 · Cited by 189
Analysis of error in the determination of respiratory gas exchange at varying FIO2
Ultman, J. S., & Bursztein, S. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.50.1.210 · Cited by 145
Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients
Tissot, S., Delafosse, B. X., Bertrand, O., Bouffard, Y., Viale, J. P., & Annat, G. J. (1995) · Intensive Care Medicine · doi:10.1007/bf01726538 · Cited by 120
A Validation and Comparison Study of Two Metabolic Monitors
Phang, P. T., Rich, T., & Ronco, J. J. (1990) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607190014003259 · Cited by 108
Evaluation of metabolic measuring instruments for use in critically ill patients
Makita, K., NUNN, J. F., & Royston, B. (1990) · Critical Care Medicine · doi:10.1097/00003246-199006000-00013 · Cited by 107
A new handheld device for measuring resting metabolic rate and oxygen consumption
Nieman, D. C., TRONE, G. A., & Austin, M. D. (2003) · Journal of the American Dietetic Association · doi:10.1053/jada.2003.50116 · Cited by 104
Research works printed but not linked: 11
- Harris JA, 1919, Standard Basal Metabolism Constants for Physiologists and Clinicians: A Biometric Study of Basal Metabolism in Man, 223
- Halmagyi DFJ, 1975, Metabolic rate in active respiratoryfailure complicating sepsis, Surgery., 77, 492
- Norton AC, 1979, Accuracy in pulmonary measurement, Respir Care., 24, 131
- Branson RD, 1990, The measurement of energy expenditure: instrumentation, practical considerations and clinical application, Respir Care., 35, 640
- Branson RD, 1992, A simple method for stabilizinginspired oxygen concentration during metabolic measurements [abstract], JPEN J Parenter Enteral Nutr, 16, 33S
- Dickerson RN, 1995, Asimple technique to reduce ventilator dependent errors in oxygen consumptionmeasurements, Nutrition, 11, 145
- Head CA, 1985, A valvesystem for the accurate measurement of energy expenditure in mechanicallyventilated patients, Respir Care., 30, 969
- Kemper MS, 1989, Problems in Respiratory Care: Nutrition and Respiratory Disease, 479
- Fiser RT, 1997, Isolation valveincreases work of breathing in a mechanically ventilated pediatric animalmodel, Respir Care., 42, 688
- Branson RD, 1988, A laboratoryevaluation of the Biergy VVR calorimeter, Respir Care., 33, 341
- Cunnigham KF, 1994, Appropriateinterpretation of indirect calorimetry for determining energy expenditure inintensive care units, Am J Surg., 167, 54
Cited by
Sorted by citations
Items 101–111 of 111
Indirect calorimetry in the ICU
Nates, J. L., & Tajchman, S. K. (2016) · doi:10.1093/med/9780199600830.003.0205
Almeida, A. E. R. (2010) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.5.2010.tde-01022011-140229
Nieuwenhuizen, A. G., & van Schothorst, E. M. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-1851-0
Singer, P., & Rieck, J. (2023) · Medicina · doi:10.56050/01205498.2229
Nutrition in the Neurocritically Ill Patient
Overholt, B. L., & Badjatia, N. (2024) · Springer eBooks · doi:10.1007/978-3-031-62224-3_24
Gudmundstuen, A. M., Iversen, P. O., Pesonen, M., Hjermstad, M. J., Bye, A., Tjønnfjord, G. E., & Skaarud, K. J. (2025) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2025.09.027
Shinozaki, K., Yu, P.-J., Zhou, Q., Cassiere, H. A., John, S., Rolston, D. M., Garg, N., Li, T., Johnson, J., Saeki, K., et al. (2023) · Figshare · doi:10.6084/m9.figshare.24312928
Gas Sensing Technologies and Algorithms for Measurement of Energy Expenditure in Humans: A Review
Shi, Y., & Guan, X. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3651626
Matsuura, H., Deguchi, K., & Iizuka, K. (2026) · Nutrients · doi:10.3390/nu18162743
Sathik, N. R., Ghose, S., Lussier, N. H., Vitale, V. S., Keller, G. L., Lussier, J., Ghazoul, A., Bunchman, T. E., Kakajiwala, A., Raimer, P., et al. (2026) · Journal of critical care · doi:10.1016/j.jcrc.2026.155711
Höchli, A., & Schuepbach, R. A. (2026) · BMJ Nutrition Prevention & Health · doi:10.1136/bmjnph-2026-001590
Metadata
- Authors
- Branson, R. D., & Johannigman, J. A.
- Affiliations
- University of Cincinnati (US)
- Corresponding author
- Branson, Richard D.
- ORCID
- Branson, Richard D.
- Venue
- Nutrition in Clinical Practice
- Publisher
- Wiley
- Published
- 2004-12
- Volume
- 19
- Issue
- 6
- Pages
- 622-636
- ISSN
- 0884-5336 (ISSN-L)
- 1941-2452
- OpenAlex
- W2033421301
- Cited by
- 111
- References
- 56
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 3 · 2023: 13 · 2022: 4 · 2021: 5 · 2020: 7 · 2019: 8 · 2018: 6 · 2017: 9 · 2016: 5 · 2015: 6 · 2014: 2 · 2013: 7 · 2012: 3
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Nutrition in Clinical Practice (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Nursing › Nutrition and Dietetics › Clinical Nutrition and Gastroenterology
- Health Sciences › Medicine › Physiology (medical) › Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Keywords
- energy expenditure, indirect calorimetry, Harris-Benedict equation, critically ill patients, mechanical ventilation, oxygen consumption, nutritional support
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review