Placement of nasoenteral feeding tubes using external magnetic guidance
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Enteral feeding is preferred over parenteral methods, and feeding into the duodenum is preferred over gastric feeding in certain groups of critically ill patients. However, with current techniques, feeding tubes often coil in the stomach, exposing patients to the risk of aspiration. This study investigated whether a nasoenteral feeding tube can be guided beyond the pyloric sphincter, using external magnetic guidance. METHODS: This is a case series of 288 critically ill patients who needed placement of an enteral feeding tube, carried out in the intensive care units and wards of a university‐affiliated community hospital. A 12‐French polyurethane nasoduodenal feeding tube was modified by placing a small magnet in the distal tip. After inserting the tube through the nares into the esophagus, an external magnet was used to draw the tube tip beyond the pyloric sphincter and further into the duodenum or jejunum. Placement was verified by plain abdominal x‐ray, and the depth of insertion (stomach, proximal duodenum, distal duodenum, or jejunum) was recorded. RESULTS: Three hundred twenty‐nine intubations were performed in 288 patients (mean procedure time 15 minutes). In 293 cases (89.1%), the tube was placed beyond the pyloric sphincter. In 139 insertions (42.2%), the tube tip was in the distal portion of the duodenum or the jejunum. There were no significant complications. CONCLUSIONS: This case series demonstrates that external magnetic guidance achieves transpyloric placement of an enteral feeding tube in 89.1% of cases. This reliable bedside technique is superior to other methods described in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Practical Approach to Paediatric Enteral Nutrition: A Comment by the ESPGHAN Committee on Nutrition
ESPGHAN Committee on Nutrition:, Braegger, C., Decsi, T., Dias, J. A., Hartman, C., Kolaček, S., Koletzko, B., Koletzko, S., Mihatsch, W., Moreno, L., et al. (2010) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0b013e3181d336d2 · Cited by 317
Magnetic Living Hydrogels for Intestinal Localization, Retention, and Diagnosis
Liu, X., Yang, Y., Inda, M. E., Lin, S., Wu, J., Kim, Y., Chen, X., Ma, D., Lu, T. K., & Zhao, X. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010918 · Cited by 175
Sparks, D. A., Chase, D. M., Coughlin, L. M., & Perry, E. (2011) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607111413898 · Cited by 122
“Although novel, both of these techniques generally advocate a confirmatory postplacement X-ray despite presumed efficacy.(17,18) Repeat malpositions by blind technique present an even higher risk of morbid complications (Table 2).”
BackgroundWhite, H., Sosnowski, K., Tran, K., Reeves, A., & Jones, M. (2009) · Critical Care · doi:10.1186/cc8181 · Cited by 103
Metadata
- Authors
- Gabriel, S., & Ackermann, R.
- Venue
- Journal of Parenteral and Enteral Nutrition
- Publisher
- Wiley
- Published
- 2004-03
- Volume
- 28
- Issue
- 2
- Pages
- 119-122
- ISSN
- 0148-6071 (ISSN-L)
- 1941-2444
- OpenAlex
- W2020851685
- Cited by
- 58
- References
- 0
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Placement of nasoenteral feeding tubes using external magnetic guidance. https://app.cochat.ai/papers/10.1177/0148607104028002119
- The paper
- Gabriel, S., & Ackermann, R. (2004). Placement of nasoenteral feeding tubes using external magnetic guidance. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/0148607104028002119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.