Bedside Ultrasound Is a Practical and Reliable Measurement Tool for Assessing Quadriceps Muscle Layer Thickness
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Background : Critically ill patients commonly experience skeletal muscle wasting that may predict clinical outcome. Ultrasound is a noninvasive method that can measure muscle quadriceps muscle layer thickness (QMLT) and subsequently lean body mass (LBM) at the bedside. However, currently the reliability of these measurements are unknown. The objectives of this study were to evaluate the intra‐ and interreliability of measuring QMLT using bedside ultrasound. Methods : Ultrasound measurements of QMLT were conducted at 7 centers on healthy volunteers. Trainers were instructed to perform measurements twice on each patient, and then a second trainee repeated the measurement. Intrarater reliability measured how consistently the same person measured the subject according to intraclass correlation (ICC). Interrater reliability measured how consistently trainer and trainee agreed when measuring the same subject according to the ICC. Results : We collected 42 pairs of within operator measurements with an ICC of .98 and 78 pairs of trainer‐to‐trainee measurements with an ICC of .95. There were no statistically significant differences between the trainer and trainee results (trainer and trainee mean = −0.028 cm, 95% CI = −0.067 to −0.011, P = .1607). Conclusions : Excellent intra‐ and interrater reliability for ultrasound measurements of QMLT in healthy volunteers was observed when performed by a range of providers with no prior ultrasound experience, including dietitians, nurses, physicians, and research assistants. This technique shows promise as a method to evaluate LBM status in ICU or hospital settings and as a method to assess the effects of nutrition and exercise‐based interventions on muscle wasting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
One-Year Outcomes in Survivors of the Acute Respiratory Distress Syndrome
Herridge, M. S., Cheung, A. M., Tansey, C. M., Matte-Martyn, A., Diaz-Granados, N., Al-Saidi, F., Cooper, A. B., Guest, C. B., Mazer, C. D., Mehta, S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022450 · Cited by 2,334
Mourtzakis, M., Prado, C. M. M., Lieffers, J. R., Reiman, T., McCargar, L. J., & Baracos, V. E. (2008) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h08-075 · Cited by 2,224
Paresis Acquired in the Intensive Care Unit<SUBTITLE>A Prospective Multicenter Study</SUBTITLE>
De Jonghe, B. (2002) · JAMA · doi:10.1001/jama.288.22.2859 · Cited by 1,516
Acquired Weakness, Handgrip Strength, and Mortality in Critically Ill Patients
Ali, N. A., O'Brien, J. M., Hoffmann, S. P., Phillips, G., Garland, A., Finley, J. C. W., Almoosa, K., Hejal, R., Wolf, K. M., Lemeshow, S., et al. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200712-1829oc · Cited by 779
Gruther, W., Benesch, T., Zorn, C., Paternostro-Sluga, T., Quittan, M., Fialka-Moser, V, Spiss, C., Kainberger, F., & Crevenna, R. (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0139 · Cited by 377
Hermans, G., Clerckx, B., Vanhullebusch, T., Segers, J., Vanpee, G., Robbeets, C., Casaer, M. P., Wouters, P., Gosselink, R., & Van Den Berghe, G. (2012) · Muscle & Nerve · doi:10.1002/mus.22219 · Cited by 354
Sharshar, T., Bastuji-Garin, S., Stevens, R. D., Durand, M.-C., Malissin, I., Rodriguez, P., Cerf, C., Outin, H., & De Jonghe, B. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b027e9 · Cited by 268
Campbell, I., Watt, T., Withers, D., England, R., Sukumar, S., Keegan, M., Faragher, B., & Martin, D. (1995) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/62.3.533 · Cited by 162
Thomaes, T., Thomis, M., Onkelinx, S., Coudyzer, W., Cornelissen, V., & Vanhees, L. (2012) · BMC Medical Imaging · doi:10.1186/1471-2342-12-7 · Cited by 158
Structure to function: muscle failure in critically ill patients
Puthucheary, Z., Montgomery, H., Moxham, J., Harridge, S., & Hart, N. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2010.197632 · Cited by 102
Cited by
Lean Tissue Imaging: A New Era for Nutritional Assessment and Intervention
Prado, C. M. M., & Heymsfield, S. B. (2014) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607114550189 · Cited by 550
Parry, S. M., El-Ansary, D., Cartwright, M. S., Sarwal, A., Berney, S., Koopman, R., Annoni, R., Puthucheary, Z., Gordon, I. R., Morris, P. E., et al. (2015) · Journal of Critical Care · doi:10.1016/j.jcrc.2015.05.024 · Cited by 436
Metabolic and nutritional support of critically ill patients: consensus and controversies
Preiser, J.-C., van Zanten, A. R., Berger, M. M., Biolo, G., Casaer, M. P., Doig, G. S., Griffiths, R. D., Heyland, D. K., Hiesmayr, M., Iapichino, G., et al. (2015) · Critical Care · doi:10.1186/s13054-015-0737-8 · Cited by 416
“The use of techniques to assess lean tissue by ultrasound [67] or computed tomography scan”
MethodSelf-citationApplication of ultrasound for muscle assessment in sarcopenia: 2020 SARCUS update
Perkisas, S., Bastijns, S., Baudry, S., Bauer, J., Beaudart, C., Beckwée, D., Cruz-Jentoft, A., Gasowski, J., Hobbelen, H., Jager-Wittenaar, H., et al. (2021) · European Geriatric Medicine · doi:10.1007/s41999-020-00433-9 · Cited by 329
Sarcopenia: Current Concepts and Imaging Implications
Boutin, R. D., Yao, L., Canter, R. J., & Lenchik, L. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14635 · Cited by 323
Measurement of muscle mass in sarcopenia: from imaging to biochemical markers
Tosato, M., Marzetti, E., Cesari, M., Savera, G., Miller, R. R., Bernabei, R., Landi, F., & Calvani, R. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0717-0 · Cited by 320
Malnutrition Screening and Assessment
Serón-Arbeloa, C., Labarta-Monzón, L., Puzo-Foncillas, J., Mallor-Bonet, T., Lafita-López, A., Bueno-Vidales, N., & Montoro-Huguet, M. (2022) · doi:10.20944/preprints202205.0071.v1 · Cited by 312
Malnutrition Screening and Assessment
Serón-Arbeloa, C., Labarta-Monzón, L., Puzo-Foncillas, J., Mallor-Bonet, T., Lafita-López, A., Bueno-Vidales, N., & Montoro-Huguet, M. (2022) · Nutrients · doi:10.3390/nu14122392 · Cited by 310
Application of ultrasound for muscle assessment in sarcopenia: towards standardized measurements
Perkisas, S., Baudry, S., Bauer, J., Beckwée, D., De Cock, A.-M., Hobbelen, H., Jager-Wittenaar, H., Kasiukiewicz, A., Landi, F., Marco, E., et al. (2018) · European Geriatric Medicine · doi:10.1007/s41999-018-0104-9 · Cited by 255
Current technologies in body composition assessment: advantages and disadvantages
Ceniccola, G. D., Castro, M. G., Piovacari, S. M. F., Horie, L. M., Corrêa, F. G., Barrere, A. P. N., & Toledo, D. O. (2019) · Nutrition · doi:10.1016/j.nut.2018.11.028 · Cited by 252
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
“Sample protocol for taking ultrasound measurements of the quadriceps muscle.(205) • Please see the excellent training video on how to conduct ultrasound using maximal compression, created by Dr.”
BackgroundMethodSerum creatinine level, a surrogate of muscle mass, predicts mortality in critically ill patients
Thongprayoon, C., Cheungpasitporn, W., & Kashani, K. (2016) · Journal of Thoracic Disease · doi:10.21037/jtd.2016.03.62 · Cited by 232
“Table 2 shows the typical methods used for nutritional status and muscle mass assessment in ICUs (37-48).”
BackgroundMethodInfluentialParis, M. T., Mourtzakis, M., Day, A., Leung, R., Watharkar, S., Kozar, R., Earthman, C., Kuchnia, A., Dhaliwal, R., Moisey, L., et al. (2017) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607116637852 · Cited by 166
“The landmarks were on the anterior surface of the quadriceps from (1) the midpoint between the anterior superior iliac spine and the upper pole of the patella and (2) the border of the lower third and upper two-thirds between the anterior superior iliac spine and the upper pole of the patella, as previously described.…”
InfluentialSelf-citationCasey, P., Alasmar, M., McLaughlin, J., Ang, Y., McPhee, J., Heire, P., & Sultan, J. (2022) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.13041 · Cited by 164
Sheean, P., Gonzalez, M. C., Prado, C. M., McKeever, L., Hall, A. M., & Braunschweig, C. A. (2020) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.1669 · Cited by 164
Fetterplace, K., Deane, A. M., Tierney, A., Beach, L. J., Knight, L. D., Presneill, J., Rechnitzer, T., Forsyth, A., Gill, B. M. T., Mourtzakis, M., et al. (2018) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.1166 · Cited by 163
“Protein provided, g/d 94 (27) 58 (12) 37 (26–47) <.”
Winning the war against ICU-acquired weakness: new innovations in nutrition and exercise physiology
Wischmeyer, P. E., & San-Millan, I. (2015) · Critical Care · doi:10.1186/cc14724 · Cited by 153
“This technology is currently being validated in ICU patients, and we have shown it has excellent inter-rater and intra-rater reliability when performed by almost any caregiver including dieticians and nursing staff [23].”
MethodSelf-citationStoppe, C., Goetzenich, A., Whitman, G., Ohkuma, R., Brown, T., Hatzakorzian, R., Kristof, A., Meybohm, P., Mechanick, J., Evans, A., et al. (2017) · Critical Care · doi:10.1186/s13054-017-1690-5 · Cited by 138
Self-citationTeigen, L. M., Kuchnia, A. J., Mourtzakis, M., & Earthman, C. P. (2017) · Nutrition in Clinical Practice · doi:10.1177/0884533616676264 · Cited by 75
Smith, S., & Madden, A. M. (2016) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12372 · Cited by 67
Will We Ever Agree on Protein Requirements in the Intensive Care Unit?
Hoffer, L. J., Dickerson, R. N., Martindale, R. G., McClave, S. A., & Ochoa Gautier, J. B. (2017) · Nutrition in Clinical Practice · doi:10.1177/0884533617694613 · Cited by 17
Metadata
- Authors
- Tillquist, M., Kutsogiannis, D. J., Wischmeyer, P. E., Kummerlen, C., Leung, R., Stollery, D., Karvellas, C. J., Preiser, J., Bird, N., Kozar, R., & Heyland, D. K.
- Venue
- Journal of Parenteral and Enteral Nutrition
- Publisher
- Wiley
- Published
- 2013-08-26
- Volume
- 38
- Issue
- 7
- Pages
- 886-890
- ISSN
- 0148-6071 (ISSN-L)
- 1941-2444
- OpenAlex
- W2094825334
- Cited by
- 281
- References
- 13
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.