CoChat

A Validation and Comparison Study of Two Metabolic Monitors

Phang, P. Terry, Rich, Tom, Ronco, Juan · 1990 · Journal of Parenteral and Enteral Nutrition
Cited by 106

The DOI matches its Crossref record.

Abstract

Two portable metabolic cart systems of indirect calorimetry (Deltatrac Metabolic Monitor, 2900 MMC System) were validated. CO 2 and N 2 were delivered at precise rates into a constructed lung model to simulate CO 2 production (VCO 2) and O 2 consumption (VO 2). VCO 2 (200–400 ml/min) and VO 2 (250–750 ml/min) were measured at varying combinations of minute ventilation (VE) (6, 10, 20 liter/min) and FiO 2 (0.21, 0.30, 0.60, 0.80). VCO 2 was measured with overall errors of 1.5% and 2.4% for the Deltatrac and 2900 monitors, respectively. VO 2 was measured with overall errors of 1.9% and 3.2% by the Deltatrac and 2900 monitors, respectively. Both monitors performed equally well for measurement of VO 2 at FiO 2 up to 0.6, but the Deltatrac had less error for measurements of VO 2 at FiO 2 of 0.8. (Journal of Parenteral and Enteral Nutrition 14:259–261, 1990)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0148607190014003259

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 106

Metadata

Authors
Phang, P. T., Rich, T., & Ronco, J.
Venue
Journal of Parenteral and Enteral Nutrition
Publisher
Wiley
Published
1990-05
Volume
14
Issue
3
Pages
259-261
ISSN
  • 0148-6071 (ISSN-L)
  • 1941-2444
OpenAlex
W2033302228
Cited by
106
References
0
FWCI
5.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Validation and Comparison Study of Two Metabolic Monitors. https://app.cochat.ai/papers/10.1177/0148607190014003259
The paper
Phang, P. T., Rich, T., & Ronco, J. (1990). A Validation and Comparison Study of Two Metabolic Monitors. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/0148607190014003259

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.