Biocompatibility: Meeting a Key Functional Requirement of Next-Generation Medical Devices
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
The array of polymeric, biologic, metallic, and ceramic biomaterials will be reviewed with respect to their biocompatibility, which has traditionally been viewed as a requirement to develop a safe medical device. With the emergence of combination products, a paradigm shift is occurring that now requires biocompatibility to be designed into the device. In fact, next-generation medical devices will require enhanced biocompatibility by using, for example, pharmacological agents, bioactive coatings, nanotextures, or hybrid systems containing cells that control biologic interactions to have desirable biologic outcomes. The concept of biocompatibility is moving from a “do no harm” mission (i.e., nontoxic, nonantigenic, nonmutagenic, etc.) to one of doing “good,” that is, encouraging positive healing responses. These new devices will promote the formation of normal healthy tissue as well as the integration of the device into adjacent tissue. In some contexts, biocompatibility can become a disruptive technology that can change therapeutic paradigms (e.g., drug-coated stents). New database tools to access biocompatibility data of the materials of construction in existing medical devices will facilitate the use of existing and new biomaterials for new medical device designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Sousa, J. E., Costa, M. A., Abizaid, A., Abizaid, A. S., Feres, F., Pinto, I. M. F., Seixas, A. C., Staico, R., Mattos, L. A., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.2.192 · Cited by 793
Biocompatibility of clinical implant materials
Williams, D. F. (1981) · CRC Press eBooks · Cited by 773
Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy
Wever, D. J., Veldhuizen, A. G., Sanders, M. M., Schakenraad, J. M., & van Horn, J. R. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00041-0 · Cited by 373
Fürst, W., & Banerjee, A. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.11.054 · Cited by 295
Attachment and proliferation of osteoblasts and fibroblasts on biomaterials for orthopaedic use
Hunter, A., Archer, C. W., Walker, P. S., & Blunn, G. W. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93256-d · Cited by 274
Brash, J. L. (2000) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856200744237 · Cited by 201 · cited 1×
“…of this healing process can have profound implications on the success of a device and can depend on material properties such as texture, crystallinity, wettability, surface chemistry, cytotoxic leachables, and degradation products (Andrade et al., 1987; Brash, 2000; Helmus and Tweden, 1995).”
BackgroundRanade, S. V., Miller, K. M., Richard, R. E., Chan, A. K., Allen, M. J., & Helmus, M. N. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30188 · Cited by 185 · cited 5×
“Drug–polymer combinations have been used in drug-eluting stents, heparin-release coatings for catheters, and steroid-releasing electrodes for pacemakers (Helmus and Tweden, 1995; Ranade et al., 2004; Ranade et al., 2005; Stokes, 1987).”
BackgroundInfluentialSelf-citationChang, Y., Tsai, C.-C., Liang, H.-C., & Sung, H.-W. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00379-9 · Cited by 174
Surfaces and Blood Compatibility Current Hypotheses
Andrade, J. D., Nagaoka, S., Cooper, S. L., OKANO, T., & KIM, S. W. (1987) · ASAIO Journal · doi:10.1097/00002480-198704000-00005 · Cited by 172 · cited 2×
“The outcome of this healing process can have profound implications on the success of a device and can depend on material properties such as texture, crystallinity, wettability, surface chemistry, cytotoxic leachables, and degradation products (Andrade et al., 1987; Brash, 2000; Helmus and Tweden, 1995).”
BackgroundTissue reaction to the biodegradable polylactic acid suture
Cutright, D. E., & Hunsuck, E. E. (1971) · Oral Surgery Oral Medicine Oral Pathology · doi:10.1016/0030-4220(71)90044-2 · Cited by 144
Encyclopedia of Medical Devices and Instrumentation
Griffiths, H. J. (1989) · Radiology · doi:10.1148/radiology.170.3.1016 · Cited by 140
Styrenic block copolymers for biomaterial and drug delivery applications
Ranade, S. V., Richard, R. E., & Helmus, M. N. (2004) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.004 · Cited by 124 · cited 6×
“Drug–polymer combinations have been used in drug-eluting stents, heparin-release coatings for catheters, and steroid-releasing electrodes for pacemakers (Helmus and Tweden, 1995; Ranade et al., 2004; Ranade et al., 2005; Stokes, 1987).”
BackgroundInfluentialSelf-citationBlood Compatible Materials and Devices
Nunes, B. (1991) · Journal of Clinical Engineering · doi:10.1097/00004669-199103000-00014 · Cited by 103
Marois, Y. (1996) · Biomaterials · doi:10.1016/0142-9612(96)80749-6 · Cited by 97
In vitro study of the intrinsic toxicity of synthetic surfaces to cells
Ertel, S. I., Ratner, B. D., Kaul, A., Schway, M. B., & Horbett, T. A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280603 · Cited by 95
Factors and Interactions Affecting the Performance of Polyurethane Elastomers in Medical Devices
Coury, A. J., Slaikeu, P. C., Cahalan, P. T., Stokes, K. B., & Hobot, C. M. (1988) · Journal of Biomaterials Applications · doi:10.1177/088532828800300202 · Cited by 93 · cited 2×
“Cytotoxic leachables and degradation products, which may exhibit systemic effects if the dose is high, may result from the fabrication and sterilization methods used as well as ambient degradation by processes such as hydrolysis and oxidation over time (Coury et al., 1988; Stokes, 1987; Takahara et al., 1992).”
MethodClinical and angiographic outcome after coronary arterial stenting with the carbostent
Antoniucci, D., Bartorelli, A. L., Valenti, R., Montorsi, P., Santoro, G. M., Fabbiocchi, F., Bolognese, L., Loaldi, A., Trapani, M., Trabattoni, D., et al. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00874-7 · Cited by 87 · cited 1×
“(1975) Synthetic elastomer Silicone rubber Sewing ring component 3, 5, 6, 10, 11 Belanger et al. (2000), Harmand and Briquet (1999), Iomhair and pericardial heart valve Lavelle (1996), McCoy et al.”
MethodTakahara, A., Hergenrother, R. W., Coury, A. J., & Cooper, S. L. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260609 · Cited by 86
Feng, L., & Andrade, J. D. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280611 · Cited by 83
A novel polymer for potential use in a trileaflet heart valve
Gallocher, S. L., Aguirre, A. F., Kasyanov, V. A., Pinchuk, L., & Schoephoerster, R. T. (2006) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30546 · Cited by 78
Complement Activation in Extracorporeal Circuits
CHENOWETH, D. E. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb33051.x · Cited by 75 · cited 1×
“Some negatively charged surfaces initiate the degradation of complement components with the potential for fewer side effects for extracorporeal treatments such as dialysis (Chenoweth, 1987).”
BackgroundExpandable Bioresorbable Endovascular Stent. I. Fabrication and Properties
Su, S., Chao, R., Landau, C., Nelson, K. D., Timmons, R. B., Meidell, R. S., & Eberhart, R. C. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1575756 · Cited by 73
Wear characteristic and biocompatibility of some polymer composite acetabular cups
Chowdhury, S. K. R., Mishra, A. R., Pradhan, B., & Saha, D. (2003) · Wear · doi:10.1016/s0043-1648(03)00535-0 · Cited by 70
Engineering aspects of stents design and their translation into clinical practice.
Sangiorgi, G., Melzi, G., Agostoni, P., Cola, C., Clementi, F., Romitelli, P., Virmani, R., & Colombo, A. (2007) · PubMed · Cited by 65
Bélanger, M., Marois, Y., Roy, R., Mehri, Y., Wagner, É., Zhang, Z., King, M. W., Yang, M., Hahn, C., & Guidoin, R. (2000) · Artificial Organs · doi:10.1046/j.1525-1594.2000.06504.x · Cited by 64
Goreish, H. H., Lewis, A. L., Rose, S., & Lloyd, A. W. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10141 · Cited by 61 · cited 1×
“Phosphorylcholine-derived polymers have been used to produce thromboresistant and biocompatible surfaces (De et al., 2002; Galli et al., 2001; Rose et al., 2004; Malik et al., 2001; Goreish et al., 2004).”
BackgroundIn vitro hemocompatibility studies of drug-loaded poly-(l-lactic acid) fibers
Nguyen, K. T., Su, S., Sheng, A.-L., Wawro, D. D., Schwade, N. D., Brouse, C. F., Greilich, P. E., Tang, L., & Eberhart, R. C. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00451-4 · Cited by 61
Marois, Y., MARIE-FRANCOISE, SUGOT-LUIZARD, & Guidoin, R. (1999) · ASAIO Journal · doi:10.1097/00002480-199907000-00005 · Cited by 60
Biological responses to cationically charged phosphorylcholine-based materials in vitro
Rose, S. F., Lewis, A. L., Hanlon, G. W., & Lloyd, A. W. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.016 · Cited by 60 · cited 1×
“Phosphorylcholine-derived polymers have been used to produce thromboresistant and biocompatible surfaces (De et al., 2002; Galli et al., 2001; Rose et al., 2004; Malik et al., 2001; Goreish et al., 2004).”
BackgroundLevy, R. J., Vyavahare, N. R., Ogle, M., Ashworth, P. E., Bianco, R. W., & Schöen, F. J. (2003) · PubMed · Cited by 53
Paclitaxel‐Eluting Stents: Are They All Equal?
Silber, S. (2003) · Journal of Interventional Cardiology · doi:10.1046/j.1540-8183.2003.01065.x · Cited by 40
Spilizewski, K. L., Marchant, R. E., Anderson, J. M., & Hiltner, A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90021-4 · Cited by 38
The need for rules and regulations
Helmus, M. N. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.165 · Cited by 35
Self-citationWerthén, M., Sellborn, A., Källtorp, M., Elwing, H. B., & Thomsen, P. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00246-5 · Cited by 34
Cytocompatibility study of NHLBI primary reference materials using human endothelial cells
Bordenave, L., Bareille, R., Lefèbvre, F., Caix, J., & Baquey, C. (1992) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856292x00475 · Cited by 24 · cited 1×
“Synthetic plastic Ultra high molecular Annuloplasty rings 3, 4, 6, 10, 11 Chowdhury et al. (2004), Takami et al.”
BackgroundEberhart, R. C., Huo, H.-H., & Nelson, K. M. (1991) · MRS Bulletin · doi:10.1557/s0883769400056062 · Cited by 15
Urayama, H., Kasashima, F., Kawakami, T., Kawakami, K., & Watanabe, Y. (1996) · Artificial Organs · doi:10.1111/j.1525-1594.1996.tb04414.x · Cited by 13
Acute and chronic canine ex vivo blood interactions with NHLBI-DTB Primary Reference Materials
McCoy, T. J., Grasel, T. G., Okkema, A. Z., & Cooper, S. L. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90100-2 · Cited by 11
Cited by
Oxidized Alginate-Based Hydrogels for Tissue Engineering Applications: A Review
Reakasame, S., & Boccaccini, A. R. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.7b01331 · Cited by 408
Zhang, J., Rector, J., Lin, J. Q., Young, J. H., Sans, M., Katta, N., Giese, N., Yu, W., Nagi, C., Suliburk, J., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aan3968 · Cited by 406
Biological responses to physicochemical properties of biomaterial surface
Rahmati, M., Silva, E. A., Reseland, J. E., A. Heyward, C., & Haugen, H. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00103a · Cited by 391
Arifin, A., Sulong, A. B., Muhamad, N., Syarif, J., & Ramli, M. I. (2014) · Materials & Design · doi:10.1016/j.matdes.2013.09.045 · Cited by 349
Nanoporous inorganic membranes or coatings for sustained drug delivery in implantable devices
Gultepe, E., Nagesha, D., Sridhar, S., & Amiji, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.003 · Cited by 304
Metadata
- Authors
- Helmus, M. N., Gibbons, D. F., & Cebon, D.
- Venue
- Toxicologic Pathology
- Publisher
- SAGE Publications
- Published
- 2008-01
- Volume
- 36
- Issue
- 1
- Pages
- 70-80
- ISSN
- 0192-6233 (ISSN-L)
- 1533-1601
- OpenAlex
- W2142960025
- Cited by
- 170
- References
- 42
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.