CoChat

Generalization of endothelial modelling of TSPO PET imaging: Considerations on tracer affinities

Open access
Rizzo, Gaia, Veronese, Mattia, Tonietto, Matteo, Bodini, Benedetta, Stankoff, Bruno, Wimberley, Catriona, Lavisse, Sonia, Bottlaender, Michel, Bloomfield, Peter S, Howes, Oliver, Zanotti-Fregonara, Paolo, Turkheimer, Federico E, Bertoldo, Alessandra · 2019 · Journal of Cerebral Blood Flow & Metabolism
Cited by 49

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

The 18 kDa translocator protein (TSPO) is a marker of microglia activation and the main target of positron emission tomography (PET) ligands for neuroinflammation. Previous works showed that accounting for TSPO endothelial binding improves PET quantification for [11 C]PBR28, [18 F]DPA714 and [11 C]-R-PK11195. It is still unclear, however, whether the vascular signal is tracer-dependent. This work aims to explore the relationship between the TSPO vascular and tissue components for PET tracers with varying affinity, also assessing the impact of affinity towards the differentiability amongst kinetics and the ensuing ligand amenability to cluster analysis for the extraction of a reference region. First, we applied the compartmental model accounting for vascular binding to [11 C]-R-PK11195 data from six healthy subjects. Then, we compared the [11 C]-R-PK11195 vascular binding estimates with previously published values for [18 F]DPA714 and [11 C]PBR28. Finally, we determined the suitability for reference region extraction by calculating the angle between grey and white matter kinetics. Our results showed that endothelial binding is common to all TSPO tracers and proportional to their affinity. By consequence, grey and white matter kinetics were most similar for the radioligand with the highest affinity (i.e. [11 C]PBR28), hence poorly suited for the extraction of a reference region using supervised clustering.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0271678x17742004

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 49

Metadata

Authors
Rizzo, G., Veronese, M., Tonietto, M., Bodini, B., Stankoff, B., Wimberley, C., Lavisse, S., Bottlaender, M., Bloomfield, P. S., Howes, O., Zanotti-Fregonara, P., Turkheimer, F. E., & Bertoldo, A.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
2017-11-14
Volume
39
Issue
5
Pages
874-885
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2770089247
Cited by
49
References
9
FWCI
3.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Generalization of endothelial modelling of TSPO PET imaging: Considerations on tracer affinities. https://app.cochat.ai/papers/10.1177/0271678x17742004
The paper
Rizzo, G., Veronese, M., Tonietto, M., Bodini, B., Stankoff, B., Wimberley, C., Lavisse, S., Bottlaender, M., Bloomfield, P. S., Howes, O., Zanotti-Fregonara, P., Turkheimer, F. E., & Bertoldo, A. (2019). Generalization of endothelial modelling of TSPO PET imaging: Considerations on tracer affinities. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1177/0271678x17742004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.