The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.
A Series Elastic- and Bowden-Cable-Based Actuation System for Use as Torque Actuator in Exoskeleton-Type Robots
Abstract
Within the context of impedance controlled exoskeletons, common actuators have important drawbacks. Either the actuators are heavy, have a complex structure or are poor torque sources, due to gearing or heavy nonlinearity. Considering our application, an impedance controlled gait rehabilitation robot for treadmill-training, we designed an actuation system that might avoid these drawbacks. It combines a lightweight joint and a simple structure with adequate torque source quality. It consists of a servomotor, a flexible Bowden cable transmission, and a force feedback loop based on a series elastic element. A basic model was developed that is shown to describe the basic dynamics of the actuator well enough for design purpose. Further measurements show that performance is sufficient for use in a gait rehabilitation robot. The demanded force tracking bandwidths were met: 11 Hz bandwidth for the full force range (demanded 4 Hz) and 20 Hz bandwidth for smaller force range (demanded 12 Hz). The mechanical output impedance of the actuator could be reduced to hardly perceptible level. Maxima of about 0.7 Nm peaks for 4 Hz imposed motions appeared, corresponding to less than 2.5% of the maximal force output. These peaks were caused by the stick friction in the Bowden cables. Spring stiffness variation showed that both a too stiff and a too compliant spring can worsen performance. A stiff spring reduces the maximum allowable controller gain. The relatively low control gain then causes a larger effect of stick in the force output, resulting in a less smooth output in general. Low spring stiffness, on the other side, decreases the performance of the system, because saturation will occur sooner.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Literature has suggested that physical guiding lower limb movement may decrease motor learning, and the patient's effort and participation in the training, and thus may not achieve effective training [57].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [57]
Citations
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Understanding the pattern of functional recovery after stroke: Facts and theories
Kwakkel, G., Kollen, B., & Lindeman, E. (2004) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2004-00282 · Cited by 727
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B., Morse, C., & Collins, S. H. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307425 · Cited by 571
Virtual Model Control: An Intuitive Approach for Bipedal Locomotion
Pratt, J. E., Chew, C., Torres, A. L., Dilworth, P., & Pratt, G. A. (2001) · The International Journal of Robotics Research · doi:10.1177/02783640122067309 · Cited by 547
A New Actuation Approach for Human Friendly Robot Design
Zinn, M., Roth, B., Khatib, O., & Salisbury, J. K. (2004) · The International Journal of Robotics Research · doi:10.1177/0278364904042193 · Cited by 441
Series elastic actuator development for a biomimetic walking robot
Robinson, D. W., Pratt, J. E., Paluska, D., & Pratt, G. A. (1999) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.1999.803231 · Cited by 417
Robotics, Motor Learning, and Neurologic Recovery
Reinkensmeyer, D. J., Emken, J. L., & Cramer, S. C. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140223 · Cited by 415
Upper and lower extremity robotic devices for rehabilitation and for studying motor control
Hesse, S., Schmidt, H., Werner, C., & Bardeleben, A. (2003) · Current Opinion in Neurology · doi:10.1097/00019052-200312000-00010 · Cited by 369
Cited by
Sorted by citations
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,281
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“Literature has suggested that physical guiding lower limb movement may decrease motor learning, and the patient’s effort and participation in the training, and thus may not achieve effective training [57].”
BackgroundLower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2014) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 461
Compliant actuation of rehabilitation robots
Vallery, H., Veneman, J. F., van Asseldonk, E. H. F., Ekkelenkamp, R., BUSS, M. J., & van der Kooij, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927689 · Cited by 450
Human–Robot Interaction Control of Rehabilitation Robots With Series Elastic Actuators
Yu, H., Huang, S., Chen, G., Pan, Y., & Guo, Z. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2457314 · Cited by 356
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 320
Towards more effective robotic gait training for stroke rehabilitation: a review
Pennycott, A., Wyss, D., Vallery, H., Klamroth-Marganska, V., & Riener, R. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-65 · Cited by 265
A light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 257
NEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
Clutchable series-elastic actuator: Implications for prosthetic knee design
Rouse, E. J., Mooney, L. M., & Herr, H. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914545673 · Cited by 235
Reference Trajectory Generation for Rehabilitation Robots: Complementary Limb Motion Estimation
Vallery, H., van Asseldonk, E. H. F., BUSS, M. J., & van der Kooij, H. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008278 · Cited by 234
Go, J., Schiffres, S. N., Stevens, A. G., & Hart, A. J. (2017) · Additive manufacturing · doi:10.1016/j.addma.2017.03.007 · Cited by 238
Adaptive Impedance Control of a Robotic Orthosis for Gait Rehabilitation
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2012) · IEEE Transactions on Cybernetics · doi:10.1109/tsmcb.2012.2222374 · Cited by 224
Adaptive Human–Robot Interaction Control for Robots Driven by Series Elastic Actuators
Li, X., Pan, Y., Gong, C., & Yu, H. (2016) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2626479 · Cited by 203
Agarwal, P., Fox, J., Yun, Y., O’Malley, M. K., & Deshpande, A. D. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364915598388 · Cited by 189
Sensors and Actuation Technologies in Exoskeletons: A Review
Tiboni, M., Borboni, A., Vérité, F., Bregoli, C., & Amici, C. (2022) · Sensors · doi:10.3390/s22030884 · Cited by 188
Modeling, Identification, and Control of Tendon-Based Actuation Systems
Palli, G., Borghesan, G., & Melchiorri, C. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2171610 · Cited by 180
Passive and accurate torque control of series elastic actuators
Vallery, H., Ekkelenkamp, R., van der Kooij, H., & Buss, M. (2007) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2007.4399172 · Cited by 171
Modeling of Transmission Characteristics Across a Cable-Conduit System
Agrawal, V., Peine, W. J., & Yao, B. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2064014 · Cited by 167
Novel gait adaptation and neuromotor training results using an active leg exoskeleton
Banala, S. K., Agrawal, S. K., Kim, S. H., & Scholz, J. P. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2041245 · Cited by 165
Self-Alignment Mechanisms for Assistive Wearable Robots: A Kinetostatic Compatibility Method
Cempini, M., Rossi, S., Lenzi, T., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2226381 · Cited by 157
Cao, J., Xie, S. Q., Das, R., & Zhu, G. L. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.08.005 · Cited by 153
Chen, T., Casas, R., & Lum, P. S. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2930915 · Cited by 150
An oscillator-based smooth real-time estimate of gait phase for wearable robotics
Yan, T., Parri, A., Garate, V. R., Cempini, M., Ronsse, R., & Vitiello, N. (2016) · Autonomous Robots · doi:10.1007/s10514-016-9566-0 · Cited by 140
Biomechanical considerations in the design of lower limb exoskeletons
Cenciarini, M., & Dollar, A. M. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975366 · Cited by 139
Design and development of lower limb exoskeletons: A survey
Aliman, N., Ramli, R., & Haris, S. M. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2017.05.013 · Cited by 133
Tele-impedance based assistive control for a compliant knee exoskeleton
Karavas, N. C., Ajoudani, A., Tsagarakis, N. G., Saglia, J. A., Bicchi, A., & Caldwell, D. G. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.027 · Cited by 130
An Acceleration-Based Robust Motion Controller Design for a Novel Series Elastic Actuator
Sarıyıldız, E., Gong, C., & Yu, H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2512228 · Cited by 130
A Novel Compact Torsional Spring for Series Elastic Actuators for Assistive Wearable Robots
Carpino, G., Accoto, D., Sergi, F., Tagliamonte, N. L., & Guglielmelli, E. (2012) · Journal of Mechanical Design · doi:10.1115/1.4007695 · Cited by 129
Robot assisted gait training with active leg exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762885 · Cited by 127
System overview of bipedal robots Flame and TUlip: Tailor-made for Limit Cycle Walking
Hobbelen, D. G. E., de Boer, T., & Wisse, M. (2008) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2008.4650728 · Cited by 127
ZeroG: Overground gait and balance training system
Hidler, J. M., Brennan, D., Black, I., Nichols, D., Brady, K., & Nef, T. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.05.0098 · Cited by 127
Demonstration-based control of supernumerary robotic limbs
Llorens-Bonilla, B., Parietti, F., & Asada, H. H. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386055 · Cited by 126
Control design of a novel compliant actuator for rehabilitation robots
Yu, H., Sunan, H., Gong, C., & Thakor, N. V. (2013) · Mechatronics · doi:10.1016/j.mechatronics.2013.08.004 · Cited by 126
Mechanical design and evaluation of a compact portable knee–ankle–foot robot for gait rehabilitation
Chen, G., Qi, P., Guo, Z., & Yu, H. (2016) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2016.04.012 · Cited by 126
van Asseldonk, E. H. F., Veneman, J. F., Ekkelenkamp, R., Buurke, J. H., van der Helm, F. C. T., & van der Kooij, H. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.925074 · Cited by 124
A Highly Backdrivable, Lightweight Knee Actuator for Investigating Gait in Stroke
Sulzer, J. S., Roiz, R. A., Peshkin, M. A., & Patton, J. L. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019788 · Cited by 125
Rehabilitation and Health Care Robotics
der Loos, H. F. M. V., Reinkensmeyer, D. J., & Guglielmelli, E. (2016) · Springer handbooks · doi:10.1007/978-3-319-32552-1_64 · Cited by 127
Design of a Rotational Hydroelastic Actuator for a Powered Exoskeleton for Upper Limb Rehabilitation
Stienen, A. H. A., Hekman, E. E. G., ter Braak, H., Aalsma, A. M. M., van der Helm, F. C. T., & van der Kooij, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2018628 · Cited by 123
Sensing Pressure Distribution on a Lower-Limb Exoskeleton Physical Human-Machine Interface
Rossi, S., Vitiello, N., Lenzi, T., Ronsse, R., Koopman, B., Persichetti, A., Vecchi, F., Ijspeert, A. J., van der Kooij, H., & Carrozza, M. C. (2010) · Sensors · doi:10.3390/s110100207 · Cited by 120
Robot assisted treadmill training: Mechanisms and training strategies
Hussain, S., Xie, S. Q., & Liu, G. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.12.010 · Cited by 113
Transmission Model and Compensation Control of Double-Tendon-Sheath Actuation System
Wu, Q., Wang, X., Chen, L., & Du, F. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2360062 · Cited by 109
Experimental and numerical investigations of shape memory alloy helical springs
de Aguiar, R. A. A., Savi, M. A., & Pacheco, P. M. C. L. (2010) · Smart Materials and Structures · doi:10.1088/0964-1726/19/2/025008 · Cited by 106
Aguirre-Ollinger, G., & Yu, H. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2020.3034017 · Cited by 103
Kinematic and dynamic analysis of an anatomically based knee joint
Lee, K.-M., & Guo, J. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.02.001 · Cited by 101
Bracing the human body with supernumerary Robotic Limbs for physical assistance and load reduction
Parietti, F., Chan, K. C., & Asada, H. H. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6906601 · Cited by 99
Beyl, P., Damme, M. V., Ham, R. V., Vanderborght, B., & Lefeber, D. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2268942 · Cited by 98
Assist-as-Needed Control of an Intrinsically Compliant Robotic Gait Training Orthosis
Hussain, S., Jamwal, P. K., Ghayesh, M. H., & Xie, S. Q. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2580123 · Cited by 95
Sergi, F., Accoto, D., Carpino, G., Tagliamonte, N. L., & Guglielmelli, E. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290271 · Cited by 94
Rouse, E. J., Mooney, L. M., Martinez-Villalpando, E. C., & Herr, H. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650383 · Cited by 93
Wearable Ankle Robots in Post-stroke Rehabilitation of Gait: A Systematic Review
Shi, B., Chen, X., Yue, Z., Yin, S., Weng, Q., Zhang, X., Wang, J., & Wen, W. (2019) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2019.00063 · Cited by 94
Inverse Transmission Model and Compensation Control of a Single-Tendon–Sheath Actuator
Chen, L., Wang, X., & Xu, W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2258300 · Cited by 90
State-of-the-Art Robotic Devices for Wrist Rehabilitation: Design and Control Aspects
Hussain, S., Jamwal, P. K., van Vliet, P., & Ghayesh, M. H. (2020) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2020.2976905 · Cited by 90
A Flexible Sensor Technology for the Distributed Measurement of Interaction Pressure
Donati, M., Vitiello, N., Rossi, S., Lenzi, T., Crea, S., Persichetti, A., Giovacchini, F., Koopman, B., Podobnik, J., Munih, M., et al. (2013) · Sensors · doi:10.3390/s130101021 · Cited by 88
Design of Smart Modular Variable Stiffness Actuators for Robotic-Assistive Devices
Grosu, V., Rodriguez‐Guerrero, C., Grosu, S., Vanderborght, B., & Lefeber, D. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2704665 · Cited by 87
A novel hand exoskeleton with series elastic actuation for modulated torque transfer
Marconi, D., Baldoni, A., McKinney, Z., Cempini, M., Crea, S., & Vitiello, N. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.06.001 · Cited by 92
Generalization of Series Elastic Actuator Configurations and Dynamic Behavior Comparison
Lee, C. Y., Kwak, S., Kwak, J., & Oh, S. (2017) · Actuators · doi:10.3390/act6030026 · Cited by 86
Elongation Modeling and Compensation for the Flexible Tendon--Sheath System
Sun, Z., Wang, Z., & Phee, S. J. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2278613 · Cited by 86
Zhang, J., Dong, Y., Yang, C.-J., Geng, Y., Chen, Y., & Yang, Y. (2010) · Mechatronics · doi:10.1016/j.mechatronics.2010.02.003 · Cited by 86
Robust Nonlinear Control of an Intrinsically Compliant Robotic Gait Training Orthosis
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2012) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmca.2012.2207111 · Cited by 84
Dampace: Design of an Exoskeleton for Force-Coordination Training in Upper-Extremity Rehabilitation
Stienen, A. H. A., Hekman, E. E. G., Prange, G. B., Jannink, M. J. A., Aalsma, A. M. M., van der Helm, F. C. T., & van der Kooij, H. (2009) · Journal of Medical Devices · doi:10.1115/1.3191727 · Cited by 82
Toward Gait Symmetry Enhancement via a Cable-Driven Exoskeleton Powered by Series Elastic Actuators
Zhong, B., Guo, K., Yu, H., & Zhang, M. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3130639 · Cited by 81
Hussain, F., Goecke, R., & Mohammadian, M. (2021) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211032010 · Cited by 82
Hyun, D. J., Lim, H., Park, S.-I., & Nam, S. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2970448 · Cited by 77
Challenges and solutions for application and wider adoption of wearable robots
Babič, J., Laffranchi, M., Tessari, F., Verstraten, T., Novak, D., Šarabon, N., Uğurlu, B., Peternel, L., Torricelli, D., & Veneman, J. F. (2021) · Wearable Technologies · doi:10.1017/wtc.2021.13 · Cited by 79
Noda, T., Teramae, T., Uğurlu, B., & Morimoto, J. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6943062 · Cited by 74
Control of a robotic orthosis for gait rehabilitation
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2013) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2013.01.007 · Cited by 74
CURER: A Lightweight Cable-Driven Compliant Upper Limb Rehabilitation Exoskeleton Robot
Qian, W., Liao, J., Lu, L., Ai, L., Li, M., Xiao, X., & Guo, Z. (2022) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2022.3224423 · Cited by 73
Nested saturation based control of an actuated knee joint orthosis
Rifaï, H., Mohammed, S., Hassani, W., & Amirat, Y. (2013) · Mechatronics · doi:10.1016/j.mechatronics.2013.09.007 · Cited by 71
A second order sliding mode control and a neural network to drive a knee joint actuated orthosis
Mefoued, S. (2014) · Neurocomputing · doi:10.1016/j.neucom.2014.12.047 · Cited by 71
Generalized elasticities improve patient-cooperative control of rehabilitation robots
Vallery, H., Duschau-Wicke, A., & Riener, R. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209595 · Cited by 71
A novel revolute joint of variable stiffness with reconfigurability
Li, Z., & Bai, S. (2018) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2018.12.011 · Cited by 70
Passivity constraints for the impedance control of series elastic actuators
Tagliamonte, N. L., & Accoto, D. (2013) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/0959651813511615 · Cited by 69
Accoto, D., Carpino, G., Sergi, F., Tagliamonte, N. L., Zollo, L., & Guglielmelli, E. (2013) · International Journal of Advanced Robotic Systems · doi:10.5772/56927 · Cited by 69
Continuous sliding mode control of compliant robot arms: A singularly perturbed approach
Pan, Y., Li, X., Wang, H., & Yu, H. (2018) · Mechatronics · doi:10.1016/j.mechatronics.2018.04.005 · Cited by 69
Losey, D. P., Erwin, A., McDonald, C. G., Sergi, F., & O’Malley, M. K. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2557727 · Cited by 65
A Powered Hip Exoskeleton With High Torque Density for Walking, Running, and Stair Ascent
Ishmael, M. K., Archangeli, D., & Lenzi, T. (2022) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2022.3159506 · Cited by 67
Kinematics and design of a portable and wearable exoskeleton for hand rehabilitation
Cempini, M., Rossi, S., Lenzi, T., Cortese, M., Giovacchini, F., Vitiello, N., & Carrozza, M. C. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650414 · Cited by 64
A review of cable-driven rehabilitation devices
Xiong, H., & Diao, X. (2019) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2019.1629110 · Cited by 63
Mechanical design and friction modelling of a cable-driven upper-limb exoskeleton
Dežman, M., Asfour, T., Ude, A., & Gams, A. (2022) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2022.104746 · Cited by 62
Trevisani, A. (2009) · Mechatronics · doi:10.1016/j.mechatronics.2009.09.011 · Cited by 62
An intrinsically compliant robotic orthosis for treadmill training
Hussain, S., Xie, S. Q., Jamwal, P. K., & Parsons, J. G. M. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.02.003 · Cited by 62
Parietti, F., & Asada, H. H. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631123 · Cited by 59
NEUROExos: A variable impedance powered elbow exoskeleton
Lenzi, T., Vitiello, N., Rossi, S., Roccella, S., Vecchi, F., & Carrozza, M. C. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979866 · Cited by 59
Selective control of a subtask of walking in a robotic gait trainer(LOPES)
van Asseldonk, E. H. F., Ekkelenkamp, R., Veneman, J. F., van der Helm, F. C. T., & van der Kooij, H. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428522 · Cited by 58
Aguirre-Ollinger, G., Colgate, J. E., Peshkin, M. A., & Goswami, A. (2007) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2007.4399147 · Cited by 57
Design and Biomechanical Analysis of Supernumerary Robotic Limbs
Davenport, C., Parietti, F., & Asada, H. H. (2012) · doi:10.1115/dscc2012-movic2012-8790 · Cited by 53
Design and Control of a Polycentric Knee Exoskeleton Using an Electro-Hydraulic Actuator
Lee, T., Lee, D., Song, B., & Baek, Y. S. (2019) · Sensors · doi:10.3390/s20010211 · Cited by 52
Stepping Forward with Exoskeletons: Team IHMC?s Design and Approach in the 2016 Cybathlon
Griffin, R., Cobb, T., Craig, T., Daniel, M., van Dijk, N., Gines, J., Kramer, K., Shah, S., Siebinga, O., Smith, J., et al. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2754284 · Cited by 59
Exoskeleton transparency: feed-forward compensation vs. disturbance observer
Just, F., Özen, Ö., Bösch, P., Bobrovsky, H., Klamroth-Marganska, V., Riener, R., & Rauter, G. (2018) · at - Automatisierungstechnik · doi:10.1515/auto-2018-0069 · Cited by 51
Reliability analysis of a tendon-driven actuation for soft robots
Jeong, U., Kim, K., Kim, S.-H., Choi, H., Youn, B. D., & Cho, K. (2020) · The International Journal of Robotics Research · doi:10.1177/0278364920907151 · Cited by 51
Rehabilitation and Health Care Robotics
der Loos, H. F. M. V., & Reinkensmeyer, D. J. (2008) · Springer eBooks · doi:10.1007/978-3-540-30301-5_54 · Cited by 50
Mechanical design of a portable knee-ankle-foot robot
Yu, H., Cruz, M. S., Gong, C., Huang, S., Zhu, C., Chew, E., Ng, Y. S., & Thakor, N. V. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630870 · Cited by 48
Tosun, F. E., & Patoğlu, V. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2962332 · Cited by 48
Evaluation of a Fuzzy-Based Impedance Control Strategy on a Powered Lower Exoskeleton
Tran, H. T., Cheng, H., Huang, R., Lin, X., Duong, M.-K., & Chen, Q. (2015) · International Journal of Social Robotics · doi:10.1007/s12369-015-0324-9 · Cited by 47
Series Viscoelastic Actuators Can Match Human Force Perception
Parietti, F., Baud‐Bovy, G., Gatti, E., Riener, R., Guzzella, L., & Vallery, H. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2162076 · Cited by 47
A High-Performance Cable-Drive Module for the Development of Wearable Devices
Kuan, J., Pasch, K. A., & Herr, H. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2018.2822764 · Cited by 46
Liu, X., Zhou, Z., Mai, J., & Wang, Q. (2019) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2019.06.008 · Cited by 47
Cable Driven Rehabilitation Robots: Comparison of Applications and Control Strategies
Shoaib, M., Asadi, E., Cheong, J., & Bab‐Hadiashar, A. (2021) · IEEE Access · doi:10.1109/access.2021.3102107 · Cited by 46
Metadata
- Authors
- Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H.
- Affiliations
- University of Twente (NL)
- Biomechanical Engineering, BMTI University of Twente P.O. Box 217, 7500 AE Enschede The Netherlands
- ORCID
- Veneman, J. F.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2006-03
- Volume
- 25
- Issue
- 3
- Pages
- 261-281
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2147288676
- Cited by
- 428
- References
- 26
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 11 · 2023: 12 · 2022: 17 · 2021: 25 · 2020: 25 · 2019: 25 · 2018: 31 · 2017: 34 · 2016: 33 · 2015: 20 · 2014: 41 · 2013: 31 · 2012: 26
- FWCI
- 12.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The International Journal of Robotics Research (publishedVersion)
- University of Twente Research Information (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- University of Twente Research Information (submittedVersion)
- Funders
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Keywords
- series elastic actuator, torque actuators, impedance control, robotic exoskeleton, gait rehabilitation robot, treadmill training, force feedback, servo motor, spring stiffness, actuator dynamics modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review