The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.
A Series Elastic- and Bowden-Cable-Based Actuation System for Use as Torque Actuator in Exoskeleton-Type Robots
Abstract
Within the context of impedance controlled exoskeletons, common actuators have important drawbacks. Either the actuators are heavy, have a complex structure or are poor torque sources, due to gearing or heavy nonlinearity. Considering our application, an impedance controlled gait rehabilitation robot for treadmill-training, we designed an actuation system that might avoid these drawbacks. It combines a lightweight joint and a simple structure with adequate torque source quality. It consists of a servomotor, a flexible Bowden cable transmission, and a force feedback loop based on a series elastic element. A basic model was developed that is shown to describe the basic dynamics of the actuator well enough for design purpose. Further measurements show that performance is sufficient for use in a gait rehabilitation robot. The demanded force tracking bandwidths were met: 11 Hz bandwidth for the full force range (demanded 4 Hz) and 20 Hz bandwidth for smaller force range (demanded 12 Hz). The mechanical output impedance of the actuator could be reduced to hardly perceptible level. Maxima of about 0.7 Nm peaks for 4 Hz imposed motions appeared, corresponding to less than 2.5% of the maximal force output. These peaks were caused by the stick friction in the Bowden cables. Spring stiffness variation showed that both a too stiff and a too compliant spring can worsen performance. A stiff spring reduces the maximum allowable controller gain. The relatively low control gain then causes a larger effect of stick in the force output, resulting in a less smooth output in general. Low spring stiffness, on the other side, decreases the performance of the system, because saturation will occur sooner.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Literature has suggested that physical guiding lower limb movement may decrease motor learning, and the patient's effort and participation in the training, and thus may not achieve effective training [57].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [57]
Citations
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Understanding the pattern of functional recovery after stroke: Facts and theories
Kwakkel, G., Kollen, B., & Lindeman, E. (2004) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2004-00282 · Cited by 727
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B., Morse, C., & Collins, S. H. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307425 · Cited by 571
Virtual Model Control: An Intuitive Approach for Bipedal Locomotion
Pratt, J. E., Chew, C., Torres, A. L., Dilworth, P., & Pratt, G. A. (2001) · The International Journal of Robotics Research · doi:10.1177/02783640122067309 · Cited by 547
A New Actuation Approach for Human Friendly Robot Design
Zinn, M., Roth, B., Khatib, O., & Salisbury, J. K. (2004) · The International Journal of Robotics Research · doi:10.1177/0278364904042193 · Cited by 441
Series elastic actuator development for a biomimetic walking robot
Robinson, D. W., Pratt, J. E., Paluska, D., & Pratt, G. A. (1999) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.1999.803231 · Cited by 417
Robotics, Motor Learning, and Neurologic Recovery
Reinkensmeyer, D. J., Emken, J. L., & Cramer, S. C. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140223 · Cited by 415
Upper and lower extremity robotic devices for rehabilitation and for studying motor control
Hesse, S., Schmidt, H., Werner, C., & Bardeleben, A. (2003) · Current Opinion in Neurology · doi:10.1097/00019052-200312000-00010 · Cited by 369
Cited by
Sorted by citations
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,281
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“Literature has suggested that physical guiding lower limb movement may decrease motor learning, and the patient’s effort and participation in the training, and thus may not achieve effective training [57].”
BackgroundLower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2014) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 461
Compliant actuation of rehabilitation robots
Vallery, H., Veneman, J. F., van Asseldonk, E. H. F., Ekkelenkamp, R., BUSS, M. J., & van der Kooij, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927689 · Cited by 450
Metadata
- Authors
- Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H.
- Affiliations
- University of Twente (NL)
- Biomechanical Engineering, BMTI University of Twente P.O. Box 217, 7500 AE Enschede The Netherlands
- ORCID
- Veneman, J. F.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2006-03
- Volume
- 25
- Issue
- 3
- Pages
- 261-281
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2147288676
- Cited by
- 428
- References
- 26
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 11 · 2023: 12 · 2022: 17 · 2021: 25 · 2020: 25 · 2019: 25 · 2018: 31 · 2017: 34 · 2016: 33 · 2015: 20 · 2014: 41 · 2013: 31 · 2012: 26
- FWCI
- 12.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The International Journal of Robotics Research (publishedVersion)
- University of Twente Research Information (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- University of Twente Research Information (submittedVersion)
- Funders
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Keywords
- series elastic actuator, torque actuators, impedance control, robotic exoskeleton, gait rehabilitation robot, treadmill training, force feedback, servo motor, spring stiffness, actuator dynamics modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›