The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic control of continuum devices
Abstract
In this paper we apply Cosserat rod theory to catheters with permanent magnetic components that are subject to spatially varying magnetic fields. The resulting model formulation captures the magnetically coupled catheter behavior and provides numerical solutions for rod equilibrium configurations in real-time. The model is general, covering cases with different catheter geometries, multiple magnetic components, and various boundary constraints. The necessary Jacobians for quasi-static, closed-loop control using an electromagnetic coil system and a motorized advancer are derived and incorporated into a visual-feedback controller. We address the issue of solution bifurcations caused by the magnetic field by proposing an additional, stabilizing control method that makes use of system redundancies. We demonstrate the effectiveness of the model by performing 3D tip-position trajectories with root-mean-square distance errors of 2.7 mm in open-loop, 0.30 mm in closed-loop, and 0.42 mm in stabilizing closed-loop modes. The stabilizing controller achieved on average a factor of 1.6 increase in the restoring wrenches for the least stable direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847 · cited 1×
“AF can be treated with antiarrhythmic drugs or cardiac ablation, with a combined treatment plan showing the best results (Calkins et al., 2009).”
Background
Cited by
Ferromagnetic soft continuum robots
Kim, Y., Parada, G. A., Liu, S., & Zhao, X. (2019) · Science Robotics · doi:10.1126/scirobotics.aax7329 · Cited by 1,312
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Magnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
Zhang, M., Yang, L., Yang, H., Su, L., Xue, J., Wang, Q., Hao, B., Jiang, Y., Chan, K. F., Sung, J. J. Y., et al. (2025) · Science Advances · doi:10.1126/sciadv.adv1682 · Cited by 36
Metadata
- Authors
- Edelmann, J., Petruska, A. J., & Nelson, B. J.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2017-01
- Volume
- 36
- Issue
- 1
- Pages
- 68-85
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2575426328
- Cited by
- 194
- References
- 1
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic control of continuum devices. https://app.cochat.ai/papers/10.1177/0278364916683443
- The paper
- Edelmann, J., Petruska, A. J., & Nelson, B. J. (2017). Magnetic control of continuum devices. The International Journal of Robotics Research. https://doi.org/10.1177/0278364916683443
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.