The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Tele-impedance: Teleoperation with impedance regulation using a body–machine interface
Open accessAbstract
This work presents the concept of tele-impedance as a method for remotely controlling a robotic arm in interaction with uncertain environments. As an alternative to bilateral force-reflecting teleoperation control, in tele-impedance a compound reference command is sent to the slave robot including both the desired motion trajectory and impedance profile, which are then realized by the remote controller without explicit feedback to the operator. We derive the reference command from a novel body–machine interface (BMI) applied to the master operator’s arm, using only non-intrusive position and electromyography (EMG) measurements, and excluding any feedback from the remote site except for looking at the task. The proposed BMI exploits a novel algorithm to decouple the estimates of force and stiffness of the human arm while performing the task. The endpoint (wrist) position of the human arm is monitored by an optical tracking system and used for the closed-loop position control of the robot’s end-effector. The concept is demonstrated in two experiments, namely a peg-in-the-hole and a ball-catching task, which illustrate complementary aspects of the method. The performance of tele-impedance control is assessed by comparing the results obtained with the slave arm under either constantly low or high stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Internal models for motor control and trajectory planning.
Kawato, M. (1999) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(99)00028-8 · Cited by 2,685
Neural, mechanical, and geometric factors subserving arm posture in humans
Mussa-Ivaldi, F., Hogan, N., & Bizzi, E. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-10-02732.1985 · Cited by 1,158
The central nervous system stabilizes unstable dynamics by learning optimal impedance
Burdet, E., Osu, R., Franklin, D. W., Milner, T. E., & Kawato, M. (2001) · Nature · doi:10.1038/35106566 · Cited by 1,097
Albu-Schäffer, A., Ott, C., & Hirzinger, G. (2007) · The International Journal of Robotics Research · doi:10.1177/0278364907073776 · Cited by 815
Space teleoperation through time delay: review and prognosis
Sheridan, T. B. (1993) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.258052 · Cited by 765
Noninvasive Brain-Actuated Control of a Mobile Robot by Human EEG
del R. Millan, J., Renkens, F., Mourino, J., & Gerstner, W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827086 · Cited by 740
Role of Cocontraction in Arm Movement Accuracy
Gribble, P. L., Mullin, L. I., Cothros, N., & Mattar, A. (2003) · Journal of Neurophysiology · doi:10.1152/jn.01020.2002 · Cited by 660
Bicchi, A., & Tonietti, G. (2004) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2004.1310939 · Cited by 654
Self-citationThe DLR lightweight robot: design and control concepts for robots in human environments
Albu‐Schäffer, A., Haddadin, S., Ott, C., Stemmer, A., Wimböck, T., & Hirzinger, G. (2007) · Industrial Robot: An International Journal · doi:10.1108/01439910710774386 · Cited by 623
Telemanipulation with Time Delays
Niemeyer, G., & Slotine, J.-J. E. (2004) · The International Journal of Robotics Research · doi:10.1177/0278364904045563 · Cited by 539
Tonietti, G., Schiavi, R., & Bicchi, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570172 · Cited by 539
Self-citationTransactions of the American Nuclear Society
Ortiz-Rodriguez, J. M., Martínez-Blanco, M. D. R., Gallego, E., & Vega-Carrillo, H. R. (2009) · conference · Cited by 526
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
Human hand impedance characteristics during maintained posture
Tsuji, T., Morasso, P. G., Goto, K., & Ito, K. (1995) · Biological Cybernetics · doi:10.1007/bf00199890 · Cited by 469
Franklin, D. W., Osu, R., Burdet, E., Kawato, M., & Milner, T. E. (2003) · Journal of Neurophysiology · doi:10.1152/jn.01112.2002 · Cited by 442
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2009) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429
2010 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2010)
Nakao, M. (2011) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.29.443a2 · Cited by 409
Osu, R., Franklin, D. W., Kato, H., Gomi, H., Domen, K., Yoshioka, T., & Kawato, M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.2.991 · Cited by 380
Action and perception at the level of synergies
Turvey, M. T. (2007) · Human Movement Science · doi:10.1016/j.humov.2007.04.002 · Cited by 380
Bilateral controller for teleoperators with time delay via μ-synthesis
Leung, G. M. H., Francis, B. A., & Apkarian, J. (1995) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.345941 · Cited by 366
Gomi, H., & Osu, R. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08965.1998 · Cited by 352
Modulation of reflex EMG and stiffness in response to stretch of human finger muscle.
Akazawa, K., Milner, T. E., & Stein, R. B. (1983) · Journal of Neurophysiology · doi:10.1152/jn.1983.49.1.16 · Cited by 324
Wrist muscle activation patterns and stiffness associated with stable and unstable mechanical loads
De Serres, S. J., & Milner, T. E. (1991) · Experimental Brain Research · doi:10.1007/bf00228972 · Cited by 315
SELF-DIFFERENTIATION OF THE BASIC PATTERNS OF COORDINATION
WEISS, P. (1968) · Dynamics of Development: Experiments and Inferences · doi:10.1016/b978-1-4832-2919-5.50027-1 · Cited by 305
Encyclopedia of the Sciences of Learning
(2012) · Choice Reviews Online · doi:10.5860/choice.50-1234 · Cited by 237
Multijoint Muscle Regulation Mechanisms Examined by Measured Human Arm Stiffness and EMG Signals
Osu, R., & Gomi, H. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.4.1458 · Cited by 225
Dynamic and loaded impedance components in the maintenance of human arm posture
Dolan, J. M., Friedman, M. B., & Nagurka, M. L. (1993) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.256543 · Cited by 225
An EMG-Based Robot Control Scheme Robust to Time-Varying EMG Signal Features
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2040832 · Cited by 224
Time-varying mechanical behavior of multijointed arm in man
Lacquaniti, F., Carrozzo, M., & Borghese, N. A. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.5.1443 · Cited by 220
Brain–machine interfaces: computational demands and clinical needs meet basic neuroscience
Mussa-Ivaldi, F. (2003) · Trends in Neurosciences · doi:10.1016/s0166-2236(03)00121-8 · Cited by 175
A model of force and impedance in human arm movements
Tee, K. P., Burdet, E., Chew, C. M., & Milner, T. E. (2004) · Biological Cybernetics · doi:10.1007/s00422-004-0484-4 · Cited by 164
Compensation for loads during arm movements using equilibrium-point control
Gribble, P. L., & Ostry, D. J. (2000) · Experimental Brain Research · doi:10.1007/s002210000547 · Cited by 147
Shin, D., Kim, J., & Koike, Y. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00584.2007 · Cited by 134
Can co-activation reduce kinematic variability? A simulation study
Selen, L. P. J., Beek, P. J., & van Dieën, J. H. (2005) · Biological Cybernetics · doi:10.1007/s00422-005-0015-y · Cited by 123
Voluntary Control of Static Endpoint Stiffness During Force Regulation Tasks
Perreault, E. J., Kirsch, R. F., & Crago, P. E. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.87.6.2808 · Cited by 123
Inability to activate muscles maximally during cocontraction and the effect on joint stiffness
Milner, T. E., Cloutier, C., Leger, A. B., & Franklin, D. W. (1995) · Experimental Brain Research · doi:10.1007/bf00230049 · Cited by 114
EMG-based teleoperation and manipulation with the DLR LWR-III
Vogel, J., Castellini, C., & van der Smagt, P. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094739 · Cited by 112
Frequency spectrum analysis of wrist motion for activities of daily living
Mann, K. A., Wernere, F. W., & Palmer, A. K. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070219 · Cited by 107
Use of Self-Selected Postures to Regulate Multi-Joint Stiffness During Unconstrained Tasks
Trumbower, R. D., Krutky, M. A., Yang, B.-S., & Perreault, E. J. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005411 · Cited by 96
Contribution of geometry and joint stiffness to mechanical stability of the human arm
Milner, T. E. (2002) · Experimental Brain Research · doi:10.1007/s00221-002-1049-1 · Cited by 89
Analysis of mechanical impedance in human arm movements using a virtual tennis system
Tsuji, T., Takeda, Y., & Tanaka, Y. (2004) · Biological Cybernetics · doi:10.1007/s00422-004-0515-1 · Cited by 53
A compliant device for inserting a peg in a hole
McCallion, H., Johnson, G. R., & Pham, D. T. (1979) · Industrial Robot the international journal of robotics research and application · doi:10.1108/eb004754 · Cited by 41
Billard, A., & Grollman, D. H. (2012) · Springer eBooks · doi:10.1007/978-1-4419-1428-6_758 · Cited by 20
Cited by
Variable Impedance Control of Redundant Manipulators for Intuitive Human–Robot Physical Interaction
Ficuciello, F., Villani, L., & Siciliano, B. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2430053 · Cited by 449
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Adaptive Impedance Control for an Upper Limb Robotic Exoskeleton Using Biological Signals
Li, Z., Huang, Z., He, W., & Su, C.-Y. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2538741 · Cited by 323
Santello, M., Bianchi, M., Gabiccini, M., Ricciardi, E., Salvietti, G., Prattichizzo, D., Ernst, M., Moscatelli, A., Jörntell, H., Kappers, A. M. L., et al. (2016) · Physics of Life Reviews · doi:10.1016/j.plrev.2016.02.001 · Cited by 307
Self-citationStability Considerations for Variable Impedance Control
Kronander, K., & Billard, A. (2016) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2593492 · Cited by 284
Metadata
- Authors
- Ajoudani, A., Tsagarakis, N., & Bicchi, A.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2012-10-31
- Volume
- 31
- Issue
- 13
- Pages
- 1642-1656
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W1969976050
- Cited by
- 276
- References
- 43
- FWCI
- 17.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.