Abstract
In this paper we apply Cosserat rod theory to catheters with permanent magnetic components that are subject to spatially varying magnetic fields. The resulting model formulation captures the magnetically coupled catheter behavior and provides numerical solutions for rod equilibrium configurations in real-time. The model is general, covering cases with different catheter geometries, multiple magnetic components, and various boundary constraints. The necessary Jacobians for quasi-static, closed-loop control using an electromagnetic coil system and a motorized advancer are derived and incorporated into a visual-feedback controller. We address the issue of solution bifurcations caused by the magnetic field by proposing an additional, stabilizing control method that makes use of system redundancies. We demonstrate the effectiveness of the model by performing 3D tip-position trajectories with root-mean-square distance errors of 2.7 mm in open-loop, 0.30 mm in closed-loop, and 0.42 mm in stabilizing closed-loop modes. The stabilizing controller achieved on average a factor of 1.6 increase in the restoring wrenches for the least stable direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, R. A., & Johnson, C. R. (1985) · Cited by 22,203
Horn, R. A., & Johnson, C. R. (1985) · Cambridge University Press eBooks · doi:10.1017/cbo9780511810817 · Cited by 10,280 · cited 1×
“Thus, inversion must be performed with a least-squares method such as the Moore–Penrose pseudoinverse (Horn and Johnson, 1985).”
MethodA Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694 · cited 2×
“The rotation matrix R (Q) can be calculated using Rodrigues’s rotation formula (Murray et al., 1994)”
MethodImpact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575
Robotics: modelling, planning and control
(2009) · Choice Reviews Online · doi:10.5860/choice.46-6226 · Cited by 2,479 · cited 2×
“…in the distal position to the required changes in the control parameters[ İc L̇c ] = W−1J c,p ( Jc,pW −1 J c,p )−1 ṗdes, (65) thereby minimizing the cost functional 1 2 [ İc L̇c ] W [ İc L̇c ] (66) and allowing appropriate scaling between currents and length inputs (Siciliano et al., 2010).”
BackgroundFeinberg, W. M. (1995) · Archives of Internal Medicine · doi:10.1001/archinte.155.5.469 · Cited by 2,274
Nonlinear Problems of Elasticity
(2005) · Applied Mathematical Sciences · doi:10.1007/0-387-27649-1 · Cited by 1,670
Robotic Surgery: A Current Perspective
Lanfranco, A. R., Castellanos, A. E., Desai, J. P., & Meyers, W. C. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000103020.19595.7d · Cited by 1,299 · cited 1×
“Robotic-assisted interventions facilitate minimally invasive procedures by reducing invasiveness and enhancing accuracy and dexterity (Lanfranco et al., 2004; Mack, 2001).”
Method(1994) · Choice Reviews Online · doi:10.5860/choice.31-4381 · Cited by 1,215
OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
Self-citation
Cited by
Ferromagnetic soft continuum robots
Kim, Y., Parada, G. A., Liu, S., & Zhao, X. (2019) · Science Robotics · doi:10.1126/scirobotics.aax7329 · Cited by 1,312
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Magnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
Magnetic Actuation Systems for Miniature Robots: A Review
Yang, Z., & Zhang, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000082 · Cited by 388
Abbott, J. J., Diller, E., & Petruska, A. J. (2020) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-081219-082713 · Cited by 355
Self-citationMagnetic cilia carpets with programmable metachronal waves
Gu, H., Boehler, Q., Cui, H., Secchi, E., Savorana, G., De Marco, C., Gervasoni, S., Peyron, Q., Huang, T.-Y., Pane, S., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16458-4 · Cited by 329
Self-citationContinuum Robots for Medical Interventions
Dupont, P. E., Simaan, N., Choset, H., & Rucker, C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3141338 · Cited by 307
Jeon, S., Hoshiar, A. K., Kim, K., Lee, S., Kim, E., Lee, S., Kim, J.-Y., Nelson, B. J., Cha, H.-J., Yi, B.-J., et al. (2019) · Soft Robotics · doi:10.1089/soro.2018.0019 · Cited by 301
Self-citationChallenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Magnetically Actuated Continuum Medical Robots: A Review
Yang, Z., Yang, H., Cao, Y., Cui, Y., & Zhang, L. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200416 · Cited by 165
Zhang, M., Yang, L., Yang, H., Su, L., Xue, J., Wang, Q., Hao, B., Jiang, Y., Chan, K. F., Sung, J. J. Y., et al. (2025) · Science Advances · doi:10.1126/sciadv.adv1682 · Cited by 36
“The magnetic force and torque can be directly applied to the distal end, allowing it to maintain high maneuverability at small scales ( 27 , 28 ).”
Metadata
- Authors
- Edelmann, J., Petruska, A. J., & Nelson, B. J.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2017-01
- Volume
- 36
- Issue
- 1
- Pages
- 68-85
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2575426328
- Cited by
- 194
- References
- 35
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.