Whole-Slide Imaging and Automated Image Analysis: Considerations and Opportunities in the Practice of Pathology
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Digital pathology, the practice of pathology using digitized images of pathologic specimens, has been transformed in recent years by the development of whole-slide imaging systems, which allow for the evaluation and interpretation of digital images of entire histologic sections. Applications of whole-slide imaging include rapid transmission of pathologic data for consultations and collaborations, standardization and distribution of pathologic materials for education, tissue specimen archiving, and image analysis of histologic specimens. Histologic image analysis allows for the acquisition of objective measurements of histomorphologic, histochemical, and immunohistochemical properties of tissue sections, increasing both the quantity and quality of data obtained from histologic assessments. Currently, numerous histologic image analysis software solutions are commercially available. Choosing the appropriate solution is dependent on considerations of the investigative question, computer programming and image analysis expertise, and cost. However, all studies using histologic image analysis require careful consideration of preanalytical variables, such as tissue collection, fixation, and processing, and experimental design, including sample selection, controls, reference standards, and the variables being measured. The fields of digital pathology and histologic image analysis are continuing to evolve, and their potential impact on pathology is still growing. These methodologies will increasingly transform the practice of pathology, allowing it to mature toward a quantitative science. However, this maturation requires pathologists to be at the forefront of the process, ensuring their appropriate application and the validity of their results. Therefore, histologic image analysis and the field of pathology should co-evolve, creating a symbiotic relationship that results in high-quality reproducible, objective data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hsia, C. C. W., Hyde, D. M., Ochs, M., & Weibel, E. R. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200809-1522st · Cited by 902
Design-based stereology in neuroscience
Schmitz, C., & Hof, P. R. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2004.08.050 · Cited by 681 · cited 1×
“3,7,15,34 As part of new drug applications, it may be necessary to demonstrate that morphology-based analytical data obtained in preclinical studies are reproducible and representative of the organ as a whole, aspects that may be best demonstrated using stereolo-gic approaches.”
BackgroundOverview of telepathology, virtual microscopy, and whole slide imaging: Prospects for the future
Weinstein, R. S., Graham, A. R., Richter, L. C., Barker, G. P., Krupinski, E. A., Lopez, A. M., Erps, K. A., Bhattacharyya, A. K., Yagi, Y., & Gilbertson, J. R. (2009) · Human Pathology · doi:10.1016/j.humpath.2009.04.006 · Cited by 380 · cited 5×
“41 More recently, digital pathology has evolved to include whole-slide imaging, in which digital slide scanners are used to create digital images of entire histologic sections.”
BackgroundMethodInfluentialDigital pathology: current status and future perspectives
Al‐Janabi, S., Huisman, A., & Van Diest, P. J. (2012) · Histopathology · doi:10.1111/j.1365-2559.2011.03814.x · Cited by 363
Digital images and the future of digital pathology
Pantanowitz, L. (2010) · Journal of Pathology Informatics · doi:10.4103/2153-3539.68332 · Cited by 241 · cited 3×
“The transition from static to whole-slide imaging in digital pathology allows the consulting pathologist to evaluate the entire tissue section at multiple magnifications and eliminates the reliance on the submitter to select the correct regions of interest for evaluation.(26) However, in some environments, such as in…”
BackgroundMethodWhole-slide Imaging: Routine Pathologic Diagnosis
Cornish, T. C., Swapp, R. E., & Kaplan, K. J. (2012) · Advances in Anatomic Pathology · doi:10.1097/pap.0b013e318253459e · Cited by 161 · cited 10×
“Currently, upfront costs for many digital slide scanners are upwards of $100,000 and annual investments in service and maintenance contracts and technician support time are required.(8) Significant additional costs may be separately incurred for image analysis software licenses and, depending on needs and throughput,…”
BackgroundMethodInfluentialVirtual microscopy and digital pathology in training and education
Hamilton, P. W., Wang, Y., & McCullough, S. J. (2012) · APMIS · doi:10.1111/j.1600-0463.2011.02869.x · Cited by 158 · cited 7×
“be used to evaluate how trainees are making their interpretations and how that affects their final diagnosis.(13) An additional advantage of digital teaching slide sets is that they allow for easier distribution and sharing of histopathologic specimens.”
BackgroundMethodInfluentialEvaluating tumor heterogeneity in immunohistochemistry-stained breast cancer tissue
Potts, S. J., Krueger, J. S., Landis, N. D., Eberhard, D. A., Young, G. D., Schmechel, S. C., & Lange, H. (2012) · Laboratory Investigation · doi:10.1038/labinvest.2012.91 · Cited by 135 · cited 1×
“The field of pattern analysis is still developing, but applications such as assessment of tumor heterogeneity are beginning to emerge.(31)”
BackgroundAutomated image analysis in histopathology: a valuable tool in medical diagnostics
Mulrane, L., Rexhepaj, E., Penney, S., Callanan, J. J., & Gallagher, W. M. (2008) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.8.6.707 · Cited by 121 · cited 3×
“reviewed elsewhere, and comparing and contrasting image analysis packages is beyond the scope of this review.(25,33) However, it must be stated that each image analysis software package has its unique advantages and disadvantages.”
BackgroundMethodDigital pathology: exploring its applications in diagnostic surgical pathology practice
Jara‐Lazaro, A. R., Thamboo, T. P., Teh, M., & Tan, P. H. (2010) · Pathology · doi:10.3109/00313025.2010.508787 · Cited by 119
Cited by
A Practical Guide to Whole Slide Imaging: A White Paper From the Digital Pathology Association
Zarella, M. D., Bowman;, D., Aeffner, F., Farahani, N., Xthona;, A., Absar, S. F., Parwani, A., Bui, M., & Hartman, D. J. (2019) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2018-0343-ra · Cited by 404
Aeffner, F., Zarella, M. D., Buchbinder, N., Bui, M. M., Goodman, M. R., Hartman, D. J., Lujan, G. M., Molani, M. A., Parwani, A. V., Lillard, K., et al. (2019) · Journal of Pathology Informatics · doi:10.4103/jpi.jpi_82_18 · Cited by 403
Pathology image analysis using segmentation deep learning algorithms
Wang, S., Yang, D. M., Rong, R., Zhan, X., & Xiao, G. (2019) · The American Journal of Pathology · doi:10.1016/j.ajpath.2019.05.007 · Cited by 382
“The emergence of digital pathology 1,2 provides new opportunities to develop algorithms and software tools that can assist pathologists in clinical diagnosis and researchers in studying disease mechanisms.”
BackgroundDeep Convolutional Neural Networks Enable Discrimination of Heterogeneous Digital Pathology Images
Khosravi, P., Kazemi, E., Imielinski, M., Elemento, O., & Hajirasouliha, I. (2018) · EBioMedicine · doi:10.1016/j.ebiom.2017.12.026 · Cited by 334
“Although medical images are mostly interpreted by clinicians, the accuracy of their interpretation is reduced due to subjectivity, large variations across interpreters, and exhaustion (Greenspan et al., 2016; Webster and Dunstan, 2014).”
BackgroundArtificial Intelligence in Lung Cancer Pathology Image Analysis
Wang, S., Yang, D. M., Rong, R., Zhan, X., Fujimoto, J., Liu, H., Minna, J., Wistuba, I. I., Xie, Y., & Xiao, G. (2019) · Cancers · doi:10.3390/cancers11111673 · Cited by 291
Li, X., Li, C., Rahaman, M. M., Sun, H., Li, X., Wu, J., Yao, Y., & Grzegorzek, M. (2022) · Artificial Intelligence Review · doi:10.1007/s10462-021-10121-0 · Cited by 278
Cheng, N., Ren, Y., Zhou, J., Zhang, Y., Wang, D., Zhang, X., Chen, B., Liu, F., Lv, J., Cao, Q., et al. (2022) · Gastroenterology · doi:10.1053/j.gastro.2022.02.025 · Cited by 121
The Orthanc Ecosystem for Medical Imaging
Jodogne, S. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0082-y · Cited by 93
“Telepathology is potentially useful for intraoperative consultation [18], secondary consultation from experts [19], education, and research [20], and pathology archiving [21].”
Background
Metadata
- Authors
- Webster, J. D., & Dunstan, R. W.
- Venue
- Veterinary Pathology
- Publisher
- SAGE Publications
- Published
- 2013-10-03
- Volume
- 51
- Issue
- 1
- Pages
- 211-223
- ISSN
- 0300-9858 (ISSN-L)
- 1544-2217
- OpenAlex
- W2151753845
- Cited by
- 159
- References
- 32
- FWCI
- 10.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.