Double-Bundle Anterior Cruciate Ligament Reconstruction Using Hamstring Autografts and Bioabsorbable Interference Screw Fixation: Prospective, Randomized, Clinical Study with 2-Year Results
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background: Conventional anterior cruciate ligament reconstruction techniques have focused on restoration of the anterome-dial bundle only, which, however, may be insufficient in restoring the rotational stability of the knee. Hypothesis: Rotational stability of the knee is better when using a double-bundle technique instead of a single-bundle technique for anterior cruciate ligament reconstruction. Study Design: Randomized controlled clinical trial; Level of evidence, 1. Methods: Seventy-seven patients were randomized into 3 different groups for anterior cruciate ligament reconstruction with hamstring tendons: double-bundle with bioabsorbable screw fixation (n = 25), single-bundle with bioabsorbable screw fixation (n = 27), and single-bundle with metallic screw fixation (n = 25). The evaluation methods were clinical examination, KT-1000 arthrometric measurement, and the International Knee Documentation Committee and Lysholm knee scores. Results: There were no differences between the study groups preoperatively. Seventy-three patients (95%) were available at a minimum 2-year follow-up (range, 24–35 mo). The rotational stability of the knee, as evaluated by the pivot-shift test, was the best in the patients in the double-bundle group. In addition, the patients in the single-bundle groups had more graft failures than those in the double-bundle group. Concerning the anterior stability of the knee as measured with the KT-1000 arthrometer, the group differences were not statistically significant. No significant differences were found between the groups in knee scores. Conclusion: Rotational stability of the knee is better when using the double-bundle technique instead of the single-bundle technique in anterior cruciate ligament reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale
Lysholm, J., & Gillquist, J. (1982) · The American Journal of Sports Medicine · doi:10.1177/036354658201000306 · Cited by 2,775
The Cruciate Ligaments of the Knee Joint: Anatomical. Functional and Experimental Analysis
Girgis, F. G., Marshall, J. L., & MONA JEM, A. R. S. A. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197501000-00033 · Cited by 1,485
Biomechanical Analysis of an Anatomic Anterior Cruciate Ligament Reconstruction
Yagi, M., Wong, E. K., Kanamori, A., Debski, R. E., Fu, F. H., & Woo, S. L.-Y. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300050501 · Cited by 988 · cited 1×
“Also, it has been shown in a cadaver model that anatomic double-bundle reconstructions are able to more closely restore the normal kinematics of the knee when compared with the single-bundle technique.(31) Thus, all these findings suggest that there is a need for a more anatomical ACL reconstruction using a design tha…”
BackgroundInstrumented measurement of anterior laxity of the knee.
Daniel, D. M., Malcom, L. L., Losse, G., Stone, M. L., Sachs, R., & Burks, R. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00006 · Cited by 749 · cited 1×
“The routine evaluation methods were clinical examination and stability measurement with the KT-1000 arthrometer with a force of 134 N (MEDmetric Corporation, San Diego, Calif) as described earlier.(5) These evaluations were performed preoperatively and at 1, 3, 6, 12, and 24 months after the operation.”
MethodAmis, A., & Dawkins, G. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b2.2005151 · Cited by 731
Abnormal Rotational Knee Motion during Running after Anterior Cruciate Ligament Reconstruction
Tashman, S., Collon, D., Anderson, K., Kolowich, P., & Anderst, W. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503261709 · Cited by 722 · cited 1×
“An ACL reconstruction using the single-bundle technique does not restore knee kinematics to normal during everyday activities such as running.(28) This can have 2 possible adverse effects compared with double-bundle reconstruction.”
BackgroundLoh, J. C., Fukuda, Y., Tsuda, E., Steadman, R. J., Fu, F. H., & Woo, S. L.-Y. (2003) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2003.50084 · Cited by 706 · cited 1×
“With the single-bundle technique, placing the femoral tunnel more laterally (closer to the PL bundle origin) results in better resistance against rotational load, but at high flexion angles, reconstruction of the PL bundle alone is not sufficient in resisting anterior tibial translation.(18) Also, it has been shown in…”
ResultDistribution of in situ forces in the anterior cruciate ligament in response to rotatory loads
Gabriel, M. T., Wong, E. K., Woo, S. L., Yagi, M., & Debski, R. E. (2004) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00133-5 · Cited by 673 · cited 1×
“A recent biomechanical study proved further that the PL bundle plays a significant role in the stabilization of the knee against a combined rotational load.(8) Standard singlebundle ACL reconstructions are successful in restoring anterior stability to the knee, but not the rotational stability, the deficit of which is…”
BackgroundCurrent Trends in Anterior Cruciate Ligament Reconstruction
Fu, F. H., Bennett, C. H., Lattermann, C., & Ma, C. B. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270062501 · Cited by 564
Woo, S. L., Kanamori, A., Zeminski, J., Yagi, M., Papageorgiou, C. D., & Fu, F. H. (2002) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200206000-00003 · Cited by 538
Cited by
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Meredick, R. B., Vance, K. J., Appleby, D., & Lubowitz, J. H. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546508317964 · Cited by 348
Hussein, M., van Eck, C. F., Cretnik, A., Dinevski, D., & Fu, F. H. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546511426416 · Cited by 327
A systematic review of the femoral origin and tibial insertion morphology of the ACL
Kopf, S., Musahl, V., Tashman, S., Szczodry, M., Shen, W., & Fu, F. H. (2009) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-008-0709-5 · Cited by 268
Pivot shift as an outcome measure for ACL reconstruction: a systematic review
Ayeni, O. R., Chahal, M., Tran, M. N., & Sprague, S. (2012) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1860-y · Cited by 244
“[28] Yes No 3”
van Eck, C. F., Schreiber, V. M., Mejia, H. A., Samuelsson, K., van Dijk, C. N., Karlsson, J., & Fu, F. H. (2010) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2010.03.005 · Cited by 172
Metadata
- Authors
- Järvelä, T., Moisala, A.-S., Sihvonen, R., Järvelä, S., Kannus, P., & Järvinen, M.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2007-10-16
- Volume
- 36
- Issue
- 2
- Pages
- 290-297
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2088946530
- Cited by
- 184
- References
- 28
- FWCI
- 15.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.